Graco 258865, 258859 important safety instructions Ti15425a Ti15491a

Page 14

6.Disconnect trigger lock and trigger sprayer for approximately 15 seconds. Engage trigger lock.

Shutdown and Cleaning

10.Engage trigger lock and put prime/relief valve UP to release pressure.

ti14994a

7.Discard contaminated fluid and refill with appropri- ate flushing fluid.

8.Disengage trigger lock, reverse tip to UNCLOG position, and pull trigger for 5 seconds to prime sprayer.

ti14994a

11.Remove material cup and discard used fluid.

12.Use a soft brush to clean the black rubber inlet seal. If the vent holes become clogged, use the Fine Fin- ish optimizer cleaning tool or a paper clip to clear the holes.

ti14995a

9.Put prime/relief valve DOWN to spray position. Trigger sprayer into waste area until no paint appears in water or flushing fluid.

ti15425a

ti15491a

To avoid serious injury or damage to equipment, do not expose the sprayer electronics to flushing solvents. Keep sprayer at least 10 in. above the rim of the con- tainer when flushing.

ti15529a

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.

13.Remove Spray Tip/Guard Assembly and clean with water or flushing fluid. A soft brush can be used to loosen and remove dried material if needed.

ti15003a

NOTICE

The tip is permanently attached to the guard. Removing the tip from the guard will result in damage to the tip assembly.

14.Replace tip assembly.

15.If you used the Fine-Finish Optimizer, remove and clean optimizer with water (or flushing fluid) and a brush. Reconnect intake tube.

14

3A0153E

Image 14 Contents
ProShot Cordless Paint Sprayer Table of Contents Fire and Explosion Hazard Battery Hazard Component Identification Fb FaPrime/Relief Valve Position Pressure Relief ProcedureTrigger Lock Trigger Locked Trigger Unlocked Red ring is visibleSprayer Status Indicator Charging the BatteryCharger Status Indicator Lights Standard Suction Tube sprays ceilings and walls SetupSuction Tube Selection Cleanup/Storage Sprayer SetupInstallation Spraying Stains or Clear Coats Fine-Finish OptimizerPriming Method page 18 and/or Inlet Valve MaterialsStarting a New Job or Refilling the Cup Aiming Sprayer Reversible Tip Selection ChartTriggering Sprayer Unclogging Spray Tip/Guard Assembly Keep spray area well-ventilated. Keep a good supply Shutdown and CleaningFlushing Sprayer Ti15425a Ti15491a Tips Cleaning Sprayer ExteriorStorage Replacement Parts and Kits Part DescriptionOutlet Valve Fitting InstallationProShot Repair Kit RemovalAlternate Priming Method Inlet Valve Cleaning Troubleshooting Problem Cause SolutionReplace tip. See Install Tip/Guard Assembly Spray Pattern Diagnostics Problem Cause SolutionSee Unclogging Tip/Guard Assembly, Spray pattern spits at Technical Data 258865 258859Graco Standard Warranty Graco Information
Related manuals
Manual 24 pages 46.42 Kb