Materials

Use only water-based or oil-based (mineral spirit-type) materials with flash point greater than 100° F (38° C). Do not use materials which state “FLAMMABLE” on the packaging. For more information about your material, request MSDS from distributor or retailer.

Spraying certain materials may cause static build-up in the sprayer that can result in static shock to the user. If this occurs, first ensure the mate- rial has a flash point greater than 100° F (38° C) and does not state that it is FLAMMABLE anywhere on the package. If still feeling a static shock, the material likely contains a non-mineral spirits fluid such as, but not lim- ited to, xylene, toluene, or naphtha, which can build up static. Switch to an alternative material.

Use oil-based material outdoors or in a well-ventilated indoor area with a flow of fresh air.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.

When spraying water-basedmaterials, flush the sprayer thoroughly with water.

When spraying non-water-basedmaterials, flush the sprayer thoroughly with mineral spirits or com- patible, oil-based flushing fluid.

Starting a New Job (or Refilling the Cup)

1.Engage trigger lock and put prime/relief valve UP to release pressure.

Setup

2.Use the Fine-Finish Optimizer cleaning tool to lightly push on inlet valve to make sure it moves up and down freely.

3.Install material cup liner, fill with material, and thread onto sprayer.

ti15474a

4.To prime pump, disengage trigger lock and trigger sprayer for 10 seconds. Then release trigger and put prime/relief valve DOWN to spray position.

ti14995a

5.Reverse spray tip to UNCLOG position and spray into waste area for five seconds. Then rotate tip back to SPRAY position. NOTE: Failure to perform this operation could result in poor spray pattern.

ti15491ati14985a

ti14994a

ti14999a

NOTE: If sprayer fails to prime, follow Alternative

Priming Method (page 18) and/or Inlet Valve

Cleaning (page 19).

10

3A0153E

Image 10
Contents ProShot Cordless Paint Sprayer Table of Contents Fire and Explosion Hazard Battery Hazard Component Identification Fb FaPrime/Relief Valve Position Pressure Relief ProcedureTrigger Lock Trigger Locked Trigger Unlocked Red ring is visibleCharger Status Indicator Lights Charging the BatterySprayer Status Indicator Suction Tube Selection SetupStandard Suction Tube sprays ceilings and walls Cleanup/Storage Sprayer SetupInstallation Spraying Stains or Clear Coats Fine-Finish OptimizerStarting a New Job or Refilling the Cup MaterialsPriming Method page 18 and/or Inlet Valve Triggering Sprayer Reversible Tip Selection ChartAiming Sprayer Unclogging Spray Tip/Guard Assembly Flushing Sprayer Shutdown and CleaningKeep spray area well-ventilated. Keep a good supply Ti15425a Ti15491a Storage Cleaning Sprayer ExteriorTips Replacement Parts and Kits Part DescriptionOutlet Valve Fitting InstallationProShot Repair Kit RemovalAlternate Priming Method Inlet Valve Cleaning Troubleshooting Problem Cause SolutionSee Unclogging Tip/Guard Assembly, Spray Pattern Diagnostics Problem Cause SolutionReplace tip. See Install Tip/Guard Assembly Spray pattern spits at Technical Data 258865 258859Graco Standard Warranty Graco Information