Alternate Priming Method
1.Engage trigger lock and put prime/relief valve UP to release pressure.
Alternate Priming Method
4.Hold sprayer above sink or waste area, disengage the trigger lock, and quickly trigger sprayer until material comes out of the drain tube.
ti14994a | ti14999a |
2. Remove material cup and fill with flushing material.
3.With sprayer in prime mode, turn sprayer
NOTE: Material can shoot out of the drain tube when performing this procedure. Be sure to wear appropriate safety equipment and point drain tube away from yourself when pulling the trigger,
5. Thread the material cup back onto sprayer.
6.Trigger the gun for 10 seconds then release the trig- ger and put the prime/relief valve DOWN to spray position.
7.Reverse spray tip to UNCLOG position and spray into waste area for five seconds to ensure sprayer has primed.
ti14991a
8.Sprayer is now ready to spray. Follow Starting New Job instructions on page 10.
18 | 3A0153E |