Graco 258865, 258859 important safety instructions Alternate Priming Method

Page 18

Alternate Priming Method

1.Engage trigger lock and put prime/relief valve UP to release pressure.

Alternate Priming Method

4.Hold sprayer above sink or waste area, disengage the trigger lock, and quickly trigger sprayer until material comes out of the drain tube.

ti14994a

ti14999a

2. Remove material cup and fill with flushing material.

3.With sprayer in prime mode, turn sprayer upside-down, remove strainer and slowly pour flush- ing material into the intake tube until full.

NOTE: Material can shoot out of the drain tube when performing this procedure. Be sure to wear appropriate safety equipment and point drain tube away from yourself when pulling the trigger,

5. Thread the material cup back onto sprayer.

6.Trigger the gun for 10 seconds then release the trig- ger and put the prime/relief valve DOWN to spray position.

7.Reverse spray tip to UNCLOG position and spray into waste area for five seconds to ensure sprayer has primed.

ti14991a

8.Sprayer is now ready to spray. Follow Starting New Job instructions on page 10.

18

3A0153E

Image 18
Contents ProShot Cordless Paint Sprayer Table of Contents Fire and Explosion Hazard Battery Hazard Component Identification Fb FaPrime/Relief Valve Position Pressure Relief ProcedureTrigger Lock Trigger Locked Trigger Unlocked Red ring is visibleCharging the Battery Charger Status Indicator LightsSprayer Status Indicator Setup Suction Tube SelectionStandard Suction Tube sprays ceilings and walls Cleanup/Storage Sprayer SetupInstallation Spraying Stains or Clear Coats Fine-Finish OptimizerMaterials Starting a New Job or Refilling the CupPriming Method page 18 and/or Inlet Valve Reversible Tip Selection Chart Triggering SprayerAiming Sprayer Unclogging Spray Tip/Guard Assembly Shutdown and Cleaning Flushing SprayerKeep spray area well-ventilated. Keep a good supply Ti15425a Ti15491a Cleaning Sprayer Exterior StorageTips Replacement Parts and Kits Part DescriptionOutlet Valve Fitting InstallationProShot Repair Kit RemovalAlternate Priming Method Inlet Valve Cleaning Troubleshooting Problem Cause SolutionSpray Pattern Diagnostics Problem Cause Solution See Unclogging Tip/Guard Assembly,Replace tip. See Install Tip/Guard Assembly Spray pattern spits at Technical Data 258865 258859Graco Standard Warranty Graco Information