Graco 258865, 258859 Pressure Relief Procedure, Trigger Lock, Prime/Relief Valve Position

Page 6

Common Procedures

Common Procedures

Pressure Relief Procedure

Spray Tip Position

 

 

 

 

 

 

 

 

Do not operate or spray near children. Do not aim the sprayer at, or spray any person or animal. Keep hands and other body parts away from the front of the sprayer. For example, do not try to stop the paint flow with any part of the body.

This sprayer builds up an internal pressure of 2,000 psi during use. Follow this Pressure Relief Procedure whenever you stop spraying and before cleaning, checking, servicing, or transporting equipment to prevent serious injury.

1. Engage trigger lock.

2. Put prime/relief valve UP to release pressure.

ti14999a

Trigger Lock

Always perform Pressure Relief Procedure before adjusting spray tip position.

ti14985a

ti14991a

Tip Forward

Tip Reversed

(SPRAY position)

(UNCLOG position)

Prime/Relief Valve Position

ti14999a

 

ti15425a

UP position

DOWN position

(Releases pump pressure)

(Ready to spray)

Always engage the trigger lock when you stop spraying to prevent the sprayer from being triggered accidentally by hand, or if dropped or bumped.

ti14994a

 

ti14995a

Trigger Locked

Trigger Unlocked

 

(red ring is visible)

6

3A0153E

Image 6
Contents ProShot Cordless Paint Sprayer Table of Contents Fire and Explosion Hazard Battery Hazard Component Identification Fb FaPrime/Relief Valve Position Pressure Relief ProcedureTrigger Lock Trigger Locked Trigger Unlocked Red ring is visibleCharging the Battery Charger Status Indicator LightsSprayer Status Indicator Setup Suction Tube SelectionStandard Suction Tube sprays ceilings and walls Cleanup/Storage Sprayer SetupInstallation Spraying Stains or Clear Coats Fine-Finish OptimizerMaterials Starting a New Job or Refilling the CupPriming Method page 18 and/or Inlet Valve Reversible Tip Selection Chart Triggering SprayerAiming Sprayer Unclogging Spray Tip/Guard Assembly Shutdown and Cleaning Flushing SprayerKeep spray area well-ventilated. Keep a good supply Ti15425a Ti15491a Cleaning Sprayer Exterior StorageTips Replacement Parts and Kits Part DescriptionOutlet Valve Fitting InstallationProShot Repair Kit RemovalAlternate Priming Method Inlet Valve Cleaning Troubleshooting Problem Cause SolutionSpray Pattern Diagnostics Problem Cause Solution See Unclogging Tip/Guard Assembly,Replace tip. See Install Tip/Guard Assembly Spray pattern spits at Technical Data 258865 258859Graco Standard Warranty Graco Information