Graco 258859, 258865 important safety instructions Inlet Valve Cleaning

Page 19

Alternate Priming Method

Inlet Valve Cleaning

Removal

1.Engage trigger lock and pull relief valve UP to release pressure.

ti14994a

ti14999a

2. Remove material cup and suction tube.

3.Hold sprayer upside-down and use wrench or socket to loosen and remove inlet fitting, inlet valve, and spring.

ti15505a

NOTE: Make sure the spring also comes out. Use needle-nose pliers to remove if needed. Inlet cavity should be completely empty (as shown below).

ti15530a

4.Clean as much excess material from pump cavity as possible. Make sure you also clean spring (a), o-ring (c), and top of inlet fitting (d).

Installation

NOTE: Before installing, make sure o-ring (c) is installed on inlet valve (b).

1.Place inlet valve (b) with spring (a) on top of inlet fit- ting (d). Push inlet fitting up into pump cavity.

a

b c

d

ti15502a

2.Hold inlet in place and turn sprayer upside-down. Remove inlet fitting and visually check to see that inlet valve has seated correctly.

ti15500a

3.Replace inlet fitting and use wrench and socket to tighten to 10 ft-lb.

NOTICE

Do NOT over-tighten inlet fitting. Damage to the equipment will occur.

4.Use the Fine-Finish Optimizer cleaning tool to lightly push on inlet valve to make sure it moves up and down freely.

3A0153E

19

Image 19
Contents ProShot Cordless Paint Sprayer Table of Contents Fire and Explosion Hazard Battery Hazard Fb Fa Component IdentificationTrigger Locked Trigger Unlocked Red ring is visible Pressure Relief ProcedureTrigger Lock Prime/Relief Valve PositionCharger Status Indicator Lights Charging the BatterySprayer Status Indicator Suction Tube Selection SetupStandard Suction Tube sprays ceilings and walls Spraying Stains or Clear Coats Fine-Finish Optimizer Sprayer SetupInstallation Cleanup/StorageStarting a New Job or Refilling the Cup MaterialsPriming Method page 18 and/or Inlet Valve Triggering Sprayer Reversible Tip Selection ChartAiming Sprayer Unclogging Spray Tip/Guard Assembly Flushing Sprayer Shutdown and CleaningKeep spray area well-ventilated. Keep a good supply Ti15425a Ti15491a Storage Cleaning Sprayer ExteriorTips Part Description Replacement Parts and KitsRemoval InstallationProShot Repair Kit Outlet Valve FittingAlternate Priming Method Inlet Valve Cleaning Problem Cause Solution TroubleshootingSee Unclogging Tip/Guard Assembly, Spray Pattern Diagnostics Problem Cause SolutionReplace tip. See Install Tip/Guard Assembly Spray pattern spits at 258865 258859 Technical DataGraco Information Graco Standard Warranty