Removal

1.Engage trigger lock and pull relief valve UP to release pressure.

ti14994a

ti14999a

2. Remove battery.

ti14996a

3. Remove pump outlet cap.

4.Use tool (supplied) to loosen and remove outlet valve fitting.

ti15506a

Installation

1.Screw outlet valve fitting into threads. Use tool (sup- plied) and tighten to 8 ft-lb.

ti15508a

2. Press new pump outlet cap into place.

3A0153E

17

Image 17
Contents ProShot Cordless Paint Sprayer Table of Contents Fire and Explosion Hazard Battery Hazard Fb Fa Component IdentificationTrigger Lock Pressure Relief ProcedurePrime/Relief Valve Position Trigger Locked Trigger Unlocked Red ring is visibleSprayer Status Indicator Charging the BatteryCharger Status Indicator Lights Standard Suction Tube sprays ceilings and walls SetupSuction Tube Selection Installation Sprayer SetupCleanup/Storage Spraying Stains or Clear Coats Fine-Finish OptimizerPriming Method page 18 and/or Inlet Valve MaterialsStarting a New Job or Refilling the Cup Aiming Sprayer Reversible Tip Selection ChartTriggering Sprayer Unclogging Spray Tip/Guard Assembly Keep spray area well-ventilated. Keep a good supply Shutdown and CleaningFlushing Sprayer Ti15425a Ti15491a Tips Cleaning Sprayer ExteriorStorage Part Description Replacement Parts and KitsProShot Repair Kit InstallationOutlet Valve Fitting RemovalAlternate Priming Method Inlet Valve Cleaning Problem Cause Solution TroubleshootingReplace tip. See Install Tip/Guard Assembly Spray Pattern Diagnostics Problem Cause SolutionSee Unclogging Tip/Guard Assembly, Spray pattern spits at 258865 258859 Technical DataGraco Information Graco Standard Warranty