Connect Fluid Hose

NOTE:

Before connecting the fluid line, blow it out with air and flush it with solvent. Use solvent that is compatible with the fluid to be sprayed.

Install a fluid regulator (L) on the fluid line to control fluid pressure to the gun. See FIG. 8.

Install a fluid shutoff valve (M) to shut off the fluid supply to the gun.

Filter the fluid line of coarse particles and sediment to avoid clogging the fluid nozzle and causing finishing defects. Inline fluid filter 24B707 is available.

K

L

M

J

ti7016a

FIG. 8: Connect Fluid Hose.

1.Connect the fluid supply hose (J) to the gun fluid inlet (S), 6 mm OD tube fitting. See FIG. 9.

2.Connect the other end of the fluid hose (J) to a regulated fluid supply outlet (M).

3.In a circulating system, connect a grounded fluid return hose to the gun fluid outlet (T). See FIG. 9.

Setup

In a non-circulating system, remove the gun fluid outlet fitting (T) and plug the outlet port with the pipe plug (33) supplied for guns without manifold. Guns with manifold use plug 24C211 (25, see page 10).

KEY

N Cylinder Air Inlet: accepts 6 mm OD tubing

P Atomization Air Inlet: 6 mm OD tubing

R Fan Air Inlet: 6 mm OD tubing

S Fluid Inlet: 6 mm OD tubing

T Fluid Outlet (circulating gun only): 6 mm OD tubing

With Manifold

N

RP

T (or S)

S (or T)

 

TI14436A

Without Manifold

 

T (or S)

S (or T)

PR

N

TI14437A

FIG. 9: Air and Fluid Ports

313869B

15

Image 15
Contents AirPro EFX Automatic Spray Gun Important Safety InstructionsModels ContentsFire and Explosion Hazard Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Selection Charts Gun SelectionProper Needle/Nozzle Selection Models Without Manifolds Models With ManifoldsNeedle Assembly Identification Air CapsSample Pattern Sizes and Shapes 313869B Guns with Manifold InstallationVentilate Spray Booth Configure Gun and ManifoldGuns without Manifold Ground SystemMount Gun Reciprocating Arm Rod MountStationary Support Connect Air Line SetupAir regulator Connect Fluid Hose With ManifoldWithout Manifold Vertical Pattern Horizontal Pattern Flush Spray Gun Adjust Spray PatternPerform Pressure Relief Procedure, Position Air CapFluid Pressure Regulator Suggested Starting Settings Spray Fan Air Atomizing AirIncorrect Pressure Relief ProcedureOperation Apply FluidDaily Gun Care General System Maintenance Clean and Flush GunFollow the Pressure Relief Procedure, 313869B Wrong TroubleshootingProblem Cause Solution Disassembly ServiceReassembly Parts Guns with ManifoldGuns without Manifold Additional Parts for Models with Manifold Parts in CommonRepair Kits AccessoriesDimensions Mounting Hole Layouts 44.7 mm M8 x 1.25 T 35 in .9 mm deep 24.1 mm Slot Triggering Speed Technical DataAir Brush Sound DataConventional HiTEchAir Flow Spray Pattern Test Report Spray Pattern Test ReportGraco Information Graco Standard Warranty