Graco Inc TI14427A, 313869B, TI14428A Flush Spray Gun Adjust Spray Pattern, Position Air Cap

Page 16

Setup

Flush Spray Gun

 

 

 

Adjust Spray Pattern

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Before running any paint through the spray gun:

1.Flush the gun with a solvent that is compat- ible with the fluid to be sprayed, using the lowest possible fluid pressure and a grounded metal container. See Clean and Flush Gun, page 20.

2.Perform Pressure Relief Procedure, page 18.

Position Air Cap

Air caps are factory-set with the alignment pin

(A)set to a vertical spray pattern. To change the air cap to a horizontal spray pattern, use a 1/16 in. hex wrench to unscrew the alignment pin (A) and relocate it to the horizontal spray pattern hole. When relocating the pin use low strength thread locker. Torque to 1.5-2.5 in-lb (0.2-0.3 N•m). Do not overtighten. Refer to FIG. 10.

A

ti8171a

Vertical Pattern

A

Horizontal Pattern

ti8170a

ti8172a

FIG. 10: Position Air Cap

Do not exceed 100 psi (0.7 MPa, 7 bar) maximum fluid and air pressure. Higher pressures can cause parts to rupture and result in serious injury.

Use the fluid pressure regulator to adjust the spray gun fluid flow. All models are equipped with a fluid control knob to make precise fluid flow adjustments.

Follow these steps to establish the correct fluid flow and air flow:

1.To achieve desired flow, adjust the fluid flow using the fluid pressure regulator (L) installed in the gun fluid line. Typical indus- trial flow rates will vary with regulator pres- sures from 5 to 30 psi (34 to 210 kPa,

0.3 to 2.1 bar). If the fluid pressure is too low at the desired flow rate, install a smaller nozzle. If the fluid pressure is too high, install a larger nozzle.

For spray guns equipped with the fluid con- trol knob, you can make flow rate changes at the spray gun. Rotate the fluid control knob clockwise to reduce the flow.

16

313869B

Image 16
Contents Important Safety Instructions AirPro EFX Automatic Spray GunContents ModelsFire and Explosion Hazard Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Gun Selection Selection ChartsProper Needle/Nozzle Selection Models With Manifolds Models Without ManifoldsAir Caps Needle Assembly IdentificationSample Pattern Sizes and Shapes 313869B Installation Ventilate Spray BoothConfigure Gun and Manifold Guns with ManifoldGround System Guns without ManifoldReciprocating Arm Rod Mount Mount GunStationary Support Setup Connect Air LineAir regulator With Manifold Connect Fluid HoseWithout Manifold Flush Spray Gun Adjust Spray Pattern Perform Pressure Relief Procedure,Position Air Cap Vertical Pattern Horizontal PatternSuggested Starting Settings Spray Fan Air Atomizing Air Fluid Pressure RegulatorPressure Relief Procedure OperationApply Fluid IncorrectDaily Gun Care Clean and Flush Gun General System MaintenanceFollow the Pressure Relief Procedure, 313869B Troubleshooting WrongProblem Cause Solution Service DisassemblyReassembly Guns with Manifold PartsGuns without Manifold Parts in Common Additional Parts for Models with ManifoldAccessories Repair KitsDimensions Mounting Hole Layouts 44.7 mm M8 x 1.25 T 35 in .9 mm deep 24.1 mm Slot Technical Data Triggering SpeedSound Data ConventionalHiTEch Air BrushAir Flow Spray Pattern Test Report Spray Pattern Test ReportGraco Standard Warranty Graco Information