Operation

General System Maintenance

Follow the Pressure Relief Procedure, page 18.

Clean the fluid and air line filters daily.

Check for any fluid leakage from the gun and fluid hoses. Tighten fittings or replace equipment as needed.

Flush the gun before changing colors and whenever you are done operating the gun.

Clean and Flush Gun

1.Follow the Pressure Relief Procedure, page 18.

2.Shut off the gun fan and atomizing air.

3.Supply a compatible solvent to the gun fluid inlet.

4.Point the gun down into a grounded metal container, and flush the gun with solvent until all traces of paint are removed from the gun passages.

5.Follow the Pressure Relief Procedure, page 18.

6.Disconnect the solvent supply.

7.Remove the air cap retaining ring and air cap.

NOTICE

Trigger the gun whenever you tighten or remove the nozzle. This keeps the needle seat away from the nozzle seating surface and prevents the seat from being dam- aged.

8.Clean the air cap retaining ring, air cap, and fluid nozzle with solvent.

9.Dip the end of a soft-bristle brush into a compatible solvent. Do not continuously soak the brush's bristles with solvent and do not use a wire brush.

ti4845a

FIG. 15: Use solvent-dipped soft-bristle brush

10.With the gun pointed down, clean the front of the gun, using the soft-bristle brush and solvent.

11.Scrub the air cap retaining ring, air cap, and fluid nozzle with the soft-bristle brush (see FIG. 16). To clean out air cap holes, use a soft implement, such as a toothpick, to avoid damaging critical surfaces. Clean the air cap and fluid nozzle daily, minimum. Some applications require more frequent cleaning.

ti8176a

FIG. 16: Clean air cap, ring and fluid nozzle

12.Install the air cap retaining ring and air cap.

13.Dampen a soft cloth with solvent and wring out the excess. Point the gun down and wipe off the outside of the gun.

20

313869B

Image 20
Contents Important Safety Instructions AirPro EFX Automatic Spray GunContents ModelsFire and Explosion Hazard Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Proper Needle/Nozzle Selection Selection ChartsGun Selection Models With Manifolds Models Without ManifoldsSample Pattern Sizes and Shapes Needle Assembly IdentificationAir Caps 313869B Installation Ventilate Spray BoothConfigure Gun and Manifold Guns with ManifoldGround System Guns without ManifoldStationary Support Mount GunReciprocating Arm Rod Mount Setup Connect Air LineAir regulator Without Manifold Connect Fluid HoseWith Manifold Flush Spray Gun Adjust Spray Pattern Perform Pressure Relief Procedure,Position Air Cap Vertical Pattern Horizontal PatternSuggested Starting Settings Spray Fan Air Atomizing Air Fluid Pressure RegulatorPressure Relief Procedure OperationApply Fluid IncorrectDaily Gun Care Follow the Pressure Relief Procedure, General System MaintenanceClean and Flush Gun 313869B Troubleshooting WrongProblem Cause Solution Service DisassemblyReassembly Guns without Manifold PartsGuns with Manifold Parts in Common Additional Parts for Models with ManifoldAccessories Repair KitsDimensions Mounting Hole Layouts 44.7 mm M8 x 1.25 T 35 in .9 mm deep 24.1 mm Slot Technical Data Triggering SpeedSound Data ConventionalHiTEch Air BrushAir Flow Spray Pattern Test Report Spray Pattern Test ReportGraco Standard Warranty Graco Information