Graco Inc TI14428A, 313869B, TI14427A Suggested Starting Settings Spray Fan Air Atomizing Air

Page 17

Setup

NOTE: HVLP Gun Limits

HVLP Guns: local laws may limit the maximum pressure to 10 psi (70 kPa, 0.7 bar) at the air cap for compliance. See the table on page 8 for maximum HVLP manifold inlet pressures. To measure pressure at the air cap, use the appropriate HVLP Pressure Verification Kit.

L

ti7019a

FIG. 11: Fluid Pressure Regulator

NOTE: A larger fluid nozzle at a reduced fluid pressure will maintain the same flow rate, but the fluid stream (velocity) will slow down.

When air is applied, the lower velocity allows the air to act on the fluid longer, which improves atomization.

2.Using the air pressure regulator (F), set the fan and atomizing air supply pressure per Table 1. Use these suggested settings as a starting point.

Table 1: Suggested Starting Settings

Spray

Fan Air

Atomizing Air

Type

psi (MPa, bar)

psi (MPa, bar)

 

 

 

Conven-

43 (0.3, 3.0)

43 (0.3, 3.0)

tional

 

 

 

 

 

HVLP

15 (0.1, 1.0)

15 (0.1, 1.0)

 

 

 

HiTEch

29 (0.2, 2.0)

29 (0.2, 2.0)

 

 

 

LVMP

43 (0.3, 3.0)

43 (0.3, 3.0)

 

 

 

Air Brush

NA

29 (0.2, 2.0)

 

 

 

F

ti01997

FIG. 12: Air Pressure Regulator

3.Test the spray pattern atomization while keeping the gun a consistent distance, about 6 to 8 inches (150 to 200 mm), from the test piece.

Check the atomization quality. Increase the gun atomizing air supply pressure with the air pressure regulator in 5 psi (34 kPa, 0.3 bar) increments until you obtain the desired atomization.

NOTE: For the best transfer efficiency, use the lowest setting needed to achieve desired finish quality.

4.If the spray pattern is too wide or split, reduce the fan air pressure.

NOTE: Reducing the fan air pressure to 0 psi (or fully closing the fan adjustment valve) will produce a round pattern.

To further control the spray pattern, use an alternate air cap. For a list of available air caps, see page 8.

313869B

17

Image 17
Contents AirPro EFX Automatic Spray Gun Important Safety InstructionsModels ContentsFire and Explosion Hazard Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Proper Needle/Nozzle Selection Selection ChartsGun Selection Models Without Manifolds Models With ManifoldsSample Pattern Sizes and Shapes Needle Assembly IdentificationAir Caps 313869B Ventilate Spray Booth InstallationConfigure Gun and Manifold Guns with ManifoldGuns without Manifold Ground SystemStationary Support Mount GunReciprocating Arm Rod Mount Connect Air Line SetupAir regulator Without Manifold Connect Fluid HoseWith Manifold Perform Pressure Relief Procedure, Flush Spray Gun Adjust Spray PatternPosition Air Cap Vertical Pattern Horizontal PatternFluid Pressure Regulator Suggested Starting Settings Spray Fan Air Atomizing AirOperation Pressure Relief ProcedureApply Fluid IncorrectDaily Gun Care Follow the Pressure Relief Procedure, General System MaintenanceClean and Flush Gun 313869B Wrong TroubleshootingProblem Cause Solution Disassembly ServiceReassembly Guns without Manifold PartsGuns with Manifold Additional Parts for Models with Manifold Parts in CommonRepair Kits AccessoriesDimensions Mounting Hole Layouts 44.7 mm M8 x 1.25 T 35 in .9 mm deep 24.1 mm Slot Triggering Speed Technical DataConventional Sound DataHiTEch Air BrushAir Flow Spray Pattern Test Report Spray Pattern Test ReportGraco Information Graco Standard Warranty