Graco Inc TI14427A, 313869B, TI14428A important safety instructions Daily Gun Care

Page 19

Operation

Daily Gun Care

NOTICE

Methylene chloride with formic or propionic acid is not recommended as a flushing or cleaning solvent with this gun as it will damage aluminum and nylon components.

NOTICE

Solvent left in gun air passages could result in a poor quality paint finish. Do not use any cleaning method which may allow solvent into the gun air passages.

Do not wipe the gun with a cloth soaked

Do not point the gun up while cleaning it. in solvent; wring out the excess.

ti8100a

Do not immerse the gun in solvent.

ti4827a

Do not use metal tools to clean the air cap holes as this may scratch them; scratches can distort the spray pattern.

ti8101a

ti8175a

313869B

19

Image 19
Contents AirPro EFX Automatic Spray Gun Important Safety InstructionsModels ContentsFire and Explosion Hazard Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Gun Selection Selection ChartsProper Needle/Nozzle Selection Models Without Manifolds Models With ManifoldsAir Caps Needle Assembly IdentificationSample Pattern Sizes and Shapes 313869B Guns with Manifold InstallationVentilate Spray Booth Configure Gun and ManifoldGuns without Manifold Ground SystemReciprocating Arm Rod Mount Mount GunStationary Support Connect Air Line SetupAir regulator With Manifold Connect Fluid HoseWithout Manifold Vertical Pattern Horizontal Pattern Flush Spray Gun Adjust Spray PatternPerform Pressure Relief Procedure, Position Air CapFluid Pressure Regulator Suggested Starting Settings Spray Fan Air Atomizing AirIncorrect Pressure Relief ProcedureOperation Apply FluidDaily Gun Care Clean and Flush Gun General System MaintenanceFollow the Pressure Relief Procedure, 313869B Wrong TroubleshootingProblem Cause Solution Disassembly ServiceReassembly Guns with Manifold PartsGuns without Manifold Additional Parts for Models with Manifold Parts in CommonRepair Kits AccessoriesDimensions Mounting Hole Layouts 44.7 mm M8 x 1.25 T 35 in .9 mm deep 24.1 mm Slot Triggering Speed Technical DataAir Brush Sound DataConventional HiTEchAir Flow Spray Pattern Test Report Spray Pattern Test ReportGraco Information Graco Standard Warranty