Graco Inc TI14428A, 313869B, TI14427A important safety instructions Problem Cause Solution

Page 23

 

 

Troubleshooting

 

 

 

Problem

Cause

Solution

 

 

 

 

 

 

Gun spitting.

Air getting into paint stream.

Check if fluid source is empty

 

 

and fill.

 

 

Tighten fluid nozzle (4).

 

 

Check fluid nozzle o-ring (3) for

 

 

damage.

 

 

Check fluid nozzle (4) for dam-

 

 

age.

 

 

 

Will not spray.

Fluid control valve (11) turned

Adjust fluid control valve (11)

 

too far clockwise.

counterclockwise.

 

 

 

 

Fluid source empty.

Refill.

 

 

 

Excessive air blowing back.

Loose fluid nozzle (4).

Tighten fluid nozzle (4).

 

 

 

 

Damaged fluid nozzle seal (3).

Replace seal (3).

 

 

 

Gun fluid pressure is too high

Using needle/nozzle kit with

Use needle/nozzle kit with

with gun triggered (cannot

too small orifice.

larger orifice.

achieve desired flow rate).

 

 

 

 

 

Using a low fluid pressure set-

Using needle/nozzle kit with

Use needle/nozzle kit with

ting, the fluid flow is too high,

too large orifice.

smaller orifice.

making it necessary to restrict

 

 

needle travel to reduce fluid

 

 

flow.

 

 

 

 

 

Fluid system will not operate at

There is no fluid regulator, or

Add low pressure fluid regula-

low enough pressure [below

air regulator is not sensitive

tor, or add more sensitive low

10 psi (70 kPa, 0.7 bar)].

enough at low pressure.

pressure air regulator.

 

 

 

Fluid flow is fluttering while

Fluid source empty.

Refill.

spraying.

 

 

 

 

 

313869B

23

Image 23
Contents AirPro EFX Automatic Spray Gun Important Safety InstructionsModels ContentsFire and Explosion Hazard Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Proper Needle/Nozzle Selection Selection ChartsGun Selection Models Without Manifolds Models With ManifoldsSample Pattern Sizes and Shapes Needle Assembly IdentificationAir Caps 313869B Guns with Manifold InstallationVentilate Spray Booth Configure Gun and ManifoldGuns without Manifold Ground SystemStationary Support Mount GunReciprocating Arm Rod Mount Connect Air Line SetupAir regulator Without Manifold Connect Fluid HoseWith Manifold Vertical Pattern Horizontal Pattern Flush Spray Gun Adjust Spray PatternPerform Pressure Relief Procedure, Position Air CapFluid Pressure Regulator Suggested Starting Settings Spray Fan Air Atomizing AirIncorrect Pressure Relief ProcedureOperation Apply FluidDaily Gun Care Follow the Pressure Relief Procedure, General System MaintenanceClean and Flush Gun 313869B Wrong TroubleshootingProblem Cause Solution Disassembly ServiceReassembly Guns without Manifold PartsGuns with Manifold Additional Parts for Models with Manifold Parts in CommonRepair Kits AccessoriesDimensions Mounting Hole Layouts 44.7 mm M8 x 1.25 T 35 in .9 mm deep 24.1 mm Slot Triggering Speed Technical DataAir Brush Sound DataConventional HiTEchAir Flow Spray Pattern Test Report Spray Pattern Test ReportGraco Information Graco Standard Warranty