Graco Inc 307-638, 218-026, PRO4000 manual Service, 45d, 45f, 45c

Page 21

SERVICE

5.Carefully remove the fluid needle assembly (45) from the rear part of the gun barrel (18). See Fig 15. If the packing assembly (45a) or insulator (45g) are still in the barrel, insert the packing removal rod (59d) into the front of the barrel to gently push them out. Refer to Fig 16.

NOTE: If the insulator (45g) is removed, be sure to install it so the insulator end with holes is facing the packing assembly (45a).

6.Wipe the internal surfaces of the barrel clean with a soft brush or cloth.

CAUTION

Clean all parts in non±conductive solvent compatible with the fluid being used, such as xylol or mineral spirits. Use of conductive solvents can cause the gun to malfunction.

7.Remove the packing assembly (45a) from the needle (45b).

NOTE: If the position of the adjusting nut (45c) is changed, install the adjusting nut to the approxi- mate dimension shown in Fig 15. (Final adjust- ment will be made in step 15.) If the spring (45f) was removed, reinstall it over the nut (45d).

8. Install the new packing assembly (45a).

CAUTION

Carefully screw needle (45b) into new packing assembly (45a) to avoid damaging the seals.

9.Test the drag on the fluid needle. It should be approxi- mately 2.5±3 lbs (use a small spring scale to meas- ure). If the adjustment is out of tolerance, tighten or loosen the adjusting screw on the packing assembly (45a) slightly and retest. Continue to adjust until the tolerance is correct.

10.Install the entire fluid needle assembly (45) into the gun barrel, from the back of the barrel.

11.Firmly tighten the packing nut (45e) down until it bot- toms.

CAUTION

When checking the fluid needle movement, DO NOT move the needle out of the gun barrel more than 6.35 mm (1/4 in.) to avoid pulling the needle out of the packing area and damaging the pack- ings.

12.Install the barrel as described under Barrel Removal.

13.Install the electrode as described under Electrode Replacement.

14.Install the air cap assembly and fluid nozzle as described in Clean the Air Cap and Fluid Nozzle.

15.Trigger the gun to check the needle adjustment. The air should come fully on before the fluid comes on. Adjust the needle adjusting nut (45c) until the proper lead and lag is achieved.

If the fluid comes on too soon, remove the trigger and back the needle adjusting nut (45c) out (away from the barrel) slightly.

If the fluid comes on too late, tighten the needle adjusting nut (45c) slightly (turn towards barrel).

After adjustment is complete, tighten the locking nut (45d) against the adjusting nut (45c).

KEY

18Gun Barrel

45Fluid Needle Assembly

45c Needle Adjusting Nut

132.7 mm

(5.2 in.)

45c 45

18

Fig 15

KEY

45

Fluid Needle Assembly

45d

 

 

45a

Needle Packing Assembly

 

 

45b

Fluid Needle

 

 

45c

Adjusting Nut

 

 

45d

Locking Nut

 

45f

 

45e

Packing Nut

 

 

45f

Spring

45c

 

 

45g

Insulator

 

 

45b

45e

45g45 45a

Fig 16

3￿7￿638 21

Image 21
Contents Rev. AE Manual MID±RANGE ElectrostaticPart Number 218±026, Series E Read and Retain for Reference Terms Table of ContentsHose Safety Equipment Misuse HazardHazardous Fluid Hazard Ventilate the Spray Booth Flushing and Cleaning SafetyFire or Explosion Hazard HOW the Electrostatic AIR Spray GUN WorksTypical Installation NON±HAZARDOUS Area Hazardous AreaKEY Installation Ventilate the Spray BoothConnect the Fluid Line Refer to the Typical Check the Electrical Grounding See Fig Operation Operating ChecklistFilter the Fluid Spraying OperationAdjust the Spray Pattern Install the Fluid Nozzle and Air CapDaily Care and Cleaning MaintenanceClean the Air Cap and Fluid Nozzle Follow the Pressure Relief Procedure Warning onFlush the Spray Gun Problem Cause Solution Improper Spray Pattern Spray Pattern Troubleshooting ChartProblem Cause Solution GUN Operation Troubleshooting ChartElectrical Troubleshooting Chart Test Gun Resistance Test Power Supply ResistanceTest Resistor Stud Resistance Electrode Replacement Gun DisassemblyResistor Stud Replacement Barrel Removal Fluid Needle Packing Replacement45d Service45f 45cPower Cartridge Replacement 18b3c 2 3a Turbine Alternator Removal Air Valve Replacement Fan Air Valve ReplacementFluid Adjusting Screw Replacement ES ON±OFF Valve Removal & ReplacementMuffler and Check Valve Replacement KEY81Parts Drawing Ref No Power CartridgeRef No 59, Tool Kit Includes items 59a±59h 59f 59e 59d 59g 59c 59b59a218±014 HANDLE, gun Includes item 2a Parts List179±400 18b 186±127Repair Kits Service Information Technical DataHOW to Order Replacement Parts Assembly Changed Status No. Part No NameAccessories 218±123 Electrostatic System Filter AIR or Paint 202±271218±124 Electrostatic System PRO4000H GUN Electrostatic High Conductivity KIT 222±029Important Phone Numbers Graco PRO4000 Warranty and Disclaimers