Graco Inc PRO4000, 307-638, 218-026 GUN Operation Troubleshooting Chart, Problem Cause Solution

Page 14

GUN OPERATION TROUBLESHOOTING CHART

PROBLEM

CAUSE

SOLUTION

 

 

 

 

Leakage from fluid pack-

Worn needle packing.

Replace packing assembly. See page 21.

ing nut.

 

 

 

 

 

 

 

Air leakage from front of

Air valve not seating properly.

Clean, service. See page 24.

gun.

Air stem packing too tight.

Loosen packing. See page 24.

 

 

 

Fluid leakage from

Electrode worn or damaged.

Replace electrode. See page 18.

front of gun.

Worn fluid seat.

Replace fluid nozzle and/or electrode.

 

 

See page 18.

 

Fluid packing too tight.

Adjust packing screw. See page 20.

 

Loose fluid nozzle.

Tighten fluid nozzle. See page 10.

 

Fluid adjusting screw not set correctly.

Adjust screw.

 

 

 

ªOrangePeelº finish.

Insufficient air pressure.

Increase, use least air pressure needed

 

 

for good results.

 

Fluid poorly mixed or filtered.

Remix or refilter fluid.

 

Improper thinner being used.

Use proper thinner.

 

 

 

 

Excessive spray fog.

Too much air pressure.

Reduce,use least air pressure needed

 

 

for good results.

 

Fluid thinned too much.

Properly thin fluid.

 

 

 

 

No fluid sprays from

Fluid low.

Check, add if necessary.

gun.

Damaged air cap.

Replace air cap. See page 10.

 

Dirty or clogged fluid nozzle.

Clean fluid nozzle. See page 11.

 

Damaged fluid nozzle.

Check, replace fluid nozzle. See page 10.

 

 

 

 

Equipment covered

Exhaust air flow insufficient or not directed

Check for proper CFM, check baffles and

with fluid.

properly.

direction of air flow.

 

 

 

 

Improper distance between gun and

Adjust distance to 203±305 mm (8±12 in.).

 

work piece.

 

 

 

 

 

 

Dirty air cap.

Misalignment between air cap and

Remove and clean air cap and fluid nozzle

 

fluid nozzle.

as described in Maintenance Section under

 

 

Clean the Air Cap and Fluid Nozzle,

 

 

then reinstall them.

 

 

 

 

14 ￿￿7￿6￿8

Image 14
Contents Part Number 218±026, Series E Manual MID±RANGE ElectrostaticRev. AE Read and Retain for Reference Table of Contents TermsHazardous Fluid Hazard Hose SafetyEquipment Misuse Hazard Fire or Explosion Hazard Flushing and Cleaning SafetyVentilate the Spray Booth HOW the Electrostatic AIR Spray GUN WorksKEY Typical InstallationNON±HAZARDOUS Area Hazardous Area Connect the Fluid Line Refer to the Typical InstallationVentilate the Spray Booth Check the Electrical Grounding See Fig Filter the Fluid Operating ChecklistOperation Spraying OperationInstall the Fluid Nozzle and Air Cap Adjust the Spray PatternClean the Air Cap and Fluid Nozzle MaintenanceDaily Care and Cleaning Follow the Pressure Relief Procedure Warning onFlush the Spray Gun Spray Pattern Troubleshooting Chart Problem Cause Solution Improper Spray PatternGUN Operation Troubleshooting Chart Problem Cause SolutionElectrical Troubleshooting Chart Test Power Supply Resistance Test Gun ResistanceTest Resistor Stud Resistance Gun Disassembly Electrode ReplacementResistor Stud Replacement Fluid Needle Packing Replacement Barrel Removal45f Service45d 45c3c 2 3a Power Cartridge Replacement18b Turbine Alternator Removal Fan Air Valve Replacement Air Valve ReplacementMuffler and Check Valve Replacement ES ON±OFF Valve Removal & ReplacementFluid Adjusting Screw Replacement KEY81Ref No 59, Tool Kit Ref No Power CartridgeParts Drawing Includes items 59a±59h 59f 59e 59d 59g 59c 59b59a179±400 Parts List218±014 HANDLE, gun Includes item 2a 18b 186±127Repair Kits HOW to Order Replacement Parts Technical DataService Information Assembly Changed Status No. Part No NameAccessories 218±124 Electrostatic System Filter AIR or Paint 202±271218±123 Electrostatic System PRO4000H GUN Electrostatic High Conductivity KIT 222±029Graco PRO4000 Warranty and Disclaimers Important Phone Numbers