GE manual General Description, Introduction, GEK±91584D, Vertical Drilling Motor, Type GE752

Page 2

GEK±91584D, Vertical Drilling Motor, Type GE752

GENERAL DESCRIPTION

FIG. 1. GE752 VERTICAL DRILLING MOTOR.

E±39088.

INTRODUCTION

GE752 drilling motors designed for vertical opera- tion, Fig. 1, are available in GE's UP, AUP, US and AUT series. This instruction provides inspection, mainte- nance and basic overhaul procedures for all of these motors. See Table I (page 3) for the models covered.

These motors have a ball bearing and a reinforced framehead at the commutator end to support the arma- ture shaft vertically. They also have a shaft extension at the commutator end for installation of a brake. Mounting feet are precision machined to align with the rotational ovals of the motor.

Refer to GEK±64271C for coverage of GE752 mod- els designed for horizontal operation.

GE752 motors are used by the oil and gas industry to power offshore and land±based drill rigs. Designed for vertical operation, they are d±c machines which require a nominal 750 volt d±c power source.

With suitable switching, they will operate equally well in either rotational direction. The following provides a listing of basic features.

The GE752UP and US models are of the ªShuntº class of motors which means they are separately ex- cited with shunt wound fields.

The GE752AUP and AUT models are of the ªSeriesº class of motors which means they are self excited with series wound fields.

GE752UP and AUP motors are original design mo- tors introduced in 1983. GE752US and AUT motors are Hi±Torque motors with:

1.A new shallow slot design and split conductor ar- rangement reduce heat generating eddy cur- rents. Kapton￿ insulation and new slot design allow more copper cross±section and allow the field windings and armature to operate at in- creased power levels.

2.The spiral groove commutator provides better commutator and brush cooling, better commuta- tion ability, and increased brush life.

3.An additional six exhaust openings in the motor drive end framehead and revised air flow pas- sage increases air flow and the motor's ability to transfer generated heat.

*Kapton is a registered trademark of E.I. duPont de Nemours & Co.

2

Image 2
Contents Contents Vertical Drilling Motor Type GE752GEK±91584D, Vertical Drilling Motor, Type GE752 General DescriptionIntroduction Vertical Drilling Motor, Type GE752, GEK±91584D Model DifferencesContd Model Differences DataData Contd Carbon BrushesPole Bore Diameter measured at center of pole Motors Min Max Motor Ratings Continuous Max. HP Shunt UP Special Tools Equipment Grounding InstructionsLubrication Grounding Procedures FigOverhaul Grease Tubes and Pipe PlugsBrushholders Fig Inspection MonthlyCovers, Seals, Latches Brushholder Sleeves Brush Spring PressureCreepage Band BrushesCommutator Flash RingSEMI±ANNUALLY Basic Repairs Brush ReplacementBrushholder Replacement Commutator Resurfacing InstallationBrushholder Clearance Adjustment Sanding Procedure Hand Stoning ProcedureGrinder Installation Fixture GrindingCommutator GRINDER. E±18249 Grinding ±19771ABasic Overhaul Testing Before DisassemblyAir Curing Commutator Bar±To±Bar Resistance Test DisassemblyMegohmmeter Test Armature Removal From FrameCOMMUTATOR±END Bearing Pilot Longitudinal D732922 CHG. N. E±28621D Models See , Description Puller Tools 41D731569 CHG . E±14383C Puller TOOLS. E±18155A Models US1, AUT Longitudinal D735357, CHG. A. E±37949B Models See Table Cleaning Steam CleaningBearing Inspection Vapor DegreasingAnti±Friction Bearings/Shaft Tapers/Bearing Fits ArmatureMotor Frame CommutatorArmature Shaft Inspection Armature Insulation 41D731545 CHG. F. E±18156A See Note Brushholders Lubrication of BoltsConnection Diagram 493A210 CHG . E±39092B Riser Width Creepage Band ReplacementRewinding Armature DiameterHydraulic Press Preferred Method ProcedureCommutator Tightening Torque Wrench Acceptable MethodSpin Seasoning Commutator Assembled On Armature Commutator ResurfacingTurning To Change Motor DirectionConnection Diagram 41A330278, CHG . E±38055B Connection Diagram 41A330179, CHG. A. E±37950A Raking ±4270BUsed Armature Resistance MeasurementTest After Repair Armature High Potential Test Rewound ArmatureProcedure for New Coil±Pole Assembly ReplacementCoil Installation Motor Frame Field CoilCoiled Frame Assembly 41D732353 CHG. N. E±39094A Models See , Coiled Frame Assembly 41D732345 CHG. V. E±39095A BOX Ground A1 and A2 View AT E Cables with P65 Coiled Frame Assembly 41D735440, CHG. A. E±38056B Description Magnet Frame Coiled Frame Assembly 41D735343, CHG. C. E±37951C Hardened Washer 1 1/4 Brazing Coil Terminals Gas Torch BrazingCoiled Frame Without Armature Flood Dipping Coiled FrameTest After Repair Varnish Treatment Armature ReassemblyBalancing Armature Commutator±End Bearing Armature BearingsDrive±End Bearing Figs , 35, 36 All Models Except US2, UP6, AUT2 and AUP5DRIVE±END Bearing ASSEMBLY. E±18166E DRIVE±END Bearing ASSEMBLY. E±39301 Models US2, UP6, AUT2 and AUP5DRIVE±END Bearing Assembly 41B537821, CHG. B. E±37952B Armature Assembly Into Frame Models UP and AUPCOMMUTATOR±END Bearing Assembly 41B532745 CHG. F. E±39090A COMMUTATOR-END Bearing Assembly 41B538068 CHG . E-39300 Checking Internal Clearance Brush Installation Hub Mounting HUB MountingHub Fitting Models 5GE752AUP, AUT Testing After OverhaulTesting Series Machines Ventilated 2300 cfm at 7.6 in. H2O at Commutator Chamber Testing Shunt Machines Models 5GE752UP and USMotor Operation UnventilatedLocking the Armature For Shipment Cleaning and SlushingRemoving Armature Locking Arrangement ShippingArmatures SkiddingProtection Preparation of BOXBoxing the Armature Storage Placing Into StorageRemoving from Storage Shipping BOX with Armature Less COVER. E±3784Vertical Drilling Motor, Type GE752, GEK±91584D OUTLINE, UP and AUP 41E903631 CHG. H. E±28755B Hole Grease Vent Tube Grease Tube Holes REF OUTLINE, US1, AUT 41E903745, CHG. A. E±37954B ºDº ºBº Vertical Drilling Motor, Type GE752, GEK±91584D GE Transportation Systems