GEK±91584D, Vertical Drilling Motor, Type GE752
.25 NPT FOR REGREASING
+± .25
16.82
15.53
+.000
± .010
16.656
2.25DIA. (3 HOLES) FOR LIFTING
AIR OUT
(4 CORNERS)
AIR OUT
.50±13 TAP 1.00 DEEP (8HOLES)
IMPORTANT:
THE ELECTRICAL EQUIPMENT SHOULD BE LOCATED IN A SPACE WHICH±
(1)PROVIDES SUFFICIENT ACCESSIBILITY FOR BRUSH INSPECTION.
(2)ALLOWS REMOVAL OF ALL THE BRUSHES AND PIGTAIL FASTENERS.
(3)ALLOWS MAINTENANCE PERSONNEL TO COMPLY TO THE GE MAINTENANCE INSTRUCTION SPECIAL REQUIREMENTS
+ .000
± .010
36.000
1.12
.50±13 TAP THRU (4 HOLES)
11.00
.75 |
|
|
FLAT | 8.00 | 1.12 |
|
.75 FLAT
VIEW AT ºAº
SHOWING FLANGE
WITH COVER
REMOVED10.25
F2 | GE752AUT AND US1 SHOWN IN | |
FI | MAIN VIEWS. | |
| ||
1.72 | APPROX. WEIGHT: | |
GE±752±AUT = 7035 LBS. | ||
| ||
| AIR FLOW REQUIREMENTS: | |
| 2300 CFM OF STANDARD AIR | |
| MINIMUM, 900 HP. | |
THIS AREA OF FOOT FLUSH | 2800 CFM OF STANDARD AIR | |
WITH FRAME FACE. | ||
MINIMUM, 1000 HP. | ||
BOTH SIDES | ||
|
1.12 8.00 .75 FLAT
.50±13 TAP THRU (4 HOLES)
8.00
VIEW AT ºBº | 1.12 |
SHOWING FLANGE
WITH COVER
REMOVED
.375±24 THREAD
.50±13 TAP THRU (4 HOLES)
1.12 | 8.00 | .50 |
| 1.12 | FLAT |
|
|
VIEW AT ºCº
SHOWING FLANGE
WITH COVER
REMOVED
VIEW SHOWING HYDRAULIC PUMP OFF FOR HUB BOTH ENDS
FIG. 49. OUTLINE, US1, AUT (41E903745, CHG. A). E±37954B