GE GE752 manual Removing from Storage, Shipping BOX with Armature Less COVER. E±3784

Page 72

GEK±91584D, Vertical Drilling Motor, Type GE752

examined for rust. Any rust found should be re- moved using fine abrasive paper, after the old slushing compound has been removed with min- eral spirits (GE±D5B8). Methanol should be used to remove all residue.

WARNING: Cleaning solvents may be toxic and/ or inflammable. They can cause serious or fatal injury if used without proper precautions. For safety:

1.Do not inhale solvent fumes.

2.Use solvents only in adequately ventilated areas.

3.Avoid contact of solvent with the skin.

4.Do not expose solvent to flame or sparks.

5.Observe caution statements issued by the manufacturer of the solvent.

Extreme care should be exercised not to dam- age critical machined surfaces such as the ta- pered shaft surface while removing rust. The surfaces should be reslushed with GE±D6C6A1

FIG. 47. SHIPPING BOX WITH ARMATURE,

LESS COVER. E±3784.

slush compound, Kendell Grade 5, or the equiva- lent.

4.Brushes should be removed from their holders and clamped under the spring clips to prevent corrosion of the commutator surface as a result of moisture absorption by the carbon.

5.Do not completely seal the motor, but cover ma- jor vent areas with a waterproof shipping tape. Leave enough opening so the machine can breathe ± i.e., moist air is not trapped. The inten- tion is to prevent entrance of water, dust, small animals, etc., but not to seal airtight. GE does not recommend the use of a silica gel or dehydrating agent.

6.Since the lubricant drains from the top half of bearings during storage, this area is subject to corrosion. The shaft should be rotated periodi- cally to redistribute a protective film. If stored in- side, rotate every three months. If outside, every month. Before placing the machine back into service after prolonged storage (1 year or more) bearings should be inspected and repacked with new grease meeting the recommended GE lubri- cation specification.

7.The machine should be meggered when placed into storage and periodically while in storage (3±month intervals). Keep a record of these megger readings as a rapid decrease in insula- tion resistance indicates the machine condition is deteriorating and the storage conditions inade- quate.

Before placing a stored motor back into service, refer to the applicable instruction ªRemoving Motors From Storageº.

REMOVING FROM STORAGE

Before placing a stored motor in service, perform the following:

1.Blow dust and dirt accumulation out of the wind- ings with clean, dry air.

2.Visually inspect for spring corrosion, sticking brushes in brushholders and general defects.

72

Image 72
Contents Contents Vertical Drilling Motor Type GE752General Description IntroductionGEK±91584D, Vertical Drilling Motor, Type GE752 Vertical Drilling Motor, Type GE752, GEK±91584D Model DifferencesContd Model Differences DataData Contd Carbon BrushesPole Bore Diameter measured at center of pole Motors Min Max Motor Ratings Continuous Max. HP Shunt UP Special Tools Equipment Grounding InstructionsGrounding Procedures Fig OverhaulLubrication Grease Tubes and Pipe PlugsInspection Monthly Covers, Seals, LatchesBrushholders Fig Brushholder Sleeves Brush Spring PressureBrushes CommutatorCreepage Band Flash RingBasic Repairs Brush Replacement Brushholder ReplacementSEMI±ANNUALLY Installation Brushholder Clearance AdjustmentCommutator Resurfacing Sanding Procedure Hand Stoning ProcedureGrinder Installation Fixture GrindingCommutator GRINDER. E±18249 Grinding ±19771ATesting Before Disassembly Air Curing CommutatorBasic Overhaul Disassembly Megohmmeter TestBar±To±Bar Resistance Test Armature Removal From FrameCOMMUTATOR±END Bearing Pilot Longitudinal D732922 CHG. N. E±28621D Models See , Description Puller Tools 41D731569 CHG . E±14383C Puller TOOLS. E±18155A Models US1, AUT Longitudinal D735357, CHG. A. E±37949B Models See Table Cleaning Steam CleaningVapor Degreasing Anti±Friction Bearings/Shaft Tapers/Bearing FitsBearing Inspection ArmatureCommutator Armature Shaft InspectionMotor Frame Armature Insulation 41D731545 CHG. F. E±18156A See Note Brushholders Lubrication of BoltsConnection Diagram 493A210 CHG . E±39092B Creepage Band Replacement Rewinding ArmatureRiser Width DiameterProcedure Commutator TighteningHydraulic Press Preferred Method Torque Wrench Acceptable MethodSpin Seasoning Commutator Assembled On Armature Commutator ResurfacingTurning To Change Motor DirectionConnection Diagram 41A330278, CHG . E±38055B Connection Diagram 41A330179, CHG. A. E±37950A Raking ±4270BResistance Measurement Test After Repair Armature High Potential TestUsed Armature Rewound ArmatureReplacement Coil InstallationProcedure for New Coil±Pole Assembly Motor Frame Field CoilCoiled Frame Assembly 41D732353 CHG. N. E±39094A Models See , Coiled Frame Assembly 41D732345 CHG. V. E±39095A BOX Ground A1 and A2 View AT E Cables with P65 Coiled Frame Assembly 41D735440, CHG. A. E±38056B Description Magnet Frame Coiled Frame Assembly 41D735343, CHG. C. E±37951C Hardened Washer 1 1/4 Brazing Coil Terminals Gas Torch BrazingFlood Dipping Coiled Frame Test After RepairCoiled Frame Without Armature Reassembly Balancing ArmatureVarnish Treatment Armature Armature Bearings Drive±End Bearing Figs , 35, 36Commutator±End Bearing All Models Except US2, UP6, AUT2 and AUP5DRIVE±END Bearing ASSEMBLY. E±18166E DRIVE±END Bearing ASSEMBLY. E±39301 Models US2, UP6, AUT2 and AUP5DRIVE±END Bearing Assembly 41B537821, CHG. B. E±37952B Armature Assembly Into Frame Models UP and AUPCOMMUTATOR±END Bearing Assembly 41B532745 CHG. F. E±39090A COMMUTATOR-END Bearing Assembly 41B538068 CHG . E-39300 Checking Internal Clearance Brush Installation HUB Mounting Hub FittingHub Mounting Testing After Overhaul Testing Series MachinesModels 5GE752AUP, AUT Testing Shunt Machines Models 5GE752UP and US Motor OperationVentilated 2300 cfm at 7.6 in. H2O at Commutator Chamber UnventilatedCleaning and Slushing Removing Armature Locking ArrangementLocking the Armature For Shipment ShippingSkidding ProtectionArmatures Preparation of BOXBoxing the Armature Storage Placing Into StorageRemoving from Storage Shipping BOX with Armature Less COVER. E±3784Vertical Drilling Motor, Type GE752, GEK±91584D OUTLINE, UP and AUP 41E903631 CHG. H. E±28755B Hole Grease Vent Tube Grease Tube Holes REF OUTLINE, US1, AUT 41E903745, CHG. A. E±37954B ºDº ºBº Vertical Drilling Motor, Type GE752, GEK±91584D GE Transportation Systems