GE GE752 manual Removing Armature Locking Arrangement, Locking the Armature For Shipment, Shipping

Page 69

Vertical Drilling Motor, Type GE752, GEK±91584D

WARNING: Electric shock can cause serious or fatal injury. To avoid such injury, personnel should take and observe proper precautions during the high±potential testing.

REMOVING ARMATURE

LOCKING ARRANGEMENT

(See Fig. 43)

1.Remove the two shipping bolts (1) from the bear- ing cap. These bolts are longer and can be identi- fied from the factory by their yellow heads.

2.Install the two regular bolts which are in a bag at- tached to one of the shipping bolts.

3.Torque the regular bolts to 115 lb.±ft.

NOTE: The shipping bolts and bag should be saved for future armature locking require- ments.

LOCKING THE ARMATURE

FOR SHIPMENT

(See Fig. 43)

1.Remove two diametrically opposite bolts in the commutator end bearing cap.

2.Install shipping bolts (1) (painted yellow) with jam nuts (2) applied. Torque bolts to 30 lb.±ft. and tighten the jam nuts.

CAUTION: Do not rotate the armature when the locking bolts are in place. Bearing and commutator damage may result.

3.Attach the two regular bolts and bag±tag (5) to one of the locking bolts (1).

SHIPPING

Whenever drilling motors are to be shipped, they must be properly skidded and secured to prevent any damage in transit. The photographs and drawings which follow illustrate a proven method of skidding these ma- chines for handing and shipment.

FIG. 43. ARMATURE LOCKING ARRANGEMENT

(41B535748 CHG. 0). E±28735A.

HANDLING

To avoid damage to the machine during handling, re- view the following cautionary statements:

1.Do not lift motors by the shaft extension of the ar- mature.

2.Do not allow the armature to bump another ob- ject.

3.Do not tighten coupling assembly bolts with an air wrench or by pounding.

4.Do not remove armature end±play by any other means than axial blocking.

5.Do not load the armature radially (strap down) for shipment.

CLEANING AND SLUSHING

Before skidding the machine for shipment, all ex- posed finished surfaces not already painted should be cleaned and slushed as follows:

69

Image 69
Contents Vertical Drilling Motor Type GE752 ContentsGeneral Description IntroductionGEK±91584D, Vertical Drilling Motor, Type GE752 Model Differences Vertical Drilling Motor, Type GE752, GEK±91584DData Contd Model DifferencesCarbon Brushes Data ContdPole Bore Diameter measured at center of pole Motors Min Max Motor Ratings Continuous Max. HP Shunt UP Grounding Instructions Special Tools EquipmentOverhaul Grounding Procedures FigLubrication Grease Tubes and Pipe PlugsInspection Monthly Covers, Seals, LatchesBrushholders Fig Brush Spring Pressure Brushholder SleevesCommutator BrushesCreepage Band Flash RingBasic Repairs Brush Replacement Brushholder ReplacementSEMI±ANNUALLY Installation Brushholder Clearance AdjustmentCommutator Resurfacing Hand Stoning Procedure Sanding ProcedureFixture Grinding Grinder InstallationCommutator GRINDER. E±18249 ±19771A GrindingTesting Before Disassembly Air Curing CommutatorBasic Overhaul Megohmmeter Test DisassemblyBar±To±Bar Resistance Test Armature Removal From FrameCOMMUTATOR±END Bearing Pilot Longitudinal D732922 CHG. N. E±28621D Models See , Description Puller Tools 41D731569 CHG . E±14383C Puller TOOLS. E±18155A Models US1, AUT Longitudinal D735357, CHG. A. E±37949B Models See Table Steam Cleaning CleaningAnti±Friction Bearings/Shaft Tapers/Bearing Fits Vapor DegreasingBearing Inspection ArmatureCommutator Armature Shaft InspectionMotor Frame Armature Insulation 41D731545 CHG. F. E±18156A See Note Lubrication of Bolts BrushholdersConnection Diagram 493A210 CHG . E±39092B Rewinding Armature Creepage Band ReplacementRiser Width DiameterCommutator Tightening ProcedureHydraulic Press Preferred Method Torque Wrench Acceptable MethodCommutator Resurfacing Spin Seasoning Commutator Assembled On ArmatureTo Change Motor Direction TurningConnection Diagram 41A330278, CHG . E±38055B Connection Diagram 41A330179, CHG. A. E±37950A ±4270B RakingTest After Repair Armature High Potential Test Resistance MeasurementUsed Armature Rewound ArmatureCoil Installation ReplacementProcedure for New Coil±Pole Assembly Motor Frame Field CoilCoiled Frame Assembly 41D732353 CHG. N. E±39094A Models See , Coiled Frame Assembly 41D732345 CHG. V. E±39095A BOX Ground A1 and A2 View AT E Cables with P65 Coiled Frame Assembly 41D735440, CHG. A. E±38056B Description Magnet Frame Coiled Frame Assembly 41D735343, CHG. C. E±37951C Hardened Washer 1 1/4 Gas Torch Brazing Brazing Coil TerminalsFlood Dipping Coiled Frame Test After RepairCoiled Frame Without Armature Reassembly Balancing ArmatureVarnish Treatment Armature Drive±End Bearing Figs , 35, 36 Armature BearingsCommutator±End Bearing All Models Except US2, UP6, AUT2 and AUP5DRIVE±END Bearing ASSEMBLY. E±18166E Models US2, UP6, AUT2 and AUP5 DRIVE±END Bearing ASSEMBLY. E±39301DRIVE±END Bearing Assembly 41B537821, CHG. B. E±37952B Models UP and AUP Armature Assembly Into FrameCOMMUTATOR±END Bearing Assembly 41B532745 CHG. F. E±39090A COMMUTATOR-END Bearing Assembly 41B538068 CHG . E-39300 Checking Internal Clearance Brush Installation HUB Mounting Hub FittingHub Mounting Testing After Overhaul Testing Series MachinesModels 5GE752AUP, AUT Motor Operation Testing Shunt Machines Models 5GE752UP and USVentilated 2300 cfm at 7.6 in. H2O at Commutator Chamber UnventilatedRemoving Armature Locking Arrangement Cleaning and SlushingLocking the Armature For Shipment ShippingProtection SkiddingArmatures Preparation of BOXStorage Placing Into Storage Boxing the ArmatureShipping BOX with Armature Less COVER. E±3784 Removing from StorageVertical Drilling Motor, Type GE752, GEK±91584D OUTLINE, UP and AUP 41E903631 CHG. H. E±28755B Hole Grease Vent Tube Grease Tube Holes REF OUTLINE, US1, AUT 41E903745, CHG. A. E±37954B ºDº ºBº Vertical Drilling Motor, Type GE752, GEK±91584D GE Transportation Systems