Bosch Power Tools DUH Installing the Hood, Parts Included with your Hood, Tools required

Page 5

Parts Included with your Hood

Hood Canopy Assembly with Round Metal Transition installed.

Rectangular Metal Transition with Back draft dampers.

Care & Use /Installation Instructions

2 Filters

Fitting Screws.

Parts Not Included with your Hood

Duct Tape

1/2" Conduit

Wire Nuts

Round or Rectangular Duct.

Charcoal filters

Round back draft damper

Wiring clamp

Models DUH30252UC and DUH36252UCOnly:

CAUTION! Lamps are not supplied, use ONLY 120 Volt, 50 Watt (maximum) 50° halogen light made or a GU10 base.

Tools required

Flat blade and Phillips screwdrivers Pencil

Metal snips (in some applications) Electric drill

Saw (saber or keyhole) Duct tape

Pliers

Level Caulking Tape measure 1/4.pivoting hex socket Flashlight

Wire stripper 1/4. Nutdriver Small hammer

INSTALLING THE HOOD

For the most efficient air flow exhaust, use a straight run or as few elbows as possible.

CAUTION: Vent unit to outside of building, only.

One person is necessary for installation.

On avarage 2 hours are necessary to complete installation (without considering cut to be done on wall and or on cabinet, installation of ducts , conduit and electrical connections to the mains).

16 installation steps are required.

The hood is fitted with Screws and Drywall Anchors suitable for most surfaces, consult a Qualified Installer, check if they perfectly fit with your cabinet/wall.

Do not use flex ducting.

COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize

conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the ducting enters the heated portion of the house.

Remote blowers require a five wire installation.

Make up air: Local building codes may require the use of Make-Up Air Systems when using Ducted Ventilation Systems greater than specified CFM of air movement.

The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.

Typical installation

Min installation height from the countertop to the bottom of the hood is 24” to 30“.These hoods are not recommended to be used over indoor grills.

5

Image 5
Contents Bosch ventilation installation manual DUH Models Page Operation Read All Instructions Before Using the ApplianceTo Reduce the Risk of FIRE, USE only Metal Duct Work Electrical requirements Parts Included with your Hood Installing the HoodParts Not Included with your Hood Tools requiredVertical discharge Choose vent options Vent Exhaust OptionHorizontal discharge Recirculating Vertical discharge Horizontal dischargeTotal of both columns= After having choosen the vent option, proceed as follows Ductwork Installation GuidelinesPivot Top/back edge Exhaust transition/damper Outside top exhaust Mark holesOutside rear exhaust RecirculatingFailure to do so can result in death or electrical shock Choose Venting Option120 VAC, 15 or 20 Amp circuit required Page Modeopératoire AvertissementAvertissement Spécifications électriques Lire Toutes les Instructions Avant d’Utiliser l’AppareilÉléments compris avec votre hotte Installation DE LA HotteÉléments non compris avec votre hotte Outils nécessairesRecyclage d’air Évacuation verticale Évacuation horizontale Évacuation verticaleÉvacuation horizontale 10 po Étape Après avoir choisi le type d’évacuation, procéderPivot Top/backArrière de la hotte edge Évacuation extérieure par le dessus de la hotte Étape Emplacement des trousÉvacuation extérieure par l’arrière de la hotte Recyclage d’airInstructions Pour LE Raccordement À LA Terre Étape Étape finale d’installationRaccorderlahotteaucircuitélectrique Leer LAS Instrucciones Antes DEL USO Funcionamiento AdvertenciaAdvertencia Requisitos eléctricos Leer Todas las Instrucciones Antes de Usar el AparatoPartes Incluidas con la Campana Herramientas necesarias Instalar LA CampanaPartes no incluidas con la campana Se requieren 16 pasos para la instalaciónDescarga vertical Escoger las opciones de descarga de los gases de combustiónDescarga horizontal Recirculación Descarga Vertical Descarga HorizontalTotal de ambas columnas= ¡ Atención Re-instalar la transición redonda con sus tornillos Extractor posterior exterior Marcar los orificiosExtractor superior exterior 10.Sólo para gabinetes ahuecados Escoger la Opción de DescargaAdvertenciascableadocampana Instrucciones DE Conexión EléctricaLI2WVB