9.Choose Venting Option
The hood can be set to vent outside or to recirculate air back into the kitchen.
The plastic vent lever is located near the center of the hood opening.
To vent to the outside, make sure the plastic vent lever is in the HORIZONTAL position (flat against the metal top of the hood).
To recirculate air into the kitchen, make sure the plastic vent lever is in the VERTICAL position (flat against the plastic blower housing). NOTE: In order to change the vent lever position, you will need to pull the lever out slightly to clear the plastic tabs.
10.For recessed bottom cabinet only
If the cabinets have front, side or back trim, make 2 wood shims the width of the trim and attach them to the cabinet bottom recess on both sides. See previous page for marking locations.
11.Cut holes at marked locations for duct and electrical wiring. For the vertical duct, cut out 3/ 4” extra toward the front of the cabinet so you can move the duct freely when installing the hood.
It may also ease installation by cutting the hole 10 1/2” instead of 10”.
12.Drive a mounting screw (from the hardware packet) partway into each center of the narrow neck of the keyhole slots marked on the cabinet bottom.
13.Fix the wiring conduit to the hood.
14.Slide the hood back against the wall. Tighten the mounting screws. Be sure the screw heads are in the narrow neck of the keyhole slot. Connect Ductwork to hood.
15.WIRING THE HOOD
WARNING Electrical Shock Hazard
Warning: Turn off power at the service panel before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE MUST BE CONNECTED TO THE GROUNDING WIRE IN YOUR
HOME ELECTRICAL SYSTEM, AND IT MUST UNDER NO CIRCUMSTANCES BE CUT OR REMOVED.
Set for | Set for |
outside venting | recirculating |
Stop tab |
|
| Stop tab |
Hood shown Lying upside down
Wood shims
Failure to do so can result in death or electrical shock.
•If not already done, install 1/2” conduit connector in
•Run black (live), white (neutral), and green (earth) wires (#14 AWG) according to the National Electrical Code or CSA Standards and local codes and ordinances in 1/2” conduit from power supply to
•Connect black, white, and green wires from power supply to black (live), white (neutral), and green/yellow (earth) wires in
•These connections should be done always making reference to the electrical diagram found inside the hood.
•Close
Final installation steps
16.Replace filters as described in the Care & Use section of this manual.
Models DUH30252UC and DUH36252UCOnly: Install the lamps on proper housings.
Note: Lamps are not supplied, use ONLY 120 Volt, 50 Watt (maximum) 50° halogen light made for a GU10 base, suitable for use in open luminarie.
Turn power on at service panel. Check operation of the hood.
11