motor specifications and emedrkaR requkernents :
This machine is designed to use a 3450 RPM motor only. Do not use any motor that runs faster than 3450 RPM.
It is wired for operation on
nating current. IT MUST NOT BE CONVERTED TO
OPERATE ON 230 VOI.TS, EVEN THOUGH SOME OF
THE RECOMMENDED MOTORS ARE DUAL VOLTAGE.
THESE CRAFTSMAN MOTORS HAVE BEEN
FOUND TO BE ACCEPTABLE FOR USE ON THIS TOOL.
H P | RP_a | VOLTS | CATALOG | NO. |
1/2 | 3450 | 110q20 | 1216 |
|
1/2 | 3450 | 1218 |
| |
3/4 | 3450 | 12t9 |
| |
3/4 | 3450 | 1226 |
|
CAUTION: Do not use blower or washing machine motors or any motor with an automatic reset overload protector
as their use may be hazardous.
CONNECTING TO POWER SOURCE OUTLET
This machine must be grounded while in use to protect the operator from etectric shock.
Plug power cord into a 110_120V properly grounded type
outlet protected by a
If you are not sure that your outlet is properly grounded, have it checked by a qualified electrician.
WARNING: DO NOT PERMIT FINGERS TO TOUCH
THE TERMINALS OF PLUGS WHEN INSTALLING OR
REMOVING THE PLUG TO OR FROM THE OUTLET.
WARNING: IF NOT PROPERLY GROUNDED THIS
POWER TOOL CAN INCUR THE POTENTIAL HAZARD
OF ELECTRICAL SHOCK. PARTICULARLY WHEN USED
IN DAMP LOCATIONS IN PROXIMITY TO PLUMBING.
IF AN ELECTRICAL SHOCK OCCURS THERE IS THE
POTENTIAL OF A SECONDARY HAZARD SUCH AS
YOUR HANDS CONTACTING THE CUTTING BLADE,
If power cord is worn or cut, or damaged in any way, have it replaced immediately.
PROPERLY
GROUNDED
OUTLET_._
GROUNDING
PRONG
This power too! is equipped with a
Underwriters" Laboratories Association, The ground
conductor has a green jacket and is attached to the tool
housing at one end and to the ground prong in the
attachment plug at the other end.
This piug requires a mating
If the outlet you are planning to use for this power too_ is
of the two prong type DO NOT REMOVE OR ALTER
THE GROUNDING PRONG IN ANY MANNER. Use an
adapter as shown and always connect the grounding lug to known ground,
It is recommended that you _nave a quafified electrician replace the TWO prong outlet with a properhi grounded THREE prong outlet,
An adapter as shown below is available for connecting plugs to
MAKE | SURE | THIS |
| IS | GROUNDING | LUG | |
A |
|
| |||||
CONNECTED | TO |
| i |
|
| ||
KNOWN | GROUND |
|
|
|
| ADAPTER | |
|
|
|
|
|
|
| |
|
|
|
|
| H |
| |
|
|
|
|
| i |
| |
|
|
|
|
| Li |
| PLUG |
| J |
| |
RECEPTACLE |
|
NOTE: The adapter illustrated is for use onIy if you already
have a properly grounded
The use of any extension cord will cause some loss of
power. To keep this to a minimum and to prevent over- heating and motor
only 3 wire extension cords which have
Extension | Cord | Length | Wire Size A.W.G. |
Up to | 100 | Ft. | 14 |
100 | - 200 | Ft. | 12 |
200- | 400 | Ft. | 8 |
CHECK MOTOR ROTATION
WARNING: FOR YOUR OWN SAFETY, MAKE SURE PLUG IS NOT CONNECTED TO POWER SOURCE OUT* LET WHEN CHANGING MOTOR ROTATION.
The motor must rotate COUNTERCLOCKWISE when viewed from the shaft end to which you wilI mount the pulley, (See page 10}, If it does not, change the direction
according to the instructions furnished with the motor,