Extension cords
The use of an extension cord is not recommended for the PJ882 Jointer. But if one is necessary, make sure the cord rating is suitable for the amperage listed on the machine’s motor plate. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating.
Use the chart in Figure 8 as a general guide in choosing the correct size cord. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
230 Volt, Single Phase Operation
As received from the factory, the
The jointer has a grounding plug that looks like the plug illustrated in Figure 9; or you may choose to
If the Jointer is to be
The Jointer with a 230 volt plug should only be connected to an outlet having the same configuration. No adapter is available or should be used with the 230 volt plug.
It is recommended that the single phase jointer be connected to a dedicated, minimum 20 amp circuit with a 20 amp circuit breaker or time delay fuse. Local codes take precedence over recommendations.
Three Phase Operation
The
If you are
Recommended Gauges (AWG) of Extension Cords
|
|
| Extension Cord Length * |
| |||
|
|
|
|
|
|
|
|
Amps | 25 | 50 | 75 | 100 | 150 | 200 | |
feet | feet | feet | feet | feet | feet | ||
|
|
|
|
|
|
|
|
< 5 |
| 16 | 16 | 16 | 14 | 12 | 12 |
|
|
|
|
|
|
|
|
5 to | 8 | 16 | 16 | 14 | 12 | 10 | NR |
|
|
|
|
|
|
| |
8 to 12 | 14 | 14 | 12 | 10 | NR | NR | |
|
|
|
|
|
|
|
|
12 to | 15 | 12 | 12 | 10 | 10 | NR | NR |
|
|
|
|
|
|
|
|
15 to | 20 | 10 | 10 | 10 | NR | NR | NR |
|
|
|
|
|
|
|
|
21 to | 30 | 10 | NR | NR | NR | NR | NR |
|
|
|
|
|
|
|
|
*based on limiting the line voltage drop to 5V at 150% of the rated amperes.
NR: Not Recommended.
Figure 8
Figure 9
It is recommended that the three phase jointer, when operated at 230 volts, be connected to a dedicated, minimum 20 amp circuit with a 20 amp circuit breaker or time delay fuse. When operated at 460 volts, connect the jointer to a dedicated, minimum 15 amp circuit with 15 amp circuit breaker or time delay fuse. Local codes take precedence over recommendations.
Converting from 230 Volt to 460 Volt (Three Phase Only)
Consult the wiring diagram inside the starter box cover. A diagram is also included on page 46 of this manual. The Jointer must comply with all local and national codes after being wired.
1.Replace the current contactor with the 460V magnetic contactor (part no.
2.
3.If using a plug, install a proper UL/CSA listed plug suitable for 460 volt operation.
12