Miller Electric SS-75S12 manual Installing Welding Gun, Installing gun with Accu-Mate connection

Page 21

4-14. Installing Welding Gun

1 2

Installing gun with

Accu-Mate connection

804 730-A

3

4

1 2

Installing gun without

Accu-Mate connection

1Gun Locking Tab

2Power Clamp Knob

3Power Pin Groove

4Gun Connection End

Installing gun with Accu-Mate connec- tion

Loosen power clamp knob to allow power pin of gun to clear the gun locking tab.

When installing gun, the liner should extend

into the PD continuous guide (or exit guide if used) as far as possible without interfer- ing with the guide.

Align the groove in the power pin of the gun with the gun locking tab.

Secure gun by tightening power clamp knob.

Installing gun without Accu-Mate con- nection

When using a gun without the groove in the power pin, loosen power clamp knob and rotate gun locking tab 180 degrees. This prevents the locking tab from extending into the power pin gun connection.

When installing gun, the liner should extend into the PD continuous guide (or exit guide if used) as far as possible without interfer- ing with the guide.

Secure gun by tightening power clamp knob.

OM-230 298 Page 17

Image 21
Contents Processes OM-230 298ADescription File MIG GmawFrom Miller to You Table of Contents Page Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings Principal Safety Standards EMF InformationAbout Pacemakers UNE Décharge Électrique peut entraîner la mort LES Fumées ET LES GAZ peuvent être dangereuxIndique un message de sécurité particulier Incendie ou une explosion LE Soudage peut provoquer unDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU D’EXPLO’EMPLOI Excessif peut SUR DES Organes Mobiles peuvent provoquer des blessuresEn ce qui concerne les stimulateurs cardiaques Principales normes de sécuritéSpecifications − InstallationInstalling Swivel Into Pipe Post − IntroductionInstalling Boom And Reel Support Adjusting Control Tilt BracketEquipment Connection Diagram Installing Wire Guide ExtensionControl Box Connections Pin Plug InformationPin Information Wire Type, Size, And Feed Speed Capability Table Removing Safety Collar And Adjusting BoomMotor Speed Wire Type Wire Size Feed Speed Capability Gun Recommendation Table Installing Drive Rolls Installation Removal Installing PD continuous wire guides with PD drive rolls Installing PD Continuous Wire GuidesInstalling wire guides with non- PD old- style drive rolls Installing Non-PD Old Style Wire GuidesInstalling gun with Accu-Mate connection Installing Welding GunInstalling gun without Accu-Mate connection Installing gun with Accu-Mate connec- tionInstalling Welding Wire And Adjusting Pressure Drive Setting Run-In Disabled S1-1 Setting Internal DIP SwitchesManually Adjusted Run-In S1-1 And S1-2 S1-1 And S1-2Digital Meter DIP Switch Setting Equipment DIP Switch Settings For Models With Meters OnlyGeneral Terms Cold Wire Jog − OperationJog/Purge And Trigger Hold Power SwitchYou can adjust the preset volt Routine Maintenance − Maintenance and TroubleshootingBrush Inspection And Replacement Disconnect power before maintainingDiagnostics Indicated ErrorError Indications Troubleshooting Disconnect power before troubleshootingTrouble Remedy Circuit Diagram − Electrical DiagramStart Your Professional Welding Career Now Main Assembly − Parts ListQuantity Control Box 070 Boom Assembly Boom Assembly -1Item Drive Assembly, Wire Drive Assembly With Motor Support, Hub & Reel PD-V OM-230 298 Support ServiceMiller Electric Mfg. Co Owner’s Record