4-16. Setting Internal DIP Switches

Remove wrapper.

1 DIP Switch S1 On Motor Board PC1

S1-1

Run-In enable or disable.

S1-2

Automatic Run-In versus Manual Adjustment Run-in

Install wrapper when finished.

P1

Factory Set Default Set-

 

tings For DIP Switch S1

1

. In the DIP switch S1 illustrations, the elevated slider on each switch is shown in white. For example, the switches above are in the Off position.

Tools Needed:

1/4 in

Position Settings And Results For DIP Switch S1 On PC1

Run-In Enabled

(Factory Default)

S1-1

Run-In feature is available.

X - Means switch may be in either position.

.If 14 pin power cable from pow-

er source does not provide volt- age and current feedback, Run- In will automatically disable.

Run-In Disabled

S1-1

Run-In feature is not avail- able. X - Means switch may be in either position.

Automatic Run-In (Factory Default)

S1-1 And S1-2

Run-In speed is approxi- mately 1/2 weld wire feed speed.

Manually Adjusted Run-In

S1-1 And S1-2

Run-In speed is set using poten- tiometer P1 located on Motor Board PC1.

.P1 is a 25 turn potentiometer.

803 063 / Ref. 802 944

OM-230 298 Page 19

Image 23
Contents File MIG Gmaw OM-230 298AProcesses DescriptionFrom Miller to You Table of Contents Page Electric Shock can kill Symbol UsageMarks a special safety message Arc Welding HazardsBuildup of GAS can injure or kill ARC Rays can burn eyes and skinWelding can cause fire or explosion Flying Metal can injure eyesCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information Indique un message de sécurité particulier UNE Décharge Électrique peut entraîner la mortLES Fumées ET LES GAZ peuvent être dangereux DES Pièces Chaudes peuvent provoquer des brûlures graves LE Soudage peut provoquer unIncendie ou une explosion DES Particules Volantes peuvent blesser les yeuxDES Organes Mobiles peuvent provoquer des blessures Risque D’INCENDIE OU D’EXPLOLA Chute DE L’APPAREIL peut blesser ’EMPLOI Excessif peut SUREn ce qui concerne les stimulateurs cardiaques Principales normes de sécurité− Introduction − InstallationSpecifications Installing Swivel Into Pipe PostInstalling Boom And Reel Support Adjusting Control Tilt BracketEquipment Connection Diagram Installing Wire Guide ExtensionPin Information Control Box ConnectionsPin Plug Information Gun Recommendation Table Removing Safety Collar And Adjusting BoomWire Type, Size, And Feed Speed Capability Table Motor Speed Wire Type Wire Size Feed Speed CapabilityRemoval Installing Drive RollsInstallation Installing PD continuous wire guides with PD drive rolls Installing PD Continuous Wire Guides Installing wire guides with non- PD old- style drive rolls Installing Non-PD Old Style Wire GuidesInstalling gun with Accu-Mate connec- tion Installing Welding GunInstalling gun with Accu-Mate connection Installing gun without Accu-Mate connectionInstalling Welding Wire And Adjusting Pressure Drive Setting S1-1 And S1-2 Setting Internal DIP SwitchesRun-In Disabled S1-1 Manually Adjusted Run-In S1-1 And S1-2− Operation Equipment DIP Switch Settings For Models With Meters OnlyDigital Meter DIP Switch Setting General Terms Cold Wire JogJog/Purge And Trigger Hold Power SwitchYou can adjust the preset volt Disconnect power before maintaining − Maintenance and TroubleshootingRoutine Maintenance Brush Inspection And ReplacementError Indications DiagnosticsIndicated Error Trouble Remedy TroubleshootingDisconnect power before troubleshooting Circuit Diagram − Electrical DiagramStart Your Professional Welding Career Now Main Assembly − Parts ListQuantity Control Box 070 Boom Assembly Boom Assembly -1Item Drive Assembly, Wire Drive Assembly With Motor Support, Hub & Reel PD-V OM-230 298 Support ServiceMiller Electric Mfg. Co Owner’s Record