Miller Electric PipePro 304 manual HOT Parts can cause burns and injury, Fire or Explosion hazard

Page 8

HOT METAL from air arc cutting and gouging can cause fire or explosion.

DDo not cut or gouge near flammables.

DWatch for fire; keep extinguisher nearby.

HOT PARTS can cause burns and injury.

DDo not touch hot compressor or air system parts.

DLet system cool down before touching or ser- vicing.

READ INSTRUCTIONS.

DRead Owner’s Manual before using or servic- ing unit.

DStop engine and release air pressure before servicing.

DUse only genuine replacement parts from the manufacturer.

1-5. Additional Symbols For Installation, Operation, And Maintenance

FIRE OR EXPLOSION hazard.

D Do not install or place unit on, over, or near combustible surfaces.

DDo not install unit near flammables.

DDo not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.

WELDING WIRE can cause injury.

DDo not press gun trigger until instructed to do so.

DDo not point gun toward any part of the body, other people, or any metal when threading welding wire.

FALLING UNIT can cause injury.

DUse lifting eye to lift unit and properly installed accessories only, NOT gas cylinders. Do not exceed maximum lift eye weight rating (see Specifications).

DLift and support unit only with proper equipment and correct procedures.

DIf using lift forks to move unit, be sure forks are long enough to extend beyond opposite side of unit.

OVERHEATING can damage motors.

DTurn off or unplug equipment before starting or stopping engine.

DDo not let low voltage and frequency caused by low engine speed damage electric motors.

DDo not connect 50 or 60 Hertz motors to the 100 Hertz receptacle where applicable.

FLYING SPARKS can cause injury.

D Wear a face shield to protect eyes and face.

D Shape tungsten electrode only on grinder with proper guards in a safe location wearing proper face, hand, and body protection.

DSparks can cause fires — keep flammables away.

MOVING PARTS can cause injury.

DKeep away from moving parts.

DKeep away from pinch points such as drive rolls.

OVERUSE can cause OVERHEATING.

DAllow cooling period; follow rated duty cycle.

DReduce current or reduce duty cycle before starting to weld again.

DDo not block or filter airflow to unit.

STATIC (ESD) can damage PC boards.

DPut on grounded wrist strap BEFORE handling boards or parts.

DUse proper static-proof bags and boxes to store, move, or ship PC boards.

TILTING OF TRAILER can cause injury.

DUse tongue jack or blocks to support weight.

DProperly install welding generator onto trailer according to instructions supplied with trailer.

READ INSTRUCTIONS.

DRead Owner’s Manual before using or servic- ing unit.

DUse only genuine replacement parts from the manufacturer.

DPerform engine and air compressor mainte- nance and service according to this manual and the engine/air compressor (if applicable) manuals.

OM-492 Page 4

Image 8
Contents Processes DescriptionFile Engine-Driven Visit our website at OM-492190 603BF 2007−05From Miller to You Table of Contents Options and Accessories Warranty Symbol Usage Arc Welding HazardsElectric Shock can kill HOT Parts can cause severe burnsFumes and Gases can be hazardous Buildup of GAS can injure or killARC Rays can burn eyes and skin Welding can cause fire or explosionEngine Hazards Compressed Air HazardsWelding Wire can cause injury HOT Parts can cause burns and injuryFire or Explosion hazard Falling Unit can cause injuryPrincipal Safety Standards California Proposition 65 WarningsEMF Information Radiation can cause interferenceSignification des symboles − Consignes DE Sécurité − Lire Avant UtilisationUN Choc Électrique peut tuer Indique des instructions spécifiquesDES Pièces Chaudes peuvent provoquer des brûlures graves LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut provoquer un in cendie ou une explosion LE Bruit peut affecter l’ouïe’EXPLOSION DE LA Batterie peu DES Organes Mobiles peuvent pro voquer des blessuresRisque D’INCENDIE OU D’EXPLO- Sion LA Chaleur DU Moteur peut pro- voquer un incendie’AIR Comprimé peut provoquer des blessures LE Surchauffement peut endom- mager le moteur électrique DES Organes Mobiles peuvent provoquer des blessuresLES Fils DE Soudage peuvent provoquer des blessures ’EMPLOI Excessif peutProposition californienne 65 Avertissements Principales normes de sécuritéInformation EMF En ce qui concerne les implants médicaux− Specifications Symbol DefinitionsWeld, Power, And Engine Specifications − DefinitionsDimensions, Weights, and Operating Angles Duty Cycle And OverheatingVolt-Ampere Curves CC ModeCV Mode Fuel Consumption − Installation Installing Welding GeneratorEngine Prestart Checks This unit has a low oil pressure shutFuel OilConnecting The Battery ConnectNegative − Cable lastInstalling Exhaust Pipe Tools Needed 1/2Connecting To Weld Output Terminals Correct InstallationStop engine Stick And TIG WeldingSelecting Weld Cable Sizes Remote 14 Receptacle RC14 InformationStop engine, and let cool Use thick-walled rubber hose. Do not useEngine Mount on lower Front panelOperating Engine Block Heater − Operating Welding Generator Controls See SectionDescription Of Controls See Section Mode Switch Settings Mode Meter Reading At Idle Meter Reading While WeldingMode Switch Setting Process Output On/Off Control Meter FunctionsLift-Arc TIG Procedure BatteryRecommendations For Extreme Cold Weather Operation Starting Do not use etherGenerator Power Receptacles And Circuit Breakers Generator power decreases as weld current increases− Operating Auxiliary Equipment Weld Total 120Optional Gfci Receptacles And Circuit Breakers If unit does not have GfciReceptacles, use GFCI-pro Tected extension cordCurrent Available in Amperes 240 Receptacle− Maintenance and Troubleshooting Maintenance LabelRoutine Maintenance Servicing Spark Arrestor Stop engine and let coolServicing Air Cleaner To clean air filterServicing Engine Lubrication And Fuel Systems Servicing Engine Cooling System Adjust throttle link Throttle arm Replacing Throttle Solenoid TS1− cable first Be sure solenoid plunger rodAdjusting Engine Speed Adjusting Idle SpeedAdjusting Weld/Power Speed Using Engine Stop LeverOverload Protection Voltmeter/Ammeter Help Displays Trouble Remedy TroubleshootingWelding Necessary parts Generator PowerNo power output Reset supplementary protectors see Section Engine CT1 Work like a Pro − Electrical Diagrams Circuit Diagram For Welding Generator212 633-F − RUN-IN Procedure Procedure at less thanWetstacking Do not perform run-inRun-In Procedure Using Load Bank Run-In Procedure Using Resistance Grid From flammablesGrounding Generator To Truck Or Trailer Frame − Generator Power GuidelinesSelecting Equipment Grounding When Supplying Building Systems How Much Power Does Equipment Require?Use ground device as stated in electrical codes Amperes x Volts = WattsApproximate Power Requirements For Industrial Motors Approximate Power Requirements For Farm/Home EquipmentIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsPower Required To Start Motor How Much Power Can Generator Supply?Single-Phase Induction Motor Starting Requirements KVA/HP x HP x 1000 / Volts = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible − Parts List 105 104 10230 Fig Item Dia Part Description Quantity Mkgs Dia Part Description Quantity Mkgs 213 Front Panel 24 PL1, PL2, PL3 Inverter Assembly Inverter Assembly -1, Item24 . . HD1 189 Generator Work like a Pro TM-188 304 Invision 354MP Start Your Professional Welding Career Now Support ServiceYour distributor also gives To locate a Distributor or Service Agency visit Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s