MMD 540H Hybrid Multimeter Meter Functions 21
Meter Functions – Dwell ()
ÑSelect the “DWELL” function with the rotary switch.
Insert:
ÑBlack lead in COM terminal.
ÑRed lead in
Connect the Black test probe to ground.
Connect the Red test probe to the wire that connects to the breaker points (see illustration).
Black–Red+
To breaker
Points
MMD 540H Instruction Manual Version 1 February 2008 | Robert Bosch LLC |