Logical Port to GEA Port mapping
Command: /info/geaport
Logical Port | GEA | GEA Unit |
1 | 1 | 0 |
2 | 2 | 0 |
3 | 4 | 0 |
4 | 7 | 0 |
5 | 8 | 0 |
6 | 12 | 0 |
7 | 13 | 0 |
8 | 14 | 0 |
9 | 0 | 0 |
10 | 3 | 0 |
11 | 5 | 0 |
12 | 6 | 0 |
13 | 9 | 0 |
14 | 10 | 0 |
15 | 11 | 0 |
16 | 15 | 0 |
17 | 16 | 0 |
18 | 17 | 0 |
19 | 18 | 0 |
20 | 19 | 0 |
21 | 23 | 0 |
22 | 22 | 0 |
23 | 21 | 0 |
24 | 20 | 0 |
This display correlates the logical port number to the GEA unit on which each port resides.
Uplink Failure Detection information
Command: /info/ufd
Uplink Failure | Detection: Enabled |
| ||
LtM status: Down |
| |||
Member |
| STG | STG State | Link Status |
port 24 | 1 | DISABLED | down | |
|
|
| ||
|
| 10 | DISABLED * |
|
|
| 15 | DISABLED * |
|
* = STP turned | off for this port. |
| ||
LtD status: Auto Disabled |
| |||
Member |
| Link Status |
| |
| ||||
port | 1 |
| disabled |
|
port | 2 |
| disabled |
|
port | 3 |
| disabled |
|
port | 4 |
| disabled |
|
Uplink Failure Detection (UFD) information includes:
•UFD status, either enabled or disabled
•LtM status and member ports
•Spanning Tree status for LtM ports
•LtD status and member ports
Information Menu 59