HP xw460c Blade manual Debugging options, ARP cache options

Page 168

Debugging options

Command: /maint/debug

[Miscellaneous Debug

Menu]

tbuf

- Show

MP trace buffer

snap

- Show

MP snap (or post-mortem) trace buffer

clrcfg

- Clear all flash configs

 

 

 

The Miscellaneous Debug Menu displays trace buffer information about events that can be helpful in understanding switch operation. You can view the following information using the Debug Menu:

Events traced by the management processor (MP)

Events traced to a buffer area when a reset occurs

If the switch resets for any reason, the management processor (MP) trace buffer is saved into the snap trace buffer area. The output from these commands can be interpreted by HP technical support.

The following table describes the Miscellaneous Debug Menu options:

Table 188 Miscellaneous Debug Menu options

Command

Usage

 

 

tbuf

Displays the management processor trace buffer. Header information similar to the following is shown:

 

MP trace buffer at 13:28:15 Fri May 25, 2002; mask: 0x2ffdf748

 

The buffer information is displayed after the header.

 

 

snap

Displays the management processor snap (or post-mortem) trace buffer. This buffer contains information

 

traced at the time that a reset occurred.

 

 

clrcfg

Deletes all flash configuration blocks. The next time the switch is rebooted, it returns to the factory default

 

settings.

 

 

ARP cache options

Command: /maint/arp

[Address Resolution Protocol Menu]

find

- Show a single ARP entry by IP address

port

- Show ARP entries on a single port

vlan

- Show ARP entries on a single VLAN

addr

- Show ARP entries for switch's interfaces

dump

- Show all ARP entries

clear

- Clear ARP cache

The following table describes the Address Resolution Protocol Menu options:

Table 189 Address Resolution Protocol Menu options

Command

Usage

 

 

 

find <IP address>

Shows a single ARP entry by IP address. For example,

 

192.4.17.35

 

 

 

 

port <port number>

Shows ARP entries on a single port.

 

 

 

vlan <1-4095>

Shows ARP entries on a single VLAN.

 

 

 

addr

Shows the list of IP addresses that the switch will respond to

 

for ARP requests.

 

 

 

dump

Shows all ARP entries.

 

 

 

clear

Clears the entire ARP list from switch memory.

 

 

 

 

 

 

NOTE: To display all ARP entries currently held in the switch, or a portion according to one of the options listed on the menu above (find, port, vlan, dump), see the “ARP information” section of the “Information Menu” chapter.

Maintenance Menu 168

Image 168
Contents HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Page Contents Statistics Menu Configuration Menu 111 Index Command line interface Connecting to the switch IntroductionAdditional references Establishing a console connectionSetting an IP address Telnet GbE2c Ethernet Blade Switch IP addressEstablishing a Telnet connection Establishing an SSH connectionAccessing the switch # ssh user@GbE2c Ethernet Blade Switch IP addressIdle timeout Typographical conventions AaBbCc123Main Menu Menu summaryGlobal commands DelayTraceroute host name IP address max-hops msec Command line history and editing Telnet hostname IP address portCommand line interface shortcuts Command stackingCommand abbreviation Tab completionConfiguring Simple Network Management Protocol support # /cfg/sys/access/snmp disableread onlyread/writeMain# /cfg # /cfg/sys/ssnmp/rcommwcommSetting passwords Changing the default administrator passwordSystem# apply System# save Changing the default user password Changing the default operator password Information Menu Menu overviewSystem Information Menu SNMPv3 Information MenuAdminsha SNMPv3 USM User Table informationComm V1v2onlySNMPv3 Access Table information SNMPv3 View Table informationSNMPv3 Group Table information SNMPv3 Community Table informationPrefix SNMPv3 Target Address Table information SNMPv3 Target Parameters Table informationCommand /info/sys/snmpv3/notify NameTag V1v2trapv1v2trap SNMPv3 Notify Table informationSec Level SNMPv3 dump System information Show last 100 syslog messages System user informationCfg/sys/access/user/uid command Layer 2 information8021x Stp FDB information menu Find MAC address VlanPort port number Link Aggregation Control Protocol information Show all FDB informationLacp dump 802.1x information Port Auth Mode Authenticator PAE StateCommand /info/l2/stp Spanning Tree informationCurrent Root Path-CostPriority bridge HelloRapid Spanning Tree and Multiple Spanning Tree information Designated portDesg 8017 P2P2,Edge Desg 8018Disabled DSB Common Internal Spanning Tree information Disabled DSB Trunk group informationDiscarding Disc , Learning LRN , Forwarding FWD , or Vlan information Layer 2 general informationLayer 3 information Route information Find IP addressGw IP address If IP addressShow all IP Route information Command /info/arp/dump IP address Flags MAC address ARP informationShow all ARP entry information VlanOspf information Nbr nbr router-id A.B.C.DDbase Sumaddr Nsumadd Routes Dump Ospf general information Ospf interface informationOspf Database information menu Advrtr router-id A.B.C.D Asbrsum adv-rtr A.B.C.D Linkstateid A.B.C.DselfExt adv-rtr A.B.C.D linkstateid A.B.C.Dself Nw adv-rtr A.B.C.D linkstateid A.B.C.DselfOspf route codes information Routing Information Protocol informationRIP Routes information RIP user configuration IP informationIgmp multicast group information Command /info/l3/vrrp Vrrp information Igmp multicast router port informationVrrp information QoS information 802.1p informationQoS Menu 8021p Show QOS 802.1p information 8021pACL information Rmon Information MenuRmon history information IntervalRmon alarm information Command /info/rmon/eventRmon event information Link status information Command /info/port Port Tag Rmon Pvid Port informationVLANs Command /info/geaport Logical Port GEA Port0-based GEA Unit Uplink Failure Detection Enabled LtM status Down MemberLogical Port to GEA Port mapping Uplink Failure Detection informationCommand /info/dump Information dumpMenu information Ntp clearUfd clear Port Statistics Menu Authenticating 802.1x statisticsAuthSuccessesWhile Bridging statistics BackendNonNakResponsesFromSupplicant Ethernet statistics Dot3StatsFCSErrors Dot3StatsInternalMacTransmitErrorsDot3StatsSingleCollisionFrames Dot3StatsMultipleCollisionFramesInterface statistics Internet Protocol IP statistics Link statisticsPort Rmon statistics Layer 2 statistics FDB statisticsLacp statistics Layer 3 statisticsArp clear Clrigmp 1- 4095 allGEA Layer 3 statistics menu GEA Layer 3 statisticsIP statistics L3 bucket for An IP address DumpRoute statistics ARP statisticsDNS statistics Icmp statisticsTCP statistics UDP statistics Command /stats/l3/ospf Igmp Multicast Group statisticsOspf statistics menu Ospf stats MenuOspf global statistics Tx ls Updates Nbr changeTimers Kickoff Vrrp statisticsCommand /stats/l3/rip Management Processor statisticsRIP statistics Packet statisticsAllocs 10ad41e8/10ad5790Access Control List ACL statistics menu CPU statisticsACL statistics Snmp statistics Only NTP statistics Command /stats/dump Uplink Failure Detection statisticsStatistics dump Number of times LtM link in BlockingConfiguration Menu Saving the configuration Viewing, applying, reverting, and saving changesViewing pending changes Applying pending changesSystem configuration RemindersSystem host log configuration Line to endBannr 1-80 characters Host IP addressSecure Shell Server configuration Console disableenableLog featureall enabledisable Radius server configuration Command /cfg/sys/radiusIntrval Sshport TCP port numberTACACS+ server configuration Telnet enabledisable Port TCP port numberNTP server configuration System Snmp configurationDlight disableenable Command /cfg/sys/ssnmpSNMPv3 configuration Name 1-64 charactersCharacters User Security Model configuration V1v2 disableenableSNMPv3 View configuration Name 1-32 charactersTree 1-32 characters Mask 1-32 charactersView-based Access Control Model configuration SNMPv3 Group configurationUsmsnmpv1snmpv2 Level NoAuthNoPrivauthNoSNMPv3 Community Table configuration Usmsnmpv1snmpv2 UnameDel Deletes the vacmSecurityToGroup entry Cur SNMPv3 Target Address Table configuration SNMPv3 Target Parameters Table configurationAddr transport Address ip Port transportSNMPv3 Notify Table configuration Snmpv1snmpv2csnmp ModelSystem Access configuration Management Networks configurationUser Access Control configuration User ID configurationUseroperadmin Name Port configuration Https Access configurationAccess enabledisable Name 1-64 characters none Port link configuration Temporarily disabling a portLayer 2 configuration 802.1x configurationPort ACL/QoS configuration 802.1x Global configuration Mode forceUnauthautoforce-auth 802.1x Port configuration Reauth onoffMode rstpmstp RevCommon Internal Spanning Tree configuration Bridge parameter menuPort parameter menu 4095Cist bridge configuration Cist port configurationSpanning Tree configuration Edge disableenableCost Link autop2psharedBridge Spanning Tree configuration Spanning Tree port configuration Cur Display current port Spanning Tree parametersForwarding Database configuration Static FDB configurationFastfwd disableenable Trunk configuration MAC address Vlan portClear mac MAC AddressVLAN 1-4095 Port port numberAll Add port numberIP Trunk Hash configuration Layer 2 IP Trunk Hash configurationLink Aggregation Control Protocol configuration Lacp Port configuration Vlan configurationTimeout shortlong Mode offactivepassiveLayer 3 configuration Port numberList of port numbers IP interface configuration Addr IP addressMask IP subnet mask IP Static Route configuration Default Gateway configurationAddress Resolution Protocol configuration IP Forwarding configurationNetwork Filter configuration Dirbr disableenableRoute Map configuration Ap AS number AS number ASLp 0-4294967294 none IP Access List configuration Autonomous System Path configurationMetric 1-4294967294none Action permitdenyRouting Information Protocol configuration RIP Interface configuration Open Shortest Path First configuration RIP Route Redistribution configurationAdd 1-32 1-32all Remove 1-32 1-32allOsfp Area Index configuration Default 1-16777215 12noneMd5key 1-255 characters Redist fixedstaticripOspf Summary Range configuration Auth nonepasswordmd5Areaid IP address Type transitstubnssaOspf Interface configuration Mask IP address maskKey key stringnone Mdkey 1-255noneOspf Virtual Link configuration Key passwordNbr IP address Ospf Host Entry configuration Ospf Route Redistribution configurationRem 1-32 1-32 ... all Export 1-16777215 12noneIgmp configuration Ospf MD5 Key configurationIgmp snooping configuration Aggr disableenableFastlv 1-4095 disableenable Srcip IP addressIgmp static multicast router configuration Igmp filtering configurationAdd port number 1-4095 FilterIgmp filtering port configuration Igmp filter definitionRange IP multicast address IP Multicast addressBootstrap Protocol Relay configuration Domain Name System configurationVirtual Router Redundancy Protocol configuration Vrrp Virtual Router configurationPreem disableenable Vrrp Virtual Router Priority Tracking configuration Vrrp Virtual Router Group configurationVrs disableenable Ifs disableenableVrrp Virtual Router Group Priority Tracking configuration Vrrp Interface configuration Vrrp Tracking configurationPassw password Quality of Service configuration Access Control configurationQoS 802.1p configuration Access Control List configuration Egrport port numberAction permitdenysetprio Stats edACL Ethernet Filter configuration ACL IP Version 4 Filter configurationACL TCP/UDP Filter configuration Sport 1-65535 port maskFlags value 0x0-0x3f ACL Meter configuration ACL Re-mark configurationEnable ed CirACL Re-mark In-Profile configuration ACL Re-mark In-Profile Update User Priority configurationACL Re-mark Out-of-Profile configuration Remote Monitoring configuration ACL Packet Format configurationACL Group configuration Rmon history configuration Ifoid 1-127 charactersOwner 1-127 characters Rmon event configuration Rmon alarm configurationDescn 1-127 characters Type nonelogtrapbothPort mirroring Rlimit -2147483647 to2147483647 Flimit -2147483647 toUplink Failure Detection configuration Port-based port mirroringAdd mirrored port inoutboth Rem mirrored portFailure Detection Pair configuration Link to Monitor configurationAddport port number Remport port numberSaving the active switch configuration Link to Disable configurationDump Addport port number Remport port numberRestoring the active switch configuration Command /cfg/gtcfg FTP/TFTP server filenameConfiguration# gtcfg FTP/TFTP server filename Operations Menu Operations-level port optionsReset Reauth Operations-level port 802.1x optionsOperations-level Vrrp options Updating the switch software image Downloading new software to the switchSelecting a software image to run AddressUploading a software image from the switch Selecting a configuration blockBoot Options# ptimg Boot Options# confResetting the switch Accessing the IscliBoot Options# reset Boot Options# curMaintenance Menu System maintenance options Forwarding Database optionsFlags new Nvram flags word as 0xXXXXXXXXDebugging options ARP cache optionsIP Route Manipulation options Igmp Multicast Group optionsBroadcastmartian Igmp Snooping options Igmp Mrouter optionsUuencode flash dump FTP/TFTP system dump putClearing dump information Panic command Command /maint/panicConfirm dump and reboot y/n y Unscheduled system dumpsIndex