Troubleshooting Alarms
Attr. | Description | Recommended Action | ||
Code | ||||
|
|
| ||
AMQS | Audit Message Queue Size; a count of | Check the load on the | ||
| audit messages waiting in the queue to be | there have been a significant | ||
| committed to the database. | number of transactions this may | ||
| Alarms are based on the queue being over | be normal and will resolve itself | ||
| a specified threshold. During heavy loads | over time. | ||
| the queue can go over 10,000 or even | If the alarm persists, view a chart | ||
| 50,000, but at that level it should be | of the queue size. If the number | ||
| closely monitored. | continues increasing without ever | ||
|
|
| decreasing, contact HP technical | |
|
|
| support. | |
|
|
| ||
AUMA | AMS Device Status; indicates the general | If the service indicates “DB Con- | ||
| status of the AMS service: | nectivity Error”, restart the server. | ||
| • 0 = No errors | If this does not clear the problem, | ||
| • 1 = DB Connectivity Error | contact HP technical support. | ||
|
| |||
|
|
| ||
AUME | AMS Device State; whether the device is: | If the device goes into “Standby”, | ||
| • | 0 = Offline | continue monitoring and if the | |
| • | 1 = Standby | problem persists, contact HP tech- | |
| nical support. | |||
| • | 2 = Online | ||
| If the device goes into “Offline” | |||
|
|
| ||
|
|
| and there are no known server | |
|
|
| hardware issues (server | |
|
|
| unplugged) or a scheduled | |
|
|
| downtime for the device, contact | |
|
|
| HP technical support. | |
|
|
| ||
CAID | Count of Available Ingest Destinations; | This alarms clear when underly- | ||
| nodes that accept connections for ingest- | ing issues of available LDR | ||
CAIH | ||||
ing content. | services are corrected. Ensure the | |||
| ||||
| Normally there is more than one in a grid. | DICOM (for CAID/CAQD) and | ||
| When there is only one, a warning is set; | HTTP (for CAIH/CAQH) compo- | ||
| having none is a major alarm condition. | nents of LDRs are online and | ||
|
|
| running normally. | |
CAQD | Count of Available Q/R Destinations; | |||
| ||||
| nodes accepting connections for content |
| ||
CAQH |
| |||
query and retrieve operations. |
| |||
|
| |||
| Normally there is more than one in a grid. |
| ||
| When there is only one, a warning is set; |
| ||
| having none is a major alarm condition. |
| ||
|
|
|
|
173
HP Medical Archive