Troubleshooting Alarms
Attr. | Description | Recommended Action | |
Code | |||
|
|
| |
SSTE | Storage State; an indication of the current | If the Storage State is in “Verify”, | |
| status of the component: | this may be normal operation and | |
| • | 0 = Offline | may take quite some time depend- |
| • | 1 = Standby | ing on the quantity of data. If it |
| continues over two days however, | ||
| • | 2 = Verify | |
| contact HP technical support. | ||
| • 3 = Online | ||
| If the Storage State is “Offline”, it | ||
| • | 4 = Online | can be brought Online again using |
| If the Storage State goes into Verify, this | the Configuration tab for that | |
| means it is running through the data and | device or component. | |
| verifying its data integrity; a normal |
| |
| operation. |
| |
| If the state is Online |
| |
| data cannot be stored into this LDR, but |
| |
| data can be requested and viewed. |
| |
| Standby state is a minor alarm. This is |
| |
| usually a transitory state used to step |
| |
| between online and offline or verify. |
| |
|
|
| |
SSTU | Storage Status; an indication of the status | If the Storage Status has “Insuffi- | |
| of the storage component: | cient Free Space”, there is no more | |
| • 0 = No Errors | available storage on the server; | |
| • 1 = Not Started | data ingests are redirected to other | |
| available nodes. Viewing requests | ||
| • 2 = Performing Startup Checks | ||
| can continue to be delivered from | ||
| • | 3 = Inaccessible | |
| this node. | ||
| • 4 = Crosscheck Failed | Additional storage should be | |
| • | 5 = Corrupt | added to this server. It is not |
| • 6 = Verify Location Synchronize | impacting end user functionality, | |
|
| Failed | but the alarm persists until addi- |
| • | 7 = Maximum number of failures | tional storage is added. |
| If Storage Status is any other error | ||
|
| reached | |
|
| condition, contact HP technical | |
| • 8 = Insufficient Free Space | ||
| support. | ||
| • 9 = Unknown Error | ||
|
| ||
|
|
| |
SVST | Service Status; the status of the services | This alarm clears when other | |
| component of the SSM: | alarms related to a | |
| • | 0 = Not Running | service are resolved. Track the |
| • | 2 = Running | source service alarms to restore |
| operation. | ||
|
|
| |
|
|
|
|
191