Troubleshooting Alarms
Attr. | Description | Recommended Action | |
Code | |||
|
|
| |
NNMS | Number of NMSs the device is connected | If there is no connection to an | |
| to. |
| NMS, check the network connec- |
| Connections to the NMS do not affect | tions and whether both servers | |
| client functionality, but do affect your | and services are available. If this is | |
| ability to properly monitor the system. | not a hardware related issue and | |
|
|
| the problem persists, contact HP |
|
|
| technical support. |
|
|
| |
NSCA | NMS Device Status; indicates the general | If the service indicates “DB Con- | |
| status of the NMS service: | nectivity Error”, restart the | |
| • 0 = No errors | service. If the problem persists, | |
| • 1 = DB Connectivity Error | contact HP technical support. | |
|
| ||
|
|
| |
NSCE | NMS Device State; whether the device is: | If the device goes into “Standby”, | |
| • | 0 = Offline | continue monitoring and if the |
| • | 1 = Standby | problem persists, contact HP tech- |
| nical support. | ||
| • | 2 = Online | |
| If the device goes into “Offline” | ||
|
|
| |
|
|
| and there are no known server |
|
|
| hardware issues (server |
|
|
| unplugged) or a scheduled |
|
|
| downtime for the device, contact |
|
|
| HP technical support. |
|
|
| |
NTBR | Remaining Database Space; the number | If the available space is reaching a | |
| of bytes remaining in the allocated | low threshold, you should contact | |
| database for NMS attribute data. | HP technical support to arrange | |
| Adjusting the alarm threshold allows you | for the database allocation to be | |
| to proactively manage when additional | enlarged. | |
| storage needs to be allocated. |
| |
|
|
| |
OCOR | Objects Corrupt; the number of objects | If there are several corrupt objects | |
| stored on this LDR that have been | identified, contact HP technical | |
| detected as potentially corrupt and need | support. | |
| to be investigated. | After the underlying problem is | |
| Any corrupt objects are worthy of investi- | resolved, use the Configuration | |
| gation. More than 10 indicates a critical | tab to clear the alarm. See | |
| problem. | page 165. | |
|
|
|
|
185
HP Medical Archive