Toshiba RAM-SM800BT-E Installation of Remote Controllers, 103, Precautions, Flush wall mounting

Page 106

8 ELECTRICAL WORK

Installation of Remote Controllers

Precautions

1.Low-voltage circuit provision is used for remote controller communication, and as such, the remote controller cable is subject to the low-power circuit provision of internal wiring regulations and therefore it cannot be brought into direct contact with a high- voltage AC power line, or housed in the same conduit tube as a power line.

Flush wall mounting

Remote Controller Cabling

Cabling diagram

Terminal block

for remote controller cabling of indoor unit

A

A

B

B

C

C

Remote controller cable (Local procure)

Remote controller unit or sensor part

Feed the 3-core cable (obtained locally) though the back of the remote controller and then connect to the ABC terminals.

Attach the remote controller to the wall using two suitable mounting screws (obtained locally).

3-core cable, obtained locally

Mounting screws (x 2) obtained locally

Wall surface mounting

Attach the remote controller to the wall using two suitable mounting screws (obtained locally).

Connect the 3-core cable (obtained locally) to the ABC terminals.

Make a U-shaped cut-out in the center of the top edge of the decorative cover and pass the 3-core cable though the cut-out.

3-core cable, obtained locally

Mounting screws (x 2) obtained locally

For details of cabling/installation of the remote controller, refer to the Installation Manual packaged in the remote controller.

103

Image 106
Contents Split Type Way Air Discharge Cassette Type Installation Manual Outdoor Unit --------- RAV-SM800AT-E/RAV-SM800AT-ETo Disconnect the Appliance from Main Power Supply Precautions for SafetyNew Refrigerant Air Conditioner Installation Connect the connecting cable correctlyInappropriate grounding may cause electric shock Accessory and Installation Parts Accessory and RefrigerantSelection of Installation Before installationObstacle at rear side Upper side is free Installation PlaceNecessary Space for Installation Obstacle at front side Upper side is freeSelection of Installation Installation of Outdoor UnitRefrigerant Piping Connection Optional Installation Parts Local ProcurePiping connection How to remove the front panel Knockout procedureKnockout of Pipe Cover Flaring size a Unit mm Refrigerant PipingPipe Forming/End Positioning FlaringRefrigerant Piping Tightening of Connecting PartRequirement Air Purge EvacuatingVacuum pump Evacuating Open CloseStripping length power cord and connecting cable SM560AT-E How to remove the valve coverHow to wire Electrical WorkCheck and Test Operation Final Installation ChecksSelf-Diagnosis by LED Indication Changes in the product and components New tools for R410ARemote controller Screws two pcs AccessoriesPrecautions for Safety Standard 4-way cassette panel optional partsRAV-SM560UT-E RAV-SM800UT-E Indoor unit Parts NameOutdoor unit Parts Name of Remote Controller Display sectionOperation section Correct Usage Turn on the main power switch and/or the leakage breakerPreparation Start StopPush button How to stop swinging How to set up the wind directionHow to start swinging Heat operationTimer operation Timer OperationCancel of timer operation Maintenance Hints for Economical OperationCleaning of Air Filters Cleaning of panel and air filterClean the panel and air filter with water If you do not plan to use the unit for more than 1 monthCleaning of discharge flap Be careful to the direction of the flap when mountingAIR Conditioner Operations and Performance Troubles and Causes RE-INSTALLATIONDo not install the air conditioner in the following places Be careful with noise or vibrationsInoperative Page Accessory parts and Parts to be procured locally Separate sold partsPrecautions for Safety Precautions for Safety Installation space Selection of Installation PlaceAvoid installing in the following places Advice Selection of Installation PlaceSelection of installation place Discharge direction Height list of ceiling possible to be installedExternal view Installation of hanging bolt Installation of ceiling opening and hanging boltInstallation of ceiling panel Sold separately Flexible hose Drain Piping WorkPiping/Heat insulating material Adhesive inhibitedCheck the draining Connection procedureDrain up Perform heat insulatingTightening connection Permissible Piping Length and HeatFlaring dia meter size a Unit mm Tightening torque of flare pipe connectionsGas leak check Use a vacuum pumpOpen the valve fully Thermal insulation processFor RAV-SM800AT-E model Packed valve handling precautionsSM800 type valve at gas side Be sure to connect earth wire. Grounding work Remote controller wiringCable connection Thermal insulation to cabling connecting portElectrical Work Cabling on the ceiling panelCabling diagram Remote Controller CablingCabling Test RUN How to execute a test runCase of wired remote controller Before test runConfirmation of error history TroubleshootingConfirmation and check Accessories RAV-SM560BT-E RAV-SM800BT-E Connecting duct Fan mode display Operation mode displayTest run display Unit and Auto flap button No function Operation lamp Fan mode button ButtonFilter UP/DOWN button Correct Usage Automatic Operation Auto Changeover Clear of timer operation Do not open doors and windows more often than necessary Cleaning of Return grille Clean the Return grilles with waterAIR Conditioner Operations and Performance RE-INSTALLATION Air flow changes without FAN button set to Auto mode Auto RAV-SM560BT-E RAV-SM800BT-E Precautions for Safety Precautions for Safety Selection of installation place Installation of Indoor Unit Installation procedureDimension Hanging down of indoor unitConcealed duct type Installation of Indoor UnitRestriction to installation Ledge ceiling concealed duct typeStatic pressure characteristics of each model AIR Ducting WorkConnecting method of the duct AIR Ducting WorkPoints at installation work General cautionsMounting of filter and canvas for suction port Mounting of remote controllerHanging of indoor unit For referencePiping and cautions Piping materialConnection of the drain hose 13.2 13.0 12.7 16.6 16.2 15.9 19.7 19.4 SM800 type valve at gas side Electrical Work INSTALLATION/SERVICING Tools ToolsRemote controller RAV-SM560KRT-E RAV-SM800KRT-E Display panel Name and Functions of Indicators and ControlsTemporary button Name and Operations of Indicators and Controls Louver operation button Set up temp. buttonCentral indication ON/OFF buttonPush ON/OFF button Turn on the power switchWhen restarting the operation after stop CoolingSTART/STOP button DRY OperationSTART/STOP button HOW the AIR Conditioner Works Adjusting AIR Flow DirectionAutomatic operation Temporary Operation Air filter resetCleaning of indoor unit and remote controller Temporary operationCheck before operation Cleaning the air filterClean the air filters as often as possible Open the air inlet grilleMinute protection function Heating operation characteristics Preheating operationCleaning the air inlet grille Warm air controlInoperative Problems and CausesRecheck Does not cool well or heat wellWired remote Precautions for Safety Precautions for Safety Mounting the Installation Plate Installation ProcedureInstallation Diagram of Indoor Unit When the installation plate is directly mounted on the wallGood location Bad location Case of downward pipe exit Piping and Drain Hose InstallationCase of right-side exit Piping via left-hand connectionDrain Piping Work DrainagePermissible Piping Length and Head Evacuating 100 For RAV-SM560AT-E modelAdditional refrigerant 101Add Only R410A Refrigerant to These Units Heat insulation Wiring connections Wiring between units102 103 Installation of Remote ControllersPrecautions Flush wall mountingOptions Improving System Efficiency104 Final Installation Checks 105Environment Environmental IssuesProduct maintenance 106

RAM-SM560BT-E, RAM-SM560KRT-E, RAM-SM800UT-E, RAM-SM800AT-E, RAM-SM560UT-E specifications

Toshiba has established itself as a leader in the memory module market with a range of products tailored for various computing needs. Among its offerings, the RAM-SM560AT-E, RAM-SM560UT-E, RAM-SM800KRT-E, RAM-SM800UT-E, and RAM-SM560BT-E stand out due to their advanced features, high performance, and reliable technologies.

The RAM-SM560AT-E is engineered for optimal efficiency and speed, specifically targeting the demands of modern applications. With a capacity of up to 8GB, this module leverages DDR4 technology, allowing for faster data transfers and improved energy efficiency compared to previous generations. The design focuses on low power consumption which is crucial for laptop users who seek longer battery life without compromising performance.

Next in line, the RAM-SM560UT-E offers similar capacities but is tailored with higher clock speeds. This model is particularly beneficial for gamers and professionals engaging in graphics-intensive tasks. Its enhanced throughput enables smoother multitasking and significantly reduces latency during operations that require extensive computational power.

The RAM-SM800KRT-E is a powerhouse within the lineup, boasting increased bandwidth and specifications that cater to high-end systems. Its capacity reaches up to 16GB, and it supports advanced features like dual-channel configuration, which maximizes performance by allowing simultaneous data transfer across channels. This is ideal for users working with large datasets, as it significantly accelerates processing times.

On the other hand, the RAM-SM800UT-E is designed for versatility, accommodating a broader range of devices, from ultrabooks to gaming laptops. Its emphasis on thermal management ensures reliability during extended usage. Coupled with error-correcting code (ECC) technology, it provides enhanced data integrity, making it suitable for mission-critical applications.

Lastly, the RAM-SM560BT-E is geared towards users who value balance between performance and cost. It features a robust construction and is compatible with a variety of motherboards. This makes it an excellent choice for upgrades in systems that require reliable performance without extensive investment.

In summary, Toshiba's RAM lineup, featuring the RAM-SM560AT-E, RAM-SM560UT-E, RAM-SM800KRT-E, RAM-SM800UT-E, and RAM-SM560BT-E, showcases a diverse array of memory solutions. Each model is built with cutting-edge technology, meeting the diverse demands of users ranging from casual home users to high-power gaming enthusiasts. With high capacity options, advanced data handling features, and energy-efficient designs, Toshiba continues to be at the forefront of memory technology.