Chapter 4Setting Up the Remote Connection

HP TopTools Remote Control for HP NetServers Card Setup <L> LAN Settings

<P> PPP Settings

<R> Remote Boot Settings

<F> Firmware Update Settings

<X> Exit

Figure 4-2. Main Setup Screen

The displayed value on any of the setting screens is updated as soon as an entered value is validated.

LAN Configuration

For a remote connection to the TopTools Remote Control card via LAN, the LAN Settings screen is used to set up the connector on the card. If you are not sure how to set network parameters, contact your network administrator for the correct network settings.

NOTE

The HP TopTools Remote Control card requires its own

 

unique IP address (different from the server’s IP address) since

 

it functions independently of the server on which it is

 

installed.

 

 

Press the desired letter (D, I, N, or G) on the keyboard to change one of your Local Area Network settings. An entry window pops up that allows the entry of the new value. Closing this entry window initializes the validation of the new entry. If it is valid it will be updated on the corresponding setting screen, otherwise an error message occurs. Press M to return to the Main Setup Screen.

HP TopTools Remote Control for HP NetServers - LAN Settings

<D> Enable DHCP

DHCP is DISABLED

<I> Set IP-Address

192.168.10.10

<N> Set

Netmask

255.255.255.0

<G>

Set

Gateway

127.0.0.1

<M>

Main Menu

 

 

 

 

 

Figure 4-3. Local Area Network Configuration

25

Image 31
Contents HP TopTools Remote Control User Guide Page Contents Getting the Latest Recommended Modems List 105 Page Quick Start HP TopTools Remote Control PCI Card ConnectorsSet up the remote connection see for detailed instructions Chapter Admin Introducing HP TopTools Remote Control How HP TopTools Remote Control Works Package Contents Acronyms DocumentationWho Should Use This Guide HP TopTools Remote Control Features and FunctionsManagement and Security Diagnostics Minimum Server Requirements HP TopTools Remote Control System RequirementsLAN Connection Requirements Minimum Remote Client RequirementsDial-up PPP Connection Requirements Supported Web BrowsersHardware Installation and Configuration Preparing the HP TopTools Remote Control Card Verifying and Updating the Server’s System BiosMounting the Battery Pack Connecting the Battery Pack and Cables Locating the I2C/IPMB Connector Connecting the I2C Cable to the Remote Control CardConnecting the I2C Cable to the Server Installing the TopTools Remote Control Card in the ServerAC/DC Adapter for HP TopTools Remote Control card Connecting an Optional AC/DC AdapterPlugging in the Optional AC/DC Adapter Verifying Card InstallationSelf Test Power Up Sequence Remote Connection Options Setting Up the Remote ConnectionRunning the HP TopTools Remote Control Bios Setup Program Setting Up the Remote Connection LAN ConfigurationRemote Control card’s LAN IP address PPP ConfigurationFirmware Update Configuration Remote Boot ConfigurationPreparation for Firmware Update Setting Up a LAN ConnectionRemote Client Configuration LAN Setting Up to Use an External ModemX3&c0&d0 Remote Client Configuration PPP/Dial-Up NetworkingExample Configuring Dial-Up Networking in Windows NT 10. Define the Dial-Up Server Type 11. Define TCP/IP Settings 12. Configure Script Page Logging In to HP TopTools Remote Control HP TopTools Remote Control Web Interface Software Using the HP TopTools Remote Control Web Interface Chapter Page NT Console Redirection to a Remote Client Installing pcANYWHERE32 Server Software Installing pcANYWHERE32 on the ServerConsole Redirection Over a LAN \util\pca32\us\disk1\setup.exe Configuring pcANYWHERE32 Server SoftwareYou can configure the pcANYWHERE32 host to wait for both Installing pcANYWHERE32 on the Remote Client Configuring pcANYWHERE32 Remote Client Software Installing pcANYWHERE32 Remote Client SoftwarePcANYWHERE32 Remote Control Connection Items Modem Connection LAN ConnectionFor a Modem connection Using NT Graphics Console RedirectionCustomizing Your Connection Items For a LAN connectionChapter Paging TroubleshootingProblems with Installation HP TopTools Remote Control card does not respondNo Connection TAP No message go ahead Remote Client Some of my remote control functions appear to be disabled My power control functions appear to be disabledErase all existing user account information Forgot my password and can no longer log into the cardEvent Codes Description System PowerAppendix a Post Errors Disk Drives and Controllers SCSIFLT/ Smart Scsiflt Smart SCSIFLT/ Smart DAC Scsiflt Fcarray Physical device reports a hard error Informational Critical Non-recoverable Network Interface Controllers Notification Never Paged Severity Description Other APC/UPS Critical Informational Initialization String for PPP and Numeric Paging Recommended ModemsGetting the Latest Recommended Modems List Overview What Is TFTP? Installing and Using Tftp\ttrc\us\tftpserv.exe Tftp Requirements Updating HP TopTools Remote Control FirmwareStarting the Tftp Server \tftp\public\hp\fw\ttrc\us\ttrcrom.bin Using the HP TopTools Remote Control Remote Boot Feature \ttrc\us Creating a Floppy Boot ImageInitiating a Remote Boot Using a Floppy Boot Image Examples of Remote Boot Using a Floppy Boot Image Example 1 a remote server Bios update Copydisk a x\path\diagasst.dsk Command.com Autoexec.bat Aic7870.dsk Edit.com Page Description Technical SpecificationsFeature Description Charging Battery OperationSafety Shutting Down the Card to Conserve Battery PowerLife Expectancy Battery InitializationBattery Disposal ReplacementPage As little white dashes on the circuit board LED CodesSuggested Actions Failure CodesAppendix F Page Keyboard Layouts Appendix G Software Product Limited Warranty Hardware Product Limited WarrantyRemovable Media HP Software License Agreement For Products Labeled Class B FCC Radio Frequency Emissions Statements101 For Products Labeled Class a LAN ConnectionManufacturer’s Name Canada Technical SupportOther Countries EuropeIndex Bios106 107 108