1 Introduction

LED Readout

Displays “HP” (the default) or the unit identification number

 

during normal operation, displays status information during

 

a self-test or warns of an error condition.

Chassis Keylock

The front bezel is locked to the chassis with the key lock

 

near the top of the bezel. When the bezel is in place, it

 

effectively locks the chassis door.

SCSI Device

Standard SCSI devices, such as a DAT tape drive or an

Shelves

independent hard disk drive, can be installed in the SCSI

 

device shelves.

Drive Activity

The LED lights while the drive spins up. It goes off when

(LED) Light

the drive has spun up and is idle and flashes when the drive

 

in the module is reading or writing data. If, after the drive

 

has spun up, the light remains on, the drive may be hung. If

 

you suspect the drive is hung, refer to the “Troubleshooting”

 

chapter in this manual.

Drive Power

Indicates the status of drive power and warns of an over

(LED) Light

temperature condition. The LED lights green when the disk

 

module has been fully inserted into the shelf and power is

 

good.

 

If a single drive is flashing yellow, it indicates a faulty

 

power condition. If all the drives in a cage are flashing

 

yellow, it indicates a possible over temperature condition. If

 

all the drives in a cage are flashing red, it indicates the

 

temperature has exceeded the operational range.

 

Immediately begin shut-down procedures and refer to the

 

“Troubleshooting” chapter in this manual.

Hot-Swap Disk

When locked, the key is required to remove a hot-swap disk.

Module Keylock

Only one key is needed to remove or install any disk

 

module. The key also matches the chassis keylock.

5

E nglish

Image 11
Contents HP NetServer Storage System/6 User Guide Audience Assumptions Contents Contents Regulatory Information Page Introduction Introduction Basic InstallationUnpacking the NetServer Storage System/6 Contents of the NetServer Storage System/6 PackageFront View of the Storage System Identifying Parts of the NetServer Storage System/6Nglish Scsi Self-Test Reset SwitchPower Supply Reset General Operating InstructionsContinuous Operation Power CyclingPlacement Temperature ControlSpin Up Using an Uninterruptible Power SupplyHot-Swap Disk Module Care and Relocation Cabling Storage Devices and Setting Scsi Addresses Opening the Door Removing the Bezel and Opening the Door Storage System Switch Location Setting Scsi AddressesSettings Switch FunctionsLower Cage Cabling ConfigurationsExternal Cabling Upper CageSystem or Meter Cable Accessory Scsi Port Number Meter Cable Number Description Number Cabling Diagram LabelStorage System Layout PartC14 Default Cabling Configuration Non-DuplexC11 C20Duplex Configuration Duplex ConfigurationC11 C14 Alternate Non-Duplex ConfigurationAlternate Duplex Configuration Alternate Duplex ConfigurationPage Unpacking a Hot-Swap Disk Module Installing Hardware AccessoriesInstalling Hot-Swap Storage Devices Installing Hardware Accessories Installing a New Hot-Swap Disk ModuleRemoving a Hot-Swap Disk Module Installing the Hot-Swap Disk ModuleRemoving the Hot-Swap Disk Module Installing a Scsi Device in a Scsi Device Shelf Installing Hardware Accessories Troubleshooting Procedures TroubleshootingTroubleshooting If The System Will Not Power OnIf the Scsi Devices Fail to Spin Up If the LED Readout Shows a Fan Fault FFIf the LED Readout Shows a Line Fault LF If the LED Readout Shows a Power Supply Fault PFIf the Host Cannot Communicate With the Storage System If the Hot-Swap Disk Power LEDs are Flashing Troubleshooting Tools Error MessagesNglish Page System Design, Integration and Support Service and SupportService Service and Support Information and Support When You Need ItHP NetServer Information Assistant CompuServe Discussion Forum and Library HP Support Assistant CD-ROMAutomated Fax World Wide Web and Internet FTPBulletin Board System Telephone Support HP NetServer Support NewsObtaining HP Repair and Telephone Support Ordering System Documentation Ordering HP Cables, Drive Trays and ManualsNorth America and Asia Ordering HP Cables, Drive Trays and Technical PublicationsJoining CompuServe Contacting HP Regional HeadquartersCompuServe CompuServe Europe Page Limitation of Warranty Warranty and Software LicenseNetServer Storage System/6 On-Site Limited Warranty Three Year On-Site Limited Hardware WarrantyLimitation of Liability and Remedies Warranty and Software LicenseObtaining Warranty Service Nglish Customer Responsibilities Removable Media if supplied Software Product Limited WarrantyObtaining Return Warranty Service Ninety-Day Limited Software WarrantyWarranty and Software License Notice of Warranty Claims Environment SpecificationsWeight and Dimensions Power Supply SpecificationsPage Class B Product Statement Regulatory InformationRegulatory Information Country NoticesDeclaration of Conformity Regulatory Information Póliza de Garantía Mexico Hardware Warranty StatementNotas Index BiosIndex Nglish