HP Workgroup System AWSXCIG-1A manual Enabling Telnet Access

Page 20

NOTE: The OA automatically creates user accounts for itself (prefixed with the letters OA) to provide single sign-on capabilities. Do not remove these accounts. The OA also creates iLO accounts on each blade for its own use.

3.2.4Enabling Telnet Access

1.Under the hardware model, click iLO.

2.In the body of the main window, click Web Administration to open the iLO2 utility in a new window.

NOTE: Turn off popup blocking so the window can open.

3.In the new window, click Administration.

4.In the left frame, click Access.

5.Click the control to enable Telnet Access.

6.Click Apply to save the settings.

3.2.5Setting the Power Regulator

Select an individual blade. Click the Power Management tab and make the following settings:

1.For every node except the head node, select No to Automatically Power On Server because you do not want to automatically turn on power to the node.

2.Click Submit.

3.In the left frame, click Settings.

4.Select Enable HP Static High Performance Mode.

5.Click Apply to save the settings.

6.For the head node, continue to Section 4.4. For compute nodes, return to Section 3.2.3 and repeat Section 3.2.3, Section 3.2.4, and Section 3.2.5 for each compute node.

3.2.6Configuring Smart Array

This section is for configurations containing SB40 storage blades.

Configure disks into the smart array from the remote graphics console. You must add the disk or disks to the smart array before attempting to image the node.

To set up the smart array device, click Remote Console on the virtual console page of the iLO2 Web Administrator Utility, then follow these steps:

1.Click Integrated Remote Console to open a remote console window which provides access to the graphics console virtual media and power functions.

2.In the remote console window, click Power.

3.Click Momentary Press.

4.Wait a few seconds for the power on phase to begin. Click the MB1 mouse button in the remote console window to put the pointer focus in this window so that your keyboard strokes are recognized.

5.Watch the screen carefully during the power-on self-test phase, and press the F8 key when you are prompted to configure the disks into the smart array. Select View Logical Drives to determine if a logical drive exists. If a logical drive is not present, create one.

If you create a logical drive, exit the Smart Array utility and power off the node. Do not let it try to boot up.

For more information about specific smart array configurations, see the documentation that came with your HP ProLiant server .

20 Hardware Setup

Image 20
Contents HP Workgroup System and XC Software Installation Guide Copyright 2008 Hewlett-Packard Development Company, L.P Table of Contents HP Workgroup System Specifications Thermal Stabilization Cabling IP AddressesList of Figures Enclosure Bay Numbering Example Rear ViewRemoving the Box OA IP AddressList of Tables List of Examples Modify DatabasePage About This Document Intended AudienceDocument Organization Typographic ConventionsUser input Documentation Updates and Release NotesHP Encourages Your Comments HP Workgroup System Overview HP Workgroup System Views3shows an example rear view of the HP Workgroup System Firmware Requirements Hardware Preinstallation ChecklistHardware Prerequisites Can cause problems HP c-Class BladeSystem Enclosure Components and SwitchesHardware Setup Unpack the EnclosureRemoving the Ramp and Front Cushion Gently roll the unit down the ramp. Callout 1, FigureInstalling and Starting Up the Hardware Plug the unit into a power sourceInterconnect Switch Setting Boot Order Save user informationEnabling Telnet Access Installing and Starting Up the Hardware Page Software Preinstallation Checklist Software PrerequisitesDownloading XC Software Patches Copying the XC.lic File to Your LaptopAssociating the Enclosure DVD to the Head Node Check Choose DVD Connect to the enclosure DVDPage XC Software Installation Booting the DVDBoot linux ks=hdscd0/ks.cfg Boot linux ks=hdscd0/ks.cfg pci=nommconf# ./clusterprep --enclosurebased Running the clusterprep Command# cd /opt/hptc/config/sbin Installing Patches from Your Laptop # mkdir /home/patches# cp /media/iLO2FOLDER/* /home/patches # cd /home/patches# cp /media/iLO2-FOLDER/* /opt/hptc/etc/license/XC.lic Running the discover CommandPutting the License Key File in the Correct Location # ./clusterconfig Running the clusterconfig Command# ./discover --enclosurebased --single --ic=AdminNet Example 5-2 clusterconfig Command Output Ok, Respecify Interfaces O Running the startsys Command Configuring the Snmp TrapLSF Post-Configuration Tasks Verifying LSF-HPC with SlurmVerify the dynamic resource information Follow along with the OVP command outputRunning the OVP to Verify Software and Hardware Components Nrg Command Nagios Web InterfaceCreating a Baseline Report of the System Configuration Creating a Baseline Copy of the DatabaseSetting Up Vlan Stop bits Flow controlConfirm saving to Flash y/n y Troubleshooting Unable to Manually Set IP Addresses for the iLOsChanging External IP Addresses For example Copy the file# sysstart imageandreboot Lost Connection to the iLORemoving a Bad Golden Image # siimage baseimageLost Terminal Window When in the IRC Page # spconfig Additional Software Setup Information# scontrol reconfig Page Additional Hardware Setup Information HP Workgroup System SpecificationsTable B-2 Thermal Stabilization Specification IP Addresses on a Corporate Network CablingIP Addresses Extend the Insight Display PanelFigure C-3 OA IP Address Configure sendmail Locate the section of the file that is similar to thisConfigure sendmail Glossary Network Base imageItrc NAT SMP Index LSFXC installation, 27 XC license, 24 XC patches