HP 441877-00F manual Adapter configurations

Page 49

If you are having problems with the local (client) or network operating system, contact the operating system manufacturer for assistance. If you are having problems with some application program, contact the application manufacturer for assistance. If you are having problems with any of your computer's hardware or with the BIOS, contact HP Customer Support for assistance.

Cannot change boot order

If you are accustomed to redefining your computer's boot order using the motherboard BIOS setup program, the default settings of the Boot Agent setup program can override that setup. To change the boot sequence, you must first override the Boot Agent setup program defaults. To start the Boot Agent configuration setup program, press the Ctrl+S keys during the time the initialization message appears. A configuration setup menu appears allowing you to set configuration values for the Boot Agent. If you do not press the Ctrl+S keys, the Boot Agent software proceeds with the boot process, eventually bringing up the operating system. To change your computer's boot order setting, refer to the "Configuring the Boot Agent in a pre-boot PXE or RPL environment" section.

My computer does not complete POST

If your computer fails to boot with an adapter installed, but does boot when you remove the adapter, try moving the adapter to another computer and using IBAUtil to disable the flash chip.

If this does not work, the problem may be occurring before the Boot Agent software even begins operating. In this case, there may be a BIOS problem with your computer. Contact HP Customer Support for help in correcting your problem.

Not getting a prompt to go to Boot Agent setup program

This is actually a feature of the Boot Agent product. As part of the Boot Agent's Configuration Setup Program, two of the options, Show Setup Prompt and Setup Wait Time, allow the boot process to proceed after POST without interruption by the Ctrl+S prompt (Press the Ctrl+S keys to enter the Setup Menu)

If the Show Setup Prompt has previously been set to Disabled and/or if the Setup Menu Wait Time option is set to zero seconds, the prompt does not display after POST. However, even though you are not prompted to press the Ctrl+S keys, you can still enter the configuration setup menu to customize configuration settings as follows:

Repeatedly press the Ctrl+S keys immediately after POST until the Configuration Setup Menu appears. If the Configuration Setup Menu does not appear after repeatedly pressing the Ctrl+S keys, you were likely not fast enough. In this case, reboot and try again.

While in the Configuration Setup Menu, you can restore the prompt message as follows:

If Show Setup Prompt has been set to Disabled, change it to Enabled.

If Setup Menu Wait Time is set to zero seconds, change it to any of the wait time values that exceed zero seconds. Refer to the list of possible Set Menu Wait Time values shown in the "Boot Agent configuration settings" section.

There are configuration/operation problems with the boot process

If your PXE client receives a DHCP address, but then fails to boot, you know the PXE client is working correctly. Check your network or PXE server configuration to troubleshoot the problem. Contact HP Customer Support if you need further assistance.

Diagnostics information for pre-boot PXE or RPL environments

Anytime the Configuration Setup Menu is displayed (refer to the "Configuring the Boot Agent in a pre- boot PXE or RPL environment" section), you may press the D key to display diagnostics information on the screen. This information can be helpful during interaction with HP Customer Support personnel or your IT

Adapter configurations 49

Image 49
Contents HP ProLiant Network Adapter Software and Configuration Guide Audience assumptions Contents Technical support Supported adapters and operating systems OverviewOverview Adapter driver folders in HP SoftPaq Adapter driver and software informationDocumentation in the HP SoftPaq Installing network drivers new installations InstallationUninstall HP NC-Series NetXen 10GbE drivers Downloading filesWindows 2008 drivers Adapter support on WindowsWindows 2003 drivers Windows 2008 x64 driversWindows 2003 x64 drivers Windows 2000 driversAdapter support on NetWare Adapter support on LinuxParameter Options Description Jumbo = # Warning # Bind IPX Q571ESP NET=477A35BD Syntax SPURIOUS=n Where n = 0 or Balanceinterval Probeburstsize Smpmode Firmware upgrade utility HP NC-Series NetXen Online Firmware Upgrade Utility ROM HP NC-Series 10GbE Adapters Adapter configurationsProperty Parameter Configuring multiple NC510x PCIe 10 GbE adapters Boot options Configuring multiple ports on 10GbE adaptersAdapter configurations HP NC-Series Broadcom adapters TroubleshootingHP NC-Series Broadcom adapter properties Adapter configurations HP NC-Series Broadcom and Multifunction adapter properties Adapter configurations None. Disables checksum offloading HP NC-Series Intel adapter properties HP NC-Series Intel AdaptersAdapter configurations Adapter configurations HP NC-Series Intel adapter properties Adapter configurations Adapter configurations Boot Agent Network Boot PXE Preboot Configuration Possible values Description Settings Ibautil -option Parameter Description Ibautil -ALL -WOLDISABLE Adapter configurations Adapter configurations Adapter configurations NC31xx Fast Ethernet adapter properties HP NC-Series 31xx Fast Ethernet AdaptersAdapter configurations HP NC-Series NetXen 10GbE diagnostics DiagnosticsHP NC-Series Broadcom Multifunction adapter diagnostics Diagnostics Diagnostics HP NC-Series Broadcom adapter diagnostics Page Diagnostics Diagnostics HP NC-Series Intel adapter diagnostics Diagnostics Diagnostics Technical support Free automated customer support servicesBefore you contact HP HP contact informationHP FTP Server Acronyms and abbreviations Undi Index