•D6. RPC test (D06)
This test checks the receive
HP NC-Series Broadcom adapter diagnostics
Starting the Q57DIAG.exe tests
1.Boot to DOS or the EFI shell.
2.From the DOS prompt or shell navigate to the \APPS\DIAGS\Q57 directory.
3.Type Q57DIAG.exe and press the Enter key. The diagnostic tests run automatically.
Test descriptions
The tests are divided into four groups: Register tests, Memory tests, Miscellaneous tests, and Data tests. They are identified as group A, B, C, and D.
Group A: Register tests
•A1. Indirect register test
Using indirect addressing method, this test writes increment data into the MAC Hash Register table and reads back for verification. The memory read/write is done 100 times while incrementing test data.
•A2. Control register test
Each register specified in the configuration contents are defined as read only bit and read/write bit. The test writes zero and one into the test bits to ensure the read only bits are not changed and read/write bits are changed accordingly.
•A3. Interrupt test
This test verifies the interrupt functionality. It enables interrupt and then waits for the interrupt to occur. It waits for 500ms and reports an error if it could not generate interrupts.
•A4.
This test initiates Hardware
•A5. PCI Cfg register test
This test verifies the access integrity of the PCI config registers.
Group B: Memory tests
•B1. Scratch pad test
This tests the scratch pad SRAM on board. The following tests are performed:
o Address test: Writes each address with unique increment data. Reads back data to ensure data is correct. After filling the entire data with the unique data, the program reads back data again to ensure data stays the same.
o Walking one bit test: For each address, data one is written and read back for testing. Then the data is shifted left one bit, so the data becomes two and the same test is run again. It repeats for 32 times until the test bit is shifted out of test data. The same test is repeated for the entire test range.