Editable Parameters Table (User and Installer)
Parameter Name: | Default | Parameter Value Setting | Increment |
|
|
|
|
Installer settings
Time and Date |
| (Time/date elements screen) |
|
|
|
|
|
Daylight Saving Time | Enabled | Enabled, Disabled |
|
|
|
|
|
Circulate Fan − Percentage of Time ON | 35% | 15 to 45% | 1% |
|
|
|
|
Dealer Contact Information – Name | Lennox | (Typewriter input screen) |
|
|
|
|
|
Dealer Contact Information – Address |
| (Typewriter input screen) |
|
|
|
|
|
Dealer Contact Information – Phone | 1−800−9−LENNOX | (Typewriter input screen) |
|
|
|
|
|
Dealer Contact Information – Email |
| (Typewriter input screen) |
|
|
|
|
|
Dealer Contact Information – Website | www.lennox.com | (Typewriter input screen) |
|
|
|
|
|
SYSTEM |
|
|
|
|
|
|
|
Equipment Name |
| (Typewriter input screen) |
|
|
|
|
|
Filter 1 Timer Selection | Calendar Time | Calendar Time, Run Time |
|
|
|
|
|
Filter 2 Timer Selection | Calendar Time | Calendar Time, Run Time |
|
|
|
|
|
Humidifier Pad Timer Selection | Calendar Time | Calendar Time, Run Time |
|
|
|
|
|
UV Bulb Timer Selection | Calendar Time | Calendar Time, Run Time |
|
|
|
|
|
PureAir Timer Selection | Calendar Time | Calendar Time, Run Time |
|
|
|
|
|
Smooth Setback Recovery | Disabled | Enabled, Disabled |
|
|
|
|
|
Electric Heat Control Mode | Standard | Standard, Even Heat |
|
|
|
|
|
Gas Heat Control Mode | Modulating | Staged, Modulating |
|
|
|
|
|
Autochangeover Temp Deadband | 5ºF | 3 to 9ºF | 1ºF |
|
|
|
|
Max Heat Setpoint | 90ºF | 40 to 90ºF | 1ºF |
|
|
|
|
Min Cool Setpoint | 60ºF | 60 to 99ºF | 1ºF |
|
|
|
|
Heat/Cool Stages Locked In | Disabled | Enabled, Disabled |
|
|
|
|
|
table continued on next page
Page 25 | icomfortt Touch Screen 7−Day Programmable Thermostat |