Lennox International Inc Gas Units, G61MP Series Units In. w.g High Low Cfm Watts 2720 1385

Page 50

Blower Performance Data

G61MP−60C−110 PERFORMANCE (Less Filter)

 

Air Volume / Watts at Different Blower Speeds

Air Volume / Watts at Different Blower Speeds

External

Bottom Return Air, Side Return Air with Optional RAB

Single Side Return Air − Air volumes in bold require field

Return Air Base, Return Air from Both Sides or Return

fabricated transition to accommodate 20 x 25 x 1 in. air

Static

Air from Bottom and One Side.

 

 

 

filter in order to maintain proper air velocity.

 

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium−

Medium−

 

 

 

 

Medium−

Medium−

 

 

in. w.g.

High

Low

High

Low

High

Low

High

Low

 

 

 

 

 

 

 

 

 

 

cfm

Watts

cfm

Watts

cfm

Watts

cfm

Watts

cfm

Watts

cfm

Watts

cfm

Watts

cfm

Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.00

2720

1385

2410

1090

2055

935

1620

710

2625

1350

2310

1080

1885

885

1515

700

0.10

 

1355

 

1075

 

885

 

735

 

1330

 

1060

 

865

 

700

2665

2385

2025

1730

2570

2325

1910

1575

0.20

2585

1315

2350

1015

2030

865

1680

690

2410

1305

2285

1035

1930

845

1620

690

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.30

2505

1275

2290

990

2025

840

1695

675

2425

1265

2230

990

1925

825

1635

675

0.40

2435

1250

2235

940

2030

830

1695

660

2335

1220

2175

950

1910

810

1640

660

0.50

2350

1205

2170

930

1975

790

1735

665

2270

1195

2120

935

1895

785

1640

640

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.60

2255

1185

2100

895

1915

765

1720

650

2170

1155

2045

885

1860

765

1630

630

0.70

 

1150

 

840

 

730

 

635

 

1130

 

855

 

730

 

610

2160

2005

1865

1680

2110

1950

1795

1590

0.80

 

1090

 

825

 

710

 

610

 

1090

 

820

 

705

 

580

2020

1905

1810

1625

2035

1885

1745

1540

0.90

 

1050

 

795

 

675

 

590

 

1055

 

780

 

680

 

565

1910

1820

1705

1540

1900

1760

1665

1470

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES − All air data is measured external to unit without filter (not furnished − field provided).

G61MP−60C−111 PERFORMANCE (Less Filter)

 

Air Volume / Watts at Different Blower Speeds

Air Volume / Watts at Different Blower Speeds

External

Bottom Return Air, Side Return Air with Optional RAB

Single Side Return Air − Air volumes in bold require field

Return Air Base, Return Air from Both Sides or Return

fabricated transition to accommodate 20 x 25 x 1 in. air

Static

Air from Bottom and One Side.

 

 

 

filter in order to maintain proper air velocity.

 

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium−

Medium−

 

 

 

 

Medium−

Medium−

 

 

in. w.g.

High

Low

High

Low

High

Low

High

Low

 

 

 

 

 

 

 

 

 

 

cfm

Watts

cfm

Watts

cfm

Watts

cfm

Watts

cfm

Watts

cfm

Watts

cfm

Watts

cfm

Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.00

2475

1305

2275

1010

1800

870

1425

680

2460

1355

2210

1045

1850

860

1435

670

0.10

2395

1260

2215

980

1850

850

1495

675

2395

1320

2170

1010

1850

830

1490

660

0.20

 

1220

 

945

 

830

 

665

 

1270

 

965

 

810

 

650

2340

2165

1860

1535

2280

2115

1875

1525

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.30

2255

1205

2085

915

1855

805

1545

655

2225

1250

2075

940

1835

785

1530

640

0.40

 

1160

 

880

 

780

 

645

 

1210

 

905

 

760

 

626

2165

2000

1820

1540

2150

2005

1800

1535

0.50

 

1140

 

845

 

755

 

625

 

1155

 

885

 

740

 

620

2055

1920

1780

1535

2050

1935

1760

1555

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.60

1995

1120

1845

825

1720

725

1485

605

1975

1140

1835

845

1660

705

1480

595

0.70

1880

1075

1760

800

1680

710

1470

595

1870

1110

1745

810

1620

685

1440

575

0.80

1795

1060

1640

755

1595

680

1415

570

1760

1065

1645

770

1510

655

1370

550

0.90

1680

1020

1530

725

1505

645

1345

550

1635

1025

1545

740

1415

620

1295

530

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES − All air data is measured external to unit without filter (not furnished − field provided).

Page 50

Image 50
Contents Installation Instructions Table of ContentsFront View Side View G61MP Unit Dimensions − inches mmTOP View TOP CAP Glass AssemblyG61MP Parts Arrangement Sight BlowerInstallation Safety InformationDirect Vent Installation NON−DIRECT Vent G61MP Gas FurnaceUse of Furnace as Construction Heater General Combustion, Dilution & Ventilation AirEquipment in Confined Space − ALL AIR from Inside Equipment in Confined Space − ALL AIR from Outside Installation − Setting EquipmentEquipment operation Side View Setting EquipmentFront View END ViewUpflow Applications Refer to Engineering Handbook for additional informationFront View Furnace FrontFurnace Locations Bottom Leveling Bolt Setting an Upflow UnitLeveling Bolt NON−COMBUSTIBLE Floor Opening SizeAdditive Base Floor Opening Size Side ViewINTAKE/EXHAUST Connection Support Frame Drain PAN Blower Access PanelTypical Horizontal Ceiling Application Intake Pipe Exhaust Pipe GAS ConnectorMIN Raised Platform Condensate Line Service Platform Filters Pipe & Fittings SpecificationsPiping and Fittings Specifications Duct SystemOutdoor Termination Kits and Corresponding Equivalencies Model DIAVent Piping Guidelines Minimum Vent Pipe Lengths Maximum Vent Pipe LengthsJoint Cementing Procedure MAX Plug Plastic strapping or a large wire tieVenting Practices TrapTypical Exhaust Pipe Connections Transition Direct Vent applications where combustion air is takenFrom indoors and flue gases are discharged outdoors Sweep ELL Intake Debris Screen Page Inside Corner Detail Inches 305mm or 12 in mmUS Installations1 Canadian Installations2 Direct Vent Roof Termination KIT Exhaust Pipe Termination Size ReductionG61MP TOP View Wall Ring KIT with Straight IntakeFront View Using Existing Chimney ANGLE−CUT in Direction G61MP Direct Vent ApplicationSide View NON−DIRECT Vent Wall Ring Termination G61MP NON−DIRECT Vent Application Using Existing ChimneyCondensate Piping −RINGS CAP HI/LO Screws Condensate AssemblyCoupling CLEAN−OUT Access Vent Nipple TEEGas Piping Furnace Isolate GAS ValveHorizontal Applications Possible Gas Piping Configerations GAS Pipe Capacity − FT3/HR kL/HRElectrical Precautions and ProceduresInterior MAKE−UP BOX Installation Electrostatic Discharge ESDTypical G61MP Field Wiring Diagram Heat / 2 Cool Cut Intact OFF Cut IntactTWO−STAGE Integrated Control Board = Error Code Recall H= 24V Humidifier Output L= do not USEDIP Switches Function Integrated Control Board DIP Switch Settings and Jumpers Typical G61MP Wiring Diagram Unit Start−Up For Your Safety Read Before OperatingIntegrated Control Board White Rodgers 36E Series GAS Valve Honeywell VR8205 Series GAS ValveIf the appliance will not operate, follow the instructions Gas Pressure AdjustmentUrning Off Gas to Unit and call your service techni High Altitude Information Order TWO EachOther Unit Adjustments Carbon Monoxide Poisoning HazardPage Blower Performance Data 270In. w.g High Low Cfm Watts 2840 1450 In. w.g High Low Cfm Watts 2720 1385 In. w.g High Low Cfm Watts 2730 1465 Heating Sequence of Operation Service Electrical SHOCK, Fire Or Explosion HazardPage Planned Service + Y Ignition Control Board Diagnostic CodesFlash Code Status / Error Description Troubleshooting Heating Sequence of Operation On NextHeating Sequence of Operation Thermostat Calls for Heat Status LED − HeartbeatU1.40 microamps Or Heat Demand is SATISFIED. a Five Troubleshooting Cooling Sequence of Operation Cooling Sequence of OperationContinuous LOW Speed FAN Sequence of Operation Troubleshooting Continuous Fan Sequence of OperationRepair Parts List G61MP Start−Up & Performance Check List Heat Anticipator Setting? Thermostat Level?Vent Pipe Sizing Worksheet − LP/Propane High Fire Manifold PressureRequirements for Commonwealth of Massachusetts LY BELOW. Keep Clear of ALL OBSTRUC- Tions
Related manuals
Manual 8 pages 10.79 Kb

G61MP Series Units, Gas Units specifications

Lennox International Inc. has established itself as a leader in the heating and cooling industry, and its G61MP Series Gas Units stand as a testament to the company's commitment to innovation and energy efficiency. These gas units are specifically designed for residential applications and are recognized for their reliability, performance, and advanced technology.

One of the main features of the G61MP Series is its variable speed motor, which offers significantly enhanced comfort over traditional single-stage gas units. This technology allows for precise temperature control and improved humidity management. By adjusting its speed according to the heating demand, the unit minimizes temperature fluctuations, leading to a more consistent indoor climate.

Another notable characteristic of the G61MP Series is its ECM blower motor, which operates quietly and efficiently. This motor not only reduces energy consumption but also enhances the overall comfort of the home by providing a steady flow of warm air without the disruptive noise often associated with traditional gas units.

The G61MP Series units are designed with a focus on energy efficiency, boasting an impressive Annual Fuel Utilization Efficiency (AFUE) rating. This rating indicates that these units convert a significant portion of the fuel they consume into usable heat, resulting in lower energy bills for homeowners. The units are equipped with a modulating gas valve that further optimizes fuel usage by adjusting the gas flow according to the heating needs of the home.

Safety is a paramount consideration in the design of the G61MP Series. These units are built with advanced safety features, including a self-diagnostic control system that continuously monitors the unit’s performance. This system alerts homeowners to any potential issues, allowing for proactive maintenance and ensuring the longevity of the equipment.

The G61MP Series is also designed for ease of installation and servicing. Its compact design allows for flexible placement in various home environments, while the user-friendly access panels simplify routine maintenance tasks.

In conclusion, Lennox International Inc.'s G61MP Series Gas Units deliver a combination of advanced technology, energy efficiency, and reliability, making them an excellent choice for homeowners looking to enhance their heating systems. With features designed to maximize comfort, minimize energy costs, and ensure safety, these units represent a significant advancement in residential heating solutions.