Lennox International Inc Dave Lennox Signature Collection XC17 Air Conditioner On−board link

Page 25

One−Stage

Furnace Control

ComfortSense[ 7000 Thermostats

Catalog # Y0349 or Y2081

Air Conditioner Control

 

 

 

W

L

Y2

Y1

O

DS

2C

R

DS

O

R

On−board link

 

G

L

 

Low voltage thermostat

 

wiring

3

W2

H

W1

 

 

 

DH

O

 

 

 

R

L

 

 

 

 

H

 

C

D

 

 

 

Y1

 

 

Y2

B

 

 

 

G

Y2

1

 

 

Y1

 

 

C

 

W2

 

 

W1

T

 

T

Cut on−board link (W914) (clippable wire) from DS to R for dehumidification (Optional).

1Outdoor sensor for outdoor temperature display (Optional).

R connection required for outdoor unit with Control LSOM function. Resistor Kit (Cat# 47W97) is required when

2using the ComfortSense 7000 (Y0349) with Control LSOM feature. Resistor kit not required when using ComfortSense 7000 (Y2081).

3Cut for Humiditrol Enhanced Dehumidification Accessory (EDA) applications.

Figure 10. ComfortSense® 7000 Series Thermostat

Furnace/One−Stage Air Conditioner

Page 25

XC17 SERIES

Image 25
Contents General Table of ContentsShipping and Packing List AIR ConditionerSide View Access View Unit Dimensions − Inches mm and Parts ArrangementModel Number Identification Base with Elongated LegsTypical Unit Parts Arrangement PLUMBING, Switches and Sensor ComponentsControl BOX Using Manifold Gauge SET Operating Gauge Set and Service ValvesOperating Service Valves Torque RequirementsOperating Angle Type Service Valve To Access Service PortOperating Ball Type Service Valve Reinstall Stem CapRecovering Refrigerant from Existing System RecoveringClearance on ALL Sides Minimum Clearance Above Unit New Outdoor Unit PlacementMinimum Clearance Between TWO Units Positioning ConsiderationsStabilizing Unit on Uneven Surfaces Elevating the UnitRoof Mounting Elevated Slab Mounting using Feet Extenders Outside Unit PlacementSlab Mounting at Ground Level Stabilizing Unit on Uneven SurfacesAccess Panel Removal Removing and Installing PanelsAccess and Louvered Louvered Panel InstallationRefrigerant Line SET New or Replacement Line SetLine SET Brazing Flushing the System FlushingUncased Coil Shown Line SET and Indoor Coil 1Equalizer Line Installation Sensing Bulb InstallationFlushing Line SET and Indoor Coil 2 Installing Isolation Grommets Leak Testing the SystemLine SET and Indoor Coil Leak TestEvacuating the System Evacuating2INSTALL Thermostat Size Circuit and Install DisconnectElectrical 24VAC Transformer4ROUTE High Voltage and Ground Wires 3ROUTE Control WiresTypical XC17 Wiring Main Control AGE Main Control Jumpers and TerminalsFAN Main Control Jumpers and TerminalsFlat metal jumper Field Control WiringOn−board link Gauge SET Connections for Testing and ChargingServicing Units Delivered Void of Charge Unit Start−UpIndoor Coil AirflowAction Charge METHOD? Determine by WeighRequirements Calculating System Charge for Outdoor Unit Void of ChargeSubcooling ApproachTest and Charge Method HFC−410A Temperature Fahrenheit Psig Operating and Temperature PressuresSystem Operation Test Pins Function Ambient Sensor Temperature / Resistance Range High Discharge Sensor Temperature / Resistance Range Resetting LED Alert Codes Sensor Temperature / Resistance RangeMain Control LED Alert Codes System LED Alert CodesAlert Status Compressor LED Alert Codes Detected in RUN High Pressure Switch Operation Low Pressure Switch Operation High Discharge Temperature Sensor Operation Verifying Jumper Settings J2 MaintenanceFAN Motor Control and Start UP Verifying LED Status CodesFan Motor Board Unit LED Codes LED Codes and Sequence of OperationsControl Panel Testing for External Power to Fan Control Fan Motor Test Fan Motor Surge Protection Device FAN Motor Surge ProtectionCooling Mode XC17 Start−Up and Performance ChecklistStart UP Checks Subcooling