Lennox International Inc 506510-01 Operating Gauge Set and Service Valves, Torque Requirements

Page 4

CAUTION

Physical contact with metal edges and corners while applying excessive force or rapid motion can result in personal injury. Be aware of, and use caution when working near these areas during installation or while servicing this equipment.

IMPORTANT

The Clean Air Act of 1990 bans the intentional venting of refrigerant (CFCs, HCFCs AND HFCs) as of July 1, 1992. Approved methods of recovery, recycling or reclaiming must be followed. Fines and/or incarceration may be levied for noncompliance.

IMPORTANT

This unit must be matched with an indoor coil as specified in Lennox’ Engineering Handbook. Coils previously charged with HCFC−22 must be flushed.

WARNING

Electric Shock Hazard. Can cause injury or death. Unit must be grounded in accordance with national and local codes.

Line voltage is present at all components when unit is not in operation on units with single-pole contactors. Disconnect all remote electric power supplies before opening access panel. Unit may have multiple power supplies.

Operating Gauge Set and Service Valves

These instructions are intended as a general guide and do not supersede local codes in any way. Consult authorities who have jurisdiction before installation.

TORQUE REQUIREMENTS

When servicing or repairing heating, ventilating, and air conditioning components, ensure the fasteners are appropriately tightened. Table 1 lists torque values for fasteners.

IMPORTANT

Only use Allen wrenches of sufficient hardness (50Rc − Rockwell Harness Scale minimum). Fully insert the wrench into the valve stem recess.

Service valve stems are factory−torqued (from 9 ft−lbs for small valves, to 25 ft−lbs for large valves) to prevent refrigerant loss during shipping and handling. Using an Allen wrench rated at less than 50Rc risks rounding or breaking off the wrench, or stripping the valve stem recess.

See the Lennox Service and Application Notes #C−08−1 for further details and information.

IMPORTANT

To prevent stripping of the various caps used, the appropriately sized wrench should be used and fitted snugly over the cap before tightening.

Table 1. Torque Requirements

Parts

Recommended Torque

 

 

 

Service valve cap

8 ft.− lb.

11 NM

 

 

 

Sheet metal screws

16 in.− lb.

2 NM

 

 

 

Machine screws #10

28 in.− lb.

3 NM

 

 

 

Compressor bolts

90 in.− lb.

10 NM

 

 

 

Gauge port seal cap

8 ft.− lb.

11 NM

 

 

 

USING MANIFOLD GAUGE SET

When checking the system charge, only use a manifold gauge set that features low loss anti−blow back fittings.

Manifold gauge set used with HFC−410A refrigerant systems must be capable of handling the higher system operating pressures. The gauges should be rated for use with pressures of 0 − 800 psig on the high side and a low side of 30" vacuum to 250 psig with dampened speed to 500 psi. Gauge hoses must be rated for use at up to 800 psig of pressure with a 4000 psig burst rating.

OPERATING SERVICE VALVES

The liquid and vapor line service valves are used for removing refrigerant, flushing, leak testing, evacuating, checking charge and charging.

Each valve is equipped with a service port which has a factory−installed valve stem. Figure 2 provides information on how to access and operating both angle and ball service valves.

Page 4

506510−01

Image 4
Contents Table of Contents GeneralShipping and Packing List AIR ConditionerUnit Dimensions − Inches mm and Parts Arrangement Side View Access ViewModel Number Identification Base with Elongated LegsTypical Unit Parts Arrangement PLUMBING, Switches and Sensor ComponentsControl BOX Operating Gauge Set and Service Valves Using Manifold Gauge SETOperating Service Valves Torque RequirementsTo Access Service Port Operating Angle Type Service ValveOperating Ball Type Service Valve Reinstall Stem CapRecovering Recovering Refrigerant from Existing SystemNew Outdoor Unit Placement Clearance on ALL Sides Minimum Clearance Above UnitMinimum Clearance Between TWO Units Positioning ConsiderationsStabilizing Unit on Uneven Surfaces Elevating the UnitRoof Mounting Outside Unit Placement Elevated Slab Mounting using Feet ExtendersSlab Mounting at Ground Level Stabilizing Unit on Uneven SurfacesRemoving and Installing Panels Access Panel RemovalAccess and Louvered Louvered Panel InstallationNew or Replacement Line Set Refrigerant Line SETLine SET Brazing Flushing Flushing the SystemUncased Coil Shown Line SET and Indoor Coil 1Equalizer Line Installation Sensing Bulb InstallationFlushing Line SET and Indoor Coil 2 Leak Testing the System Installing Isolation GrommetsLeak Test Line SET and Indoor CoilEvacuating Evacuating the SystemSize Circuit and Install Disconnect 2INSTALL ThermostatElectrical 24VAC Transformer3ROUTE Control Wires 4ROUTE High Voltage and Ground WiresTypical XC17 Wiring Main Control Jumpers and Terminals Main Control AGEMain Control Jumpers and Terminals FANField Control Wiring Flat metal jumperOn−board link Connections for Testing and Charging Gauge SETServicing Units Delivered Void of Charge Unit Start−UpIndoor Coil AirflowAction Weigh Charge METHOD? Determine byRequirements Calculating System Charge for Outdoor Unit Void of ChargeSubcooling ApproachTest and Charge Method Operating and Temperature Pressures HFC−410A Temperature Fahrenheit PsigSystem Operation Test Pins Function Ambient Sensor Temperature / Resistance Range High Discharge Sensor Temperature / Resistance Range Sensor Temperature / Resistance Range Resetting LED Alert CodesMain Control LED Alert Codes System LED Alert CodesAlert Status Compressor LED Alert Codes Detected in RUN High Pressure Switch Operation Low Pressure Switch Operation High Discharge Temperature Sensor Operation Maintenance Verifying Jumper Settings J2FAN Motor Control and Start UP Verifying LED Status CodesLED Codes and Sequence of Operations Fan Motor Board Unit LED CodesControl Panel Testing for External Power to Fan Control Fan Motor Test FAN Motor Surge Protection Fan Motor Surge Protection DeviceCooling Mode XC17 Start−Up and Performance ChecklistStart UP Checks Subcooling