Auxiliary controls on your Zoneline.
Auxiliary Controls—Terminal Connections
The auxiliary controls are located behind the room cabinet beneath the access cover.
1 Remove the room cabinet. See the To Remove the Room Cabinet section.
2 Remove the screw from the access cover.
3 To make wiring connections, insert the wires into the bottom of the terminals and tighten screws securely.
4 After all desired connections have been made, replace the access cover and room cabinet.
The owner is responsible for making all connections and setting the appropriate dip switches.
CAUTION:
Improper wiring may damage the Zoneline electronics. No common busing is permitted. Damage or erratic operation may result.
A separate wire pair must be run from each separate controlling switch to each individual Zoneline.
Motion Sensor
Door Sensor
External Fan
Central Desk Control
Common - Ground
White - Heater Yellow - Compressor Black - Solenoid Green - High Speed Fan Green - Low Speed Fan Red - 24 V AC only
Safety Instructions
Operating Instructions
Care and Cleaning
Tips
Motion Sensor (Obtained locally)
When connected, the wall mounted motion sensor will detect motion in the room and automatically set back the room temperature.
The door and motion sensors work together
to automatically set back the room temperature.
Troubleshooting
Consumer Support
The appropriate dip switch must be enabled.
8
Motion Sensor