Rinnai RL94E, RL75E installation manual Installation Instructions, General Instructions

Page 16

Installation Instructions

Only properly trained and qualified installers should install this appliance. The warranty may be voided due to improper installation or installation by a non-qualified installer.

Rinnai highly recommends all installers attend a product knowledge class.

For information on a Rinnai Training Course or for questions on installation call 1-800-621- 9419.

RL75e

REU-VB2528WD-US

RL94e

REU-VB2735WD-US

R98LSe

REU-VA3237W-US

R98LSe-ASME

REU-VA3237W-ASME

The VB series (RL75e and RL94e) are certified for installation in manufactured (mobile) homes.

General Instructions

Do not use substitute materials.

Use only parts certified with the appliance.

This appliance must be installed by a state qualified or licensed contractor. It is the responsibility of the person having the water heater installed to ensure the installing contractor has proper licenses and permits for installing water heaters in your location. Rinnai highly recommends that installers attend a product knowledge class to ensure customer satisfaction and warranty coverage. Failure to comply with state and local codes pertaining to water heater installations may void the warranty.

This appliance is not to be installed indoors.

A qualified installer or service technician should install the appliance, inspect it, and leak test it before use.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. If installed in a manufactured home, the installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 and/or CAN/SCA Z240 MH Series, Mobile Homes.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa) (13.84 in W.C.).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa) (13.84 in W.C.).

Follow the installation instructions and those in Care and Maintenance for adequate combustion and ventilation air.

The appliance should be located in an area where water leakage of the unit or connections will not result in damage to the area adjacent to the appliance or to lower floors of the structure. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the appliance. The pan must not restrict combustion air flow.

The flow of combustion and ventilation air shall not be obstructed. Combustion air shall not be supplied from occupied spaces.

This appliance is not suitable for use in an application such as a pool or spa heater that uses chemically treated water . (This appliance is suitable for filling large or whirlpool bath tubs with potable water.)

If a water heater is installed in a closed water supply system, such as one having a backflow preventer in the cold water supply line, means shall be provided to control thermal expansion. Contact the water supplier or local plumbing inspector on how to control thermal expansion.

Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.

Keep the air intake location free of chemicals such as chlorine or bleach that produce fumes. These fumes can damage components and reduce the life of your appliance.

For gas type conversion, contact Rinnai.

16

VB Series Outdoor LS Manual

Image 16
Contents REU-VB2528WD-US Table of Contents Specifications RL75e RL94e R98LSe R98LSe-ASMESafety Definitions Consumer Safety InformationSafety Behavior and Practices Safety Features Features Available on Temperature Controllers FeaturesDescription of Operation Operating InstructionsTemperature Controller MC-91-1US & MCC-91-1USHow to Set the Temperature Temperature Controller SettingsTemperature Options Without a Temperature Controller Setting the Sound Volume Voice PromptRe-setting the Maximum Temperature RL75 and RL94 only MCC-91 Temperature ControllerSetting the Water Volume Using the Water Smart / Bath Fill FunctionOverview Setting Controller to Mute Setting the ClockFilling the Tub Models MC-91 and MCC-91Maintenance Error Codes Code Fault RemedyCode Accessing Operating Information Trouble Shooting for Common IssuesWater Quality Flushing the Heat Exchanger Error Code LC or Circulating PumpInstallation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterGas Piping Electrical ConnectionGeneral Instructions Pipe Sizing Procedure Example Isolation Valves Installation Instructions Pressure Relief Valve Installation InstructionsPressure Relief Valve Maintenance Water PipingPressure Relief Valve Freeze ProtectionFreeze Protection When the water heater or external piping has frozenManual draining of the water heater Freeze Protection Piping KEYRecommended Piping for Basic Installation Rinnai Water HeaterRecommended Piping for Circulation Systems For this applicationFlue Terminal Clearances ANS Z21.10.3, CSA Description Canadian Installations US Installations Additional Clearances Connecting Multiple Water Heaters High Altitude InstallationsNumber Connected Accessories Necessary Water Heaters GuidelinesCanada only Temperature Controller Installation ConfigurationsLocation Cable Lengths and SizeMounting the Controller Outline of RemoteFor Your Safety Read Before Operating Operating InstructionsPressure Drop Curve Technical DataOutlet Flow Data Temperature Setting ReplacementSpace Heating PumpsDimensions Ladder Diagram for RL75e and RL94e Ladder Diagram for R98LSe and R98LSe-ASME HOTWarranty Information Limited WarrantyWhat is covered? Consumer SupportWhat will Rinnai do? How do I get service? What is not covered?Limitation on warranties State Regulations Important In the State of Massachusetts 248 CMR 4.00Ou lappel 1-866-RINNAI1 Instructions dutilisation Temp. d’eauOptions de température sans contrôleur à distance Plages de température avec un contrôleur de températureLes températures suggérées sont de Entretien Instructions générales Écartements par rapport à lappareil Fixation du chauffe-eauRaccordement électrique Tuyauterie de gaz Installations à haute altitudeInstructions générales Valve de dégagement de pression Instructions d’Installation Tuyauterie deauSoupape de sûreté Qualité de leauNiveau maximum Espacements pour terminaisons de cheminée ANS Z21.10.3, CSA Réf Description Installations Canada Installations USA Tuyauterie recommandée pour installation de base LégendeInstructions dutilisation VanneMa ualmanuelleValveDiagramme en escalier RL75e, RL94e PhaseDiagramme en escalier R98LSe, R98LSeASME B CSupport à la clientèle Informations sur la garantieQuest-ce qui est couvert ? Combien de temps dure la couverture ?Que fait Rinnai pour exercer la garantie ? Limitation sur les garantiesVB2528W VB2735W VA3237W