Rinnai RL94E, RL75E installation manual Ladder Diagram for R98LSe and R98LSe-ASME, Hot

Page 38

Ladder Diagram (for R98LSe and R98LSe-ASME)

HOT

 

 

NEUTRAL

3A(FUSE)

FROST SENSING

 

 

SWITCH

 

 

ARRESTER

 

 

ANTI-FROST HEATER

 

 

 

VARISTOR

VARISTOR

 

 

 

 

 

GND

RELAY 1

 

IGNITION

 

IG

 

SWITCHING

 

 

POWER SUPPLY

 

PG

DC170V

DC12V

E

D

DC12.6V

DC5V

DC40V

A B

WATERFLOW

A

SENSOR

WATERFLOW

QS

SENSOR

 

CIRCUIT

WATERFLOW

A

SG

CONTROLDEVICE

WATERFLOW

 

M

 

CONTROLDEVICE

 

CIRCUIT

 

BY-PASSFLOW

A

SG

CONTROLDEVICE

BY-PASSFLOW

M

CONTROLDEVICE

 

CIRCUIT

 

C

SG

 

B

A B

C

 

MODULATING

 

VALVEPOWER

 

CONTROL

 

 

CIRCUIT

 

 

SG

 

CPU

D

E

CENTRAL

 

 

PROCESSING

FAN

 

UNIT

 

 

CONTROL

 

 

CIRCUIT

 

MODULATING SOLENOID VALVE

POV

COMBUSTION FAN

FAN

BY-PASS SERVOMODEL ONLY

A RELAY 1

SG

RELAY

DRIVING

CIRCUIT

PG

A

THERMALFUSE

SV0

SOLENOID

FLAME ROD

OVERHEAT

SV1

SV2

SWITCH

 

SV3

OUTGOING WATER

THERMISTOR

HEAT EXCHANGER

THERMISTOR

AIR TEMPERATURE

THERMISTOR

INDOOR MODEL ONLY

DRIVING

CIRCUIT

B SG

THERMISTOR CIRCUIT

SG

FLAME

DETECTING

CIRCUIT

SG

GND

A B

REMOTE

CONTROLLER

CIRCUIT

SG SG

FR

REMOTE CONTROLLER

38

VB Series Outdoor LS Manual

Image 38
Contents REU-VB2528WD-US Table of Contents Specifications RL75e RL94e R98LSe R98LSe-ASMESafety Behavior and Practices Safety Features Consumer Safety InformationSafety Definitions Description of Operation Features Available on Temperature ControllersFeatures Operating InstructionsTemperature Controller MC-91-1US & MCC-91-1USHow to Set the Temperature Temperature Controller SettingsRe-setting the Maximum Temperature RL75 and RL94 only Temperature Options Without a Temperature ControllerSetting the Sound Volume Voice Prompt MCC-91 Temperature ControllerOverview Using the Water Smart / Bath Fill FunctionSetting the Water Volume Filling the Tub Setting Controller to MuteSetting the Clock Models MC-91 and MCC-91Maintenance Error Codes Code Fault RemedyCode Water Quality Trouble Shooting for Common IssuesAccessing Operating Information Flushing the Heat Exchanger Error Code LC or Circulating PumpInstallation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterGeneral Instructions Electrical ConnectionGas Piping Pipe Sizing Procedure Example Pressure Relief Valve Maintenance Isolation Valves Installation InstructionsPressure Relief Valve Installation Instructions Water PipingPressure Relief Valve Freeze ProtectionManual draining of the water heater When the water heater or external piping has frozenFreeze Protection Freeze Protection Piping KEYRecommended Piping for Basic Installation Rinnai Water HeaterRecommended Piping for Circulation Systems For this applicationFlue Terminal Clearances ANS Z21.10.3, CSA Description Canadian Installations US Installations Additional Clearances Number Connected Accessories Necessary Water Heaters Connecting Multiple Water HeatersHigh Altitude Installations GuidelinesCanada only Location Temperature Controller InstallationConfigurations Cable Lengths and SizeMounting the Controller Outline of RemoteFor Your Safety Read Before Operating Operating InstructionsOutlet Flow Data Technical DataPressure Drop Curve Space Heating Temperature SettingReplacement PumpsDimensions Ladder Diagram for RL75e and RL94e Ladder Diagram for R98LSe and R98LSe-ASME HOTWhat is covered? Warranty InformationLimited Warranty Consumer SupportLimitation on warranties How do I get service? What is not covered?What will Rinnai do? State Regulations Important In the State of Massachusetts 248 CMR 4.00Ou lappel 1-866-RINNAI1 Instructions dutilisation Temp. d’eauLes températures suggérées sont de Plages de température avec un contrôleur de températureOptions de température sans contrôleur à distance Entretien Instructions générales Écartements par rapport à lappareil Fixation du chauffe-eauRaccordement électrique Instructions générales Installations à haute altitudeTuyauterie de gaz Valve de dégagement de pression Instructions d’Installation Tuyauterie deauNiveau maximum Qualité de leauSoupape de sûreté Espacements pour terminaisons de cheminée ANS Z21.10.3, CSA Réf Description Installations Canada Installations USA Tuyauterie recommandée pour installation de base LégendeInstructions dutilisation VanneMa ualmanuelleValveDiagramme en escalier RL75e, RL94e PhaseDiagramme en escalier R98LSe, R98LSeASME B CQuest-ce qui est couvert ? Support à la clientèleInformations sur la garantie Combien de temps dure la couverture ?Que fait Rinnai pour exercer la garantie ? Limitation sur les garantiesVB2528W VB2735W VA3237W