Freeze Protection

Manual draining of the water heater

If the water heater is not going to be used during a period of possible freezing weather, it is recommended that the water inside the water heater be drained.

To manually drain the water:

1.

Shut off cold water supply and gas supply.

Hot water

2.

Turn off the temperature controller.

outlet

 

3.Disconnect the power to the water heater.

4.Open hot water drain plug at the hot water outlet.

5.Remove water filter to drain the cold water.

If an isolation kit is installed, remove the drain caps on both isolation valves and open both valves above the caps (blue and red valve handles).

To resume normal operation:

1.Confirm that all water drain plugs are removed, that the gas supply is turned off, and that all taps are closed.

2.Screw in the hot water drain plug.

3.Screw in the water filter in the cold water inlet.

If the isolation kit was used to drain the unit, replace the drain caps and close both isolation valves (blue and red valve handles).

4.Open the cold water supply.

5.Open a tap and confirm that water flows, and then close.

6.Turn on the power.

7.After confirming that the temperature controller is off, turn on the gas supply.

8.Turn on the temperature controller.

Hot water

Water

drain plug *

filter

Cold water inlet

*Use a wrench or other tool to unscrew the hot water drain plug.

Running a low volume of water through the water heater to prevent freezing

If the temperature exceeds the ability of the water heater to freeze protect itself, or if power is lost, the following steps may prevent the water heater and external piping from freezing. (Units connected with MSA or EZConnect should be drained to prevent freezing if not in use.)

1.Turn the water heater off.

2.Close the gas supply valve.

3.Reduce the flow to about 0.1 gal/min or to where the stream is about 0.2 inches thick.

ON! COLD

HOT

0.1gal/min or about 0.2 inch thick

When the water heater or external piping has frozen

1.Do not operate the water heater if it or the external piping is frozen.

2.Close the gas and water valves and turn off the power.

3.Wait until the water thaws. Check by opening the water supply valve.

4.Check the water heater and the piping for leaks.

22

VB Series Outdoor LS Manual

Image 22
Contents REU-VB2528WD-US Table of Contents Specifications RL75e RL94e R98LSe R98LSe-ASMESafety Definitions Consumer Safety InformationSafety Behavior and Practices Safety Features Description of Operation Features Available on Temperature ControllersFeatures Operating InstructionsTemperature Controller MC-91-1US & MCC-91-1USHow to Set the Temperature Temperature Controller SettingsRe-setting the Maximum Temperature RL75 and RL94 only Temperature Options Without a Temperature ControllerSetting the Sound Volume Voice Prompt MCC-91 Temperature ControllerSetting the Water Volume Using the Water Smart / Bath Fill FunctionOverview Filling the Tub Setting Controller to MuteSetting the Clock Models MC-91 and MCC-91Maintenance Error Codes Code Fault RemedyCode Accessing Operating Information Trouble Shooting for Common IssuesWater Quality Flushing the Heat Exchanger Error Code LC or Circulating PumpInstallation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterGas Piping Electrical ConnectionGeneral Instructions Pipe Sizing Procedure Example Pressure Relief Valve Maintenance Isolation Valves Installation InstructionsPressure Relief Valve Installation Instructions Water PipingPressure Relief Valve Freeze ProtectionFreeze Protection When the water heater or external piping has frozenManual draining of the water heater Freeze Protection Piping KEYRecommended Piping for Basic Installation Rinnai Water HeaterRecommended Piping for Circulation Systems For this applicationFlue Terminal Clearances ANS Z21.10.3, CSA Description Canadian Installations US Installations Additional Clearances Number Connected Accessories Necessary Water Heaters Connecting Multiple Water HeatersHigh Altitude Installations GuidelinesCanada only Location Temperature Controller InstallationConfigurations Cable Lengths and SizeMounting the Controller Outline of RemoteFor Your Safety Read Before Operating Operating InstructionsPressure Drop Curve Technical DataOutlet Flow Data Space Heating Temperature SettingReplacement PumpsDimensions Ladder Diagram for RL75e and RL94e Ladder Diagram for R98LSe and R98LSe-ASME HOTWhat is covered? Warranty InformationLimited Warranty Consumer SupportWhat will Rinnai do? How do I get service? What is not covered?Limitation on warranties State Regulations Important In the State of Massachusetts 248 CMR 4.00Ou lappel 1-866-RINNAI1 Instructions dutilisation Temp. d’eauOptions de température sans contrôleur à distance Plages de température avec un contrôleur de températureLes températures suggérées sont de Entretien Instructions générales Écartements par rapport à lappareil Fixation du chauffe-eauRaccordement électrique Tuyauterie de gaz Installations à haute altitudeInstructions générales Valve de dégagement de pression Instructions d’Installation Tuyauterie deauSoupape de sûreté Qualité de leauNiveau maximum Espacements pour terminaisons de cheminée ANS Z21.10.3, CSA Réf Description Installations Canada Installations USA Tuyauterie recommandée pour installation de base LégendeInstructions dutilisation VanneMa ualmanuelleValveDiagramme en escalier RL75e, RL94e PhaseDiagramme en escalier R98LSe, R98LSeASME B CQuest-ce qui est couvert ? Support à la clientèleInformations sur la garantie Combien de temps dure la couverture ?Que fait Rinnai pour exercer la garantie ? Limitation sur les garantiesVB2528W VB2735W VA3237W