Rinnai RL94E, RL75E installation manual Dimensions

Page 36

Dimensions

 

 

 

 

 

 

RL75e, RL94e

R98LSe, R98LSe-ASME

B

A

 

 

B

A

 

 

C

D

C D

 

 

 

 

 

 

 

 

K

 

 

E

 

 

E

I G

 

 

 

 

F H

 

H

J

G I

 

 

F

 

 

 

J

 

DIM

DESCRIPTION

RL75e

R98LSe

 

 

RL94e

R98LSe-ASME

 

 

in (mm)

in (mm)

 

 

 

 

 

A

Width

14 (355.6)

18.5

(470)

 

 

 

 

B

Depth

9.9 (251.1)

9.3 (230.5)

 

 

 

 

 

 

C

Height - Unit

22.9

(582)

23.6

(600)

 

 

 

 

 

D

Height - with brackets

25.0 (634.2)

25.2

(640)

 

 

 

 

E

Hot Water Outlet - from wall

3.8 (97.6)

4.5 (115)

 

 

 

 

 

F

Hot Water Outlet - from center

4.3 (110)

2.4

(61)

 

 

 

 

 

G

Cold Water Inlet - from wall

3.0 (76.6)

3.9

(99)

 

 

 

 

 

 

H

Cold Water Inlet - from center

1.1

(27)

2.0

(52)

 

 

 

 

I

Gas Connection - from wall

4.2 (105.6)

2.4 (61.2)

 

 

 

 

 

J

Gas Connection - from center

3.5

(89)

4.3 (110)

 

 

 

 

 

 

 

From base to gas connection

1.6

(40)

1.6

(40)

 

 

 

 

 

 

K

From base to cold connection

2.0

(50)

2.0

(50)

 

 

 

 

 

 

 

From base to hot connection

1.6

(41)

1.6

(41)

 

 

 

 

 

 

36

VB Series Outdoor LS Manual

Image 36
Contents REU-VB2528WD-US Table of Contents Specifications RL75e RL94e R98LSe R98LSe-ASMEConsumer Safety Information Safety DefinitionsSafety Behavior and Practices Safety Features Features Available on Temperature Controllers FeaturesDescription of Operation Operating InstructionsTemperature Controller MC-91-1US & MCC-91-1USHow to Set the Temperature Temperature Controller SettingsTemperature Options Without a Temperature Controller Setting the Sound Volume Voice PromptRe-setting the Maximum Temperature RL75 and RL94 only MCC-91 Temperature ControllerUsing the Water Smart / Bath Fill Function Setting the Water VolumeOverview Setting Controller to Mute Setting the ClockFilling the Tub Models MC-91 and MCC-91Maintenance Error Codes Code Fault RemedyCode Trouble Shooting for Common Issues Accessing Operating InformationWater Quality Flushing the Heat Exchanger Error Code LC or Circulating PumpInstallation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterElectrical Connection Gas PipingGeneral Instructions Pipe Sizing Procedure Example Isolation Valves Installation Instructions Pressure Relief Valve Installation InstructionsPressure Relief Valve Maintenance Water PipingPressure Relief Valve Freeze ProtectionWhen the water heater or external piping has frozen Freeze ProtectionManual draining of the water heater Freeze Protection Piping KEYRecommended Piping for Basic Installation Rinnai Water HeaterRecommended Piping for Circulation Systems For this applicationFlue Terminal Clearances ANS Z21.10.3, CSA Description Canadian Installations US Installations Additional Clearances Connecting Multiple Water Heaters High Altitude InstallationsNumber Connected Accessories Necessary Water Heaters GuidelinesCanada only Temperature Controller Installation ConfigurationsLocation Cable Lengths and SizeMounting the Controller Outline of RemoteFor Your Safety Read Before Operating Operating InstructionsTechnical Data Pressure Drop CurveOutlet Flow Data Temperature Setting ReplacementSpace Heating PumpsDimensions Ladder Diagram for RL75e and RL94e Ladder Diagram for R98LSe and R98LSe-ASME HOTWarranty Information Limited WarrantyWhat is covered? Consumer SupportHow do I get service? What is not covered? What will Rinnai do?Limitation on warranties State Regulations Important In the State of Massachusetts 248 CMR 4.00Ou lappel 1-866-RINNAI1 Instructions dutilisation Temp. d’eauPlages de température avec un contrôleur de température Options de température sans contrôleur à distanceLes températures suggérées sont de Entretien Instructions générales Écartements par rapport à lappareil Fixation du chauffe-eauRaccordement électrique Installations à haute altitude Tuyauterie de gazInstructions générales Valve de dégagement de pression Instructions d’Installation Tuyauterie deauQualité de leau Soupape de sûretéNiveau maximum Espacements pour terminaisons de cheminée ANS Z21.10.3, CSA Réf Description Installations Canada Installations USA Tuyauterie recommandée pour installation de base LégendeInstructions dutilisation VanneMa ualmanuelleValveDiagramme en escalier RL75e, RL94e PhaseDiagramme en escalier R98LSe, R98LSeASME B CSupport à la clientèle Informations sur la garantieQuest-ce qui est couvert ? Combien de temps dure la couverture ?Que fait Rinnai pour exercer la garantie ? Limitation sur les garantiesVB2528W VB2735W VA3237W