Rinnai RL94E, RL75E installation manual Electrical Connection, Gas Piping, General Instructions

Page 18

Electrical Connection

The water heater must be electrically grounded in accordance with local codes or in the absence of local codes with the most recent edition of the National Electrical Code, ANSI/NFPA 70. In Canada, all electrical wiring should be in accordance with local codes and the Canadian Electrical Code, CSA C22.1 Part 1. Do not rely on the gas or water piping to ground the water heater. A screw is provided in the junction box for the grounding connection.

The water heater requires 120 VAC, 60 Hz power from a properly grounded circuit.

A disconnect switch must be provided and installed for the incoming 120 VAC power. It should be a type that is suitable for outdoor use. Check the National Electrical Code, ANSI/NFPA 70 and your local codes for a proper switch type to use in your area.

The wiring diagram is located on the Technical Sheet attached to the inside of the front cover.

Ground

Connection

Screw

Gas Piping

General Instructions

A manual gas control valve must be placed in the gas supply line to the Rinnai water heater. A union can be used on the connection above the shut off valve for the future servicing or disconnection of the unit.

Check the type of gas and the gas inlet pressure before connecting the Rinnai water heater. If the Rinnai water heater is not of the gas type that the building is supplied with, DO NOT connect the water heater. Contact the dealer for the proper unit to match the gas type.

Check the gas supply pressure immediately upstream at a location provided by the gas company. Supplied gas pressure must be within the limits shown in the Specifications section.

Before placing the appliance in operation all joints including the heater must be checked for gas tightness by means of leak detector solution, soap and water, or an equivalent nonflammable solution,

as applicable. (Since some leak test solutions, including soap and water, may cause corrosion or stress cracking, the piping shall be rinsed with water after testing, unless it has been determined that the leak test solution is non-corrosive.)

Always use approved connectors to connect the unit to the gas line. Always purge the gas line of any debris before connection to the water heater.

The gas supply line shall be gas tight, sized, and so installed as to provide a supply of gas sufficient to meet the maximum demand of the heater and all other gas consuming appliances at the location without loss of pressure.

Any compound used on the threaded joint of the gas piping shall be a type which resists the action of liquefied petroleum gas (propane / LPG).

Refer to an approved pipe sizing chart if in doubt about the size of the gas line.

18

VB Series Outdoor LS Manual

Image 18
Contents REU-VB2528WD-US Table of Contents Specifications RL75e RL94e R98LSe R98LSe-ASMEConsumer Safety Information Safety DefinitionsSafety Behavior and Practices Safety Features Description of Operation Features Available on Temperature ControllersFeatures Operating InstructionsTemperature Controller MC-91-1US & MCC-91-1USHow to Set the Temperature Temperature Controller SettingsRe-setting the Maximum Temperature RL75 and RL94 only Temperature Options Without a Temperature ControllerSetting the Sound Volume Voice Prompt MCC-91 Temperature ControllerUsing the Water Smart / Bath Fill Function Setting the Water VolumeOverview Filling the Tub Setting Controller to MuteSetting the Clock Models MC-91 and MCC-91Maintenance Error Codes Code Fault RemedyCode Trouble Shooting for Common Issues Accessing Operating InformationWater Quality Flushing the Heat Exchanger Error Code LC or Circulating PumpInstallation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterElectrical Connection Gas PipingGeneral Instructions Pipe Sizing Procedure Example Pressure Relief Valve Maintenance Isolation Valves Installation InstructionsPressure Relief Valve Installation Instructions Water PipingPressure Relief Valve Freeze ProtectionWhen the water heater or external piping has frozen Freeze ProtectionManual draining of the water heater Freeze Protection Piping KEYRecommended Piping for Basic Installation Rinnai Water HeaterRecommended Piping for Circulation Systems For this applicationFlue Terminal Clearances ANS Z21.10.3, CSA Description Canadian Installations US Installations Additional Clearances Number Connected Accessories Necessary Water Heaters Connecting Multiple Water HeatersHigh Altitude Installations GuidelinesCanada only Location Temperature Controller InstallationConfigurations Cable Lengths and SizeMounting the Controller Outline of RemoteFor Your Safety Read Before Operating Operating InstructionsTechnical Data Pressure Drop CurveOutlet Flow Data Space Heating Temperature SettingReplacement PumpsDimensions Ladder Diagram for RL75e and RL94e Ladder Diagram for R98LSe and R98LSe-ASME HOTWhat is covered? Warranty InformationLimited Warranty Consumer SupportHow do I get service? What is not covered? What will Rinnai do?Limitation on warranties State Regulations Important In the State of Massachusetts 248 CMR 4.00Ou lappel 1-866-RINNAI1 Instructions dutilisation Temp. d’eauPlages de température avec un contrôleur de température Options de température sans contrôleur à distanceLes températures suggérées sont de Entretien Instructions générales Écartements par rapport à lappareil Fixation du chauffe-eauRaccordement électrique Installations à haute altitude Tuyauterie de gazInstructions générales Valve de dégagement de pression Instructions d’Installation Tuyauterie deauQualité de leau Soupape de sûretéNiveau maximum Espacements pour terminaisons de cheminée ANS Z21.10.3, CSA Réf Description Installations Canada Installations USA Tuyauterie recommandée pour installation de base LégendeInstructions dutilisation VanneMa ualmanuelleValveDiagramme en escalier RL75e, RL94e PhaseDiagramme en escalier R98LSe, R98LSeASME B CQuest-ce qui est couvert ? Support à la clientèleInformations sur la garantie Combien de temps dure la couverture ?Que fait Rinnai pour exercer la garantie ? Limitation sur les garantiesVB2528W VB2735W VA3237W