Omega Speaker Systems iSE-TC manual Adjustable Chart, Fla sh Archive

Page 26

4.3.2 Adjustable Chart

 

 

• Click on

Chart

 

, the following page (Figure 4.8) should appear. The Java™ Applet

 

 

graph displays

 

Temperature values which can be charted across the full span or within

 

any narrow range (such as 20 to 30ºC). The time-base can display one minute, one

 

hour, one day, one week, one month or one year.

 

 

 

If a blank screen appears without any “java application running” or image of a

 

 

“Java logo”, please verify you have the latest Java Runtime Environment

 

 

 

 

installed and configured according to the instructions (refer to Section 4.3.1.1).

 

 

If you do not have Java Runtime Environment, you may download it from our

 

 

website or contact the Customer Service Department nearest you.

 

 

 

 

 

 

 

Archives_Inactive:

 

 

 

 

 

 

 

1minute or 1hour

 

 

 

 

 

 

 

Archives_Enable:

 

 

 

 

 

User selectable

 

1Day, 1Week, 1Month, or 1Year

 

 

 

 

 

Title

Archives_Done:

 

 

 

temperature units: F or C

charting starts for the “time” selected in the

 

 

 

 

 

 

 

lower pull down menu

Actual Input 1

Flash Archive

 

 

 

 

 

 

Actual Input 2

http://192.168.1.200

Flash Archive

 

 

 

Temperature

 

 

 

 

 

 

Temperature

 

 

67.8

SP1_L(below)=044.5 F

SP1_H (above)=090.0 F

77.7

 

 

User selectable

Input 1:

F

 

Archives_Done

Input 2:

122

Setpoint boundary

122

 

 

 

 

 

 

temperature range

 

 

 

 

 

 

 

 

Number of degrees

 

 

 

 

 

 

 

 

 

per division

9.0/Div

 

 

 

 

 

 

9.0/Div

 

based on

 

 

 

 

 

 

 

temperature range

 

 

 

 

 

 

 

 

 

User selectable

32

 

 

 

 

 

 

32

 

temperature range

03/01/2008

09:42:10

1 Day

(1 Hour/Div)

03/02/2008

09:42:10

 

 

 

 

 

1 Minute

 

 

 

 

 

 

 

 

 

1 Hour

Main Menu

 

 

 

 

 

 

 

1 Week

 

 

 

 

Start Time

 

 

1 Day

 

 

 

 

 

End Time

 

 

1 Year

 

 

 

 

 

 

 

 

1 Month

 

 

 

 

 

 

User selectable time base

 

 

 

 

 

 

 

1 minute, 1 hour, 1 day,

 

 

 

 

 

 

 

1 week, 1 month, or 1 year

Figure 4.8 Adjustable Chart

 

 

 

 

 

 

 

 

 

To avoid any miscommunications when downloading the stored data from the “Chart” page, it is strongly recommended to let the recording run for a minimum of 3 minutes if the time interval is 10 seconds (from “Configuration” page), and 15 minutes if the time interval is 1 minute.

22

Image 26
Contents User’s Guide Page Dhcp DNS List of Figures ISE and iLD Big Display on the Ethernet NetworkFeatures Part Introduction Page ISE and iLD Big Display on the Ethernet Network Part 2 Hardware Wall MountingDIP Switches DIP Switch LocationParts of the iSE Unit Parts of iSE UnitDisassembly Instruction Opening the UnitNetwork Communication Interfaces 1 10Base-T RJ-45 Pinout Relay and I/O Contact Wiring ConnectionsCrossover Cable Wiring Running on Battery Power Battery and S5 Jumper LocationFlash Memory Format Data Record TestEthernet MAC Address Network Configuration 3.1 Network ProtocolsPart Subnet Mask DhcpDNS SectionExample C\Telnet 192.168.1.200 Default IP AddressPort Number Testing the Connection Part OperationsIConnect Software ISERVER Home Setting a New IP Address over the Network Access ControlLogin and Administrator Passwords Setup and Operation Using the iSE WebPrompted for a password, as shown in Figure Read Sensor Java Runtime Environment 1.4 Setup instructions Read SensorDiagnostics Java Runtime Environment 1.5 5.0 Setup instructionsAccessing iSE units using the internet Adjustable Chart Fla sh ArchiveRetrieving Data from Flash OptionDhcp can be enabled by setting the dip switch number #2 RTC is set, and recording is in progress Configuration#1 RTC is not set and Flash Card is empty #4 RTC is not set and the Flash Card is not emptyReal Time Clock Flash Recording SettingsRemote Access Tunneling MegaBytes Flash Card 22 Kbytes Used SpaceConfiguration/Device Setup Temperature 1 and TemperatureInput 2 Status Unlatch, Latch, Clear Latch, Chart SP Flash RecordingConfiguration Configuration Input Contact Closure Terminal ServerConfiguration Remote Access 12 Sensor Parameters Temperature Sensor ParametersTA71.34F TA72.48F TD-1.19F TA71.34FTA72.48FTD-1.19FTelnet Setup HTTPget ProgramHTTPget using Port Srhc SrtcSrtf SrhfWhere HTTPget and ARP to setup Device IP AddressArp -s 192.168.1.200 00-03-34-00-06-b6 15 ARP Commands and Responses ARP ProtocolILog Software 16 iLog Software Logging DataInstallation Mail Notifier SoftwareEmail Setup OptionsDevice Setting and Configuration Device setup requires 19 iSE Mail Notifier Device SettingPart Specifications Sensor Specifications Thermocouple InputEnvironmental PowerInterfaces PackagingNetwork Interface Part Approvals Information CE Approval Measurement CategoryAppendix Aglossary Appendix BIP Address Or Dotted Notation Appendix CIP NetmaskAddress Class Mask Binary Value Mask Decimal Value Mask Dotted Notation Mask Binary Mask BitsDec Binary Appendix D Hex Ascii Chart Dec BinaryAscii Char No Parity No parityChar Equiv Appendix D Ascii Chart ContinuationDec Hex Ctrl Key Ascii Control Codes Definition Appendix E ILog Error Messages Error # Description Page Page WARRANTY/DISCLAIMER Shop on line at omega.com