Omega Speaker Systems iSE-TC manual Appendix E ILog Error Messages Error # Description

Page 56

 

Appendix E

iLog Error Messages

 

Error #

 

Description

 

Note

 

 

 

 

 

 

-8003

 

User stopped logging readings.

 

 

 

-10005

 

Failed to find the iSE.

 

Ethernet cable is disconnected,

 

 

 

 

 

 

iSE is powered off, connections

 

 

 

 

 

 

across the firewall require longer

 

 

 

 

 

 

“connection to socket time out”

 

 

-10006

 

Windows socket was closed.

setting.

 

 

 

 

 

 

-10007

 

Windows socket error.

 

Wrong IP or wrong Port number

 

 

 

 

 

 

was used.

 

 

-10008

 

The iSE failed to respond to a request.

Wrong IP or wrong Port number

 

 

 

 

 

 

was used.

 

 

-10011

 

Response came empty.

 

No data was sent.

 

 

-10012

 

Device responded with

 

Possibly the iLog is configured for

 

 

 

 

"Serial Time Out" string.

 

wrong product model.

 

 

-10014

 

Terminal Server Mode when the Port is 1000.

Try Port 2000 in iLog configuration.

 

 

-15100

 

Error on obtaining the temperature reading.

Possibly the iLog is configured for

 

 

 

 

 

 

wrong product model.

 

 

 

 

 

 

 

 

52

Image 56
Contents User’s Guide Page Dhcp DNS List of Figures ISE and iLD Big Display on the Ethernet NetworkFeatures Part Introduction Page ISE and iLD Big Display on the Ethernet Network Part 2 Hardware Wall MountingDIP Switches DIP Switch LocationParts of the iSE Unit Parts of iSE UnitDisassembly Instruction Opening the UnitNetwork Communication Interfaces 1 10Base-T RJ-45 Pinout Relay and I/O Contact Wiring ConnectionsCrossover Cable Wiring Running on Battery Power Battery and S5 Jumper LocationFlash Memory Format Data Record TestEthernet MAC Address Network Configuration 3.1 Network ProtocolsPart Dhcp DNSSubnet Mask SectionExample C\Telnet 192.168.1.200 Default IP AddressPort Number Testing the Connection Part OperationsIConnect Software ISERVER Home Setting a New IP Address over the Network Access ControlLogin and Administrator Passwords Setup and Operation Using the iSE WebPrompted for a password, as shown in Figure Read Sensor Java Runtime Environment 1.4 Setup instructions Read SensorDiagnostics Java Runtime Environment 1.5 5.0 Setup instructionsAccessing iSE units using the internet Adjustable Chart Fla sh ArchiveRetrieving Data from Flash OptionDhcp can be enabled by setting the dip switch number Configuration #1 RTC is not set and Flash Card is empty#2 RTC is set, and recording is in progress #4 RTC is not set and the Flash Card is not emptyFlash Recording Settings Remote Access TunnelingReal Time Clock MegaBytes Flash Card 22 Kbytes Used SpaceConfiguration/Device Setup Temperature 1 and TemperatureInput 2 Status Unlatch, Latch, Clear Latch, Chart SP Flash RecordingConfiguration Configuration Input Contact Closure Terminal ServerConfiguration Remote Access 12 Sensor Parameters Temperature Sensor ParametersTA71.34F TA72.48F TD-1.19F TA71.34FTA72.48FTD-1.19FTelnet Setup HTTPget ProgramHTTPget using Port Srtc SrtfSrhc SrhfWhere HTTPget and ARP to setup Device IP AddressArp -s 192.168.1.200 00-03-34-00-06-b6 15 ARP Commands and Responses ARP ProtocolILog Software 16 iLog Software Logging DataInstallation Mail Notifier SoftwareEmail Setup OptionsDevice Setting and Configuration Device setup requires 19 iSE Mail Notifier Device SettingPart Specifications Sensor Specifications Thermocouple InputPower InterfacesEnvironmental PackagingNetwork Interface Part Approvals Information CE Approval Measurement CategoryAppendix Aglossary Appendix BIP Address Appendix CIP Netmask Address Class Mask Binary Value Mask Decimal ValueOr Dotted Notation Mask Dotted Notation Mask Binary Mask BitsAppendix D Hex Ascii Chart Dec Binary AsciiDec Binary Char No Parity No parityChar Equiv Appendix D Ascii Chart ContinuationDec Hex Ctrl Key Ascii Control Codes Definition Appendix E ILog Error Messages Error # Description Page Page WARRANTY/DISCLAIMER Shop on line at omega.com