High End Systems SHOWGUN user manual Operational, Environmental, Electrical, Fuses, Power

Page 17

CHAPTER 1

Product Overview

Operational

Pan: 420°

Tilt: 216°

Zoom Range: 9°–18°

Fixture Output: 100,000 Lumens

Environmental

Maximum ambient temperature, (Ta): 45° C (113° F)

Minimum Distance to Flammable Objects: 4m (13.1 ft)

Maximum exterior surface temperature: 150° C (302° F)

Minimum Focus Distance to non-flammable object: 3 m (10 ft)

Electrical

Power

Input Rating: 200-240 VAC

Fixture Rated Power: 2800 W

Power Consumption: 14 Amps at 208 V, 11 Amps at 240V

WARNING!

Class 1 equipment - This equipment must be earthed.

Fuses

Fuse

Fuse Type and Rating

Manufacturer

Part Number

Motor Power Supply Input

2.5A, 250V, Slow Blow

Littelfuse

90403027EF

 

 

 

 

Motor Power Supply Output

5A 250V, Slow Blow

Littelfuse

90403012EF

 

 

 

 

2-phase Driver Boards

2.5A, 125V, Slow Blow SMF

Littelfuse

90402016EF

 

3-phase Pan and Tilt Board

 

 

 

 

LED Control Board

5A, 125V, Slow Blow SMF

Littelfuse

90412027EF

 

 

 

 

Lamp Power Supply Input

20A, 250V, Very Fast

Bussmann

90403030EF

 

 

 

 

SHOWGUN® User Manual

5

Image 17
Contents High End Systems, Inc , All Rights Reserved Americas Contacting High End SystemsAccording to ISO/IEC Guide 22 and EN45104 Declaration of ConformityProduct Modification Warning Important Safety InformationInjury and/or damage to equipment FCC Information Safety SymbolsLimited Warranty Warranty InformationReturning an Item Under Warranty for Repair FreightVii Viii Table of Contents Showgun Menu System Fixture Programming Maintenance and Troubleshooting Fixture Showgun FeaturesChapter Product Overview Construction OperationPart Description Part Number Related Products and AccessoriesMechanical SpecificationsOperational PowerEnvironmental ElectricalLithoPattern Specifications Lamp SpecificationsCable and Connector Specifications Unpacking the Fixture Chapter Setup and ConfigurationInstalling a Power Cord Cap Vatic Fitter Heads Information Danmark Installing a Line Cord Cap U.K. OnlyMounting the Fixture Truss Mounting Mounting the Fixture UprightLinking Showgun Fixtures Cable ConnectorsFixture Homing Powering On the FixtureConnecting to the Link Shutting Down the Fixture Setting the DMX Start ChannelShowgun Display Chapter Showgun Menu SystemNavigating the Menu System Error Message Display Display in Menu Locked ModeNavigational Basics Fixture Software Version DMX Start ChannelExiting the Menu System Unlocking the Menu SystemMenu Map Level Option/Setting Description/NotesFollowing sensors LevelMenu System Options Setting DMX Start ChannelDMX Address Menu Determining DMX Start Channel AssignmentType Used per Channel Link Fixture FixtureChannel Location Fixture Channels Start Pan/Tilt Swap Factory Default SettingsSet Parameters Menu Tilt Invert Pan InvertLamp Life Limit Data Loss TimeoutTest Options Menu Fixture Mode MenuCrossloading Fixture Software Homing the FixtureDisplay Test Motor Setup Copying the Boot CodeEncoder Disable Code Menu Lamp StateSensor Status Menu Information MenuUnique Number DMX Values MenuFixture Hours Temperatures MenuLamp HR/Strike Reset Fixture Hours ResetLamp Hours Lamp StrikesNext DMX Channel Display ErrorsModule Version DMX Programming Overview Chapter Fixture ProgrammingFull Speed verses MSpeed Control DMX Programming OptionsChannel Function Showgun DMX ParametersPan and Tilt CMY Color Color MixingTri Color Color Function DescriptionRGB Color LED Tracking SystemLED Tracking Functions LED Tracking System DimmingShutter/Lamp Function Shutter Channel Shutter and Lamp EffectsMacros Zoom and FocusMSpeed Motor Speed Control Setting Description Control SettingsChapter Fixture Component Replacement Chapter Maintenance and TroubleshootingFuse Fuse Location and Access Symptom of Failure Replacing FusesFuse Fuse Type and Rating Manufacturer HES Part Number Replacement FusesReplacing the Lamp Chapter Driver Boards Phase BoardsPan Board Phase BoardReplacing Lithopatterns Achromatic Lens Cleaning the Showgun FixtureMicrofresnel Lens Filter ReflectorProduction Homing Accessing the Bulk HeadsIris and Gobo Bulk Head Soft Edge Flag Bulk HeadFlag Calibration Example Connect dimmer flag motors directly to 2-phase driverCalibrate the flags AdjustmentChapter Power Board Connection Functions Supply Powered TroubleshootingPower Supply Board LED States State Problem? DescriptionAppendix a MSpeed Conversion Table Dec Appendix B Important Safety Information Appendix B Important Safety Information Appendice C Importantes Informations Sur La Sécurité Warnung Zum Schutz Vor Brandgefahr Anhang C Wichtige Hinweise Für Ihre SicherheitWarnung Zum Schutz Gegen Gefährliche Körperströme Warnung Zum Schutz Vor VerletzungenAdvertencia Para Protección Continua Contra Incendios Apéndice C Información Importante De SeguridadAvvertenza Per Prevenire Incendi Appendice C Importanti Informazioni Di SicurezzaAvvertenza Per Prevenire Le Scosse Elettriche Avvertenza Per Non Ferire Ad Altre PersoneVigtig Sikkerhedsinformation Appendix B Important Safety Information